AD-104 is a kind of high-precision,economical and practical screening audiometer.Can use for hearing test when fitting high-end hearing-aid and visiting service.And also use for hearing condition test of school, industrial and mining enterprises,army, fahrschule, rehabilitation centre and deaf training etc.
AD-104 can conduct all standard hearing-aid test, Language hearing test and all special test that depend on structure.
The design of AD-104 is on the base of a advanced 24 pixels digital signal processing,can produce high quality signal,and own prodigious refractivity.
Easy operation process.Can show the current condition clearly.button and selector are all type of low noise.The voice level,frequency and other information could be showed on the display clearly.Language input signal can be provided by internal or external microphone.It has a function:when testing language hearing, masking signal and language signal can be provided to the ears at the same time,that is noise language testing.
There have 3 output option:standard earphone(AC),bone conduction(BC) and special output(SF),can be connected to free area megaphone or inserted earphone.
AD-104 can calibrate multiple types of earphone at the same time.
AD-104 can be use as mobile devices,and also as desktop.
AD-104 use keyboard to intall and operate,so it very easy to handle.
Display:
There are two output LED on both side of the disply,when the selected detection signal transfer to corresponding ear,the screen would show.During the audio detection,the up line of the display would show the strength that provide to left or right ear by dBHL ration.
When testing,the test ear would showon the disply. Test frequency would show in the middle of the screen.If cover the opposite ear,it will show in the opposite side.
AD-104 Technical Index
Channel:Two independent channel
Frequency: Air conduction; Bone conduction and free sound field 11 standard frequency,125-8000Hz,bone conduction 250-6000Hz,error less than 1%.
Masking:Pure tone test ;ipsilateral white noise
Sound pressure range:
8000-10
Output interface:TDH39 or plug-in Air conduction earphone71 Bone conduction earphone free sound field
Standard fountion: Pure tone test.Provide continuantpulse voice and warble tone
Normal: Press INT to start sound stimulate
Inversion: Press INT to stop sound stimulate.5dB step and 5dB step continuous attenuation,1DB error.
Have microphone
Distortion: Air conduction: <2.5%; Bone conduction: <5%
Operation Environment: Temperature + 10 C, air temperature 30%-90%,
Air pressure:860hPa -- 1060hPa
Preheating time: Less than 10 minutes
Size : 45cm*30cm
Weight : 1775g
Power source : 230VAC, 50Hz
Maximum power : 60VA
Executive standard : Audiometer producing standard: EN60645-1, EN60645-2,EN60645-4 and ANSI S3.6-1996
Safety standard : EN 60601-1,level 1 class B EN 60601-1-2EN 60601-1-4
Standard accessory: TDH39 Air conduction earphone,B71 Bone conduction earphone(reprovision),responder, power line.
Hp series hearing aid programmer and the usb interface of pc computer constitute a complete hp system. After set up hp system, you can read and write the data of hearing aid through the hearing aid software that provide by manufacturers.
GZ-0702 audiometer is a computer control hearing test equipment that combine by several functional modules. It¡¡¥s a Microcomputer hearing evaluation tool which develop base on hearing test and the Acoustic requirements of hearing-aid fitting.
GZ-0702 audiometer use for pure tone test,be suitable for hospital ENT diagnose and hearing-aid fitting,or clinical/family and outer ambulant hearing test.
Test could proceed by TDH39 air conduction.test signal including pure tone,pluse voice and warble tone.
GZ-0702 audiometer provide 11 air conduction test frequency point, frequency range from 125Hz to 8KHz,dB HL from 0 to 110.
GZ-0702 audiometer also provide 11 bone conduction test frequency point, frequency range from 125Hz to 8KHz,dB HL from 0 to 70(the standard is from 250Hz to 6000Hz).
All of the test data result could be automatic switch to pure tone audiogram and calculate patient¡¡¥s PTA value automatically.
All of the test data result could be automatic switch to pure tone audiogram and calculate patient¡¡¥s PTA value automatically.
The structure of audiometer make it convenient for service,and autotest make it easy to debugging and annual calibration.
PC computer interface: USB
Operating system: WindowXP
Driver:WindowXP own
Technical parameters
Output:Air conduction/bone conduction
Masking; NB/WN/SN/PN
Maximun HL air conduction/bone conductin: 110DB/70DB
Test frequency: 0.125
Noise/square wave
Attenuation step length: IdB+5dB
External Printer :Please purchase by yourself
Sound field calibration: Internal/ external voice/ tone
Earphone:Medical headset
Monitor : Internal/ external
Structure:Metal case
Size : W.D.H20*14.5*3.5cm
Weight (including TDH39 Air conduction earphone and power source):2Kg
Outer packing : Aluminic box
Pure tone digital audiometer GZ0702
Advantage:1. Elegant appearance,must connect computer,can rewrite name of organization,name of client and consultant,contact way.
2.Generate audiogram and automatic generate PTA
3.Can save client information on the computer.
4. High-performance, portable, small and exquisite, Hardware combined with computer software, achieve digitalize hearing test.