Application
SDTGA408 can be used to determine the air dried basis moisture and total moisture in coal, coke, petroleum, minerals, and solid biomass fuels and so on.
Standards
ISO11722 Solid mineral fuels Hard coal Determination of moisture in the general analysis test sample by drying in nitrogen
ASTM D5142-09 Standard Test Method for Proximate Analysis of the Analysis Sample of Coal and Coke by Instrumental Procedures
GB/T212-2008 Standard Test Method for Proximate Analysis of Coal
GB/T212-2007 Determination of Total Moisture in Coal
Features
1. Wide Application & High Efficiency
The moisture tester is applicable to all types of coal. Single test: 18 samples for inherent moisture or 9 samples for total moisture. And, it supports continuous batch analysis.
2. Arbitration Analysis
Light-wave heating enables fast and uniform heating. with nitrogen ventilating device and unique gas-saving design, the gas consumption is low while precision and accuracy is high. The test result meets the requirements of arbitration analysis.
3. High Automation
Sample weighing is automatic, and the weights are displayed in the computer screen. During the testing, real-time weight is shown on the computer. After heating, the result is calculated automatically.
4. Easy Operation
The moisture tester supports data processing, forms statistics, and printing. Network and balance connection are available.
with CAN bus interface, several moisture testers can be controlled by a single PC. Data can be transferred to PC via serial port.
Standard Layout
SDTGA408 Moisture Tester/ Lenovo PC / Printer.
Descriptions:
SDS616 sulfur analyzer is used to determine the total sulfur content in coal, coke, petroleum and other combustible materials.
Conformance with standards: GB
Specifications:
Test range: 0.01%~35%
Sample weight: 50mg
Analysis time: 3~6min
Furnace temperature: 1150 celsius degree
Oxygen purity: 99.5%
Max power: 3kw
Dimensions: 860*530*380mm (sds616 only)
Net weight: 80kg
Features:
Autoloader -- up to 12 samples can be loaded at a time.
Ultra-low drift -- only start-up calibration is needed per single workday
Fast speed -- 110 seconds per sample
Sample introducing rod -- self-protective with long service time
Gas supply is based on the position of the sample rod
User-friendly windows-based software
Options:
Computer kit
Printer kit.
Dimension: 860*530*380mm
Weight: 80kg.
1.High efficiency
Sample weighing, crucible introducing, analyzing, residual weighing, crucible discarding and data management are all finished automatically by the computer. Test is conducted with high efficiency
2.Improved accuracy
Sample weighing at room/low temperature by external and internal balances, the influence caused by balance drift has been effectively reduced
3.Safe operation
Specially designed volatile matter crucible together with unique auto-sample loading mechanism to avoid the operation of replacement or removal of the crucible cover under high temperature to avoid the heat emission and hurt to the operator.
4.Operation cost saving
Gas supply by compressed air, no oxygen and nitrogen required.
5.Easy to operate and handle
easy to use windows-based operating software, after finishing the sample weighing, the operator can be free for other tasks.
easy data handling, real time data can be transmitted by internal network.
with can bus interface, several proximate analyzers can be controlled by a single PC connect with balance and network by standard interface RS232.
Dimension:845*563*596mm
Weight: 146kg.
Application:
Measuring calorific value of Coal, Coke, Fuel oil, Food, and other solid or fluid combustibles
Descriptions:
SDACM4000 Calorimeter adopts a fully-integrated circulation system for a compact footprint -- no additional heaters or coolers required. An integral water-measuring station simplifies sample preparation, and temperature is measured by PT1000 Platinum resistance to the nearest 0.0001 K to ensure test precision.
Standards: ASTM/ISO/GB
Features:
1. High precision across a wide range of ambient conditions
2. Automatic oxygen filling
3. Automatic bucket filling
4. Automatic sample ignition
5. Automatic temperature detection and result calculation
Highlights:
1. High Accuracy & Precison
2. Fully Automatic
3. Windows-based operating software
4. Stable Performance with Low User Cost Each Year
Options:
Computer kit
Printer kit
Consumables.
Export plywood case.
Application:
Measuring calorific value of coal, coke, fuel oil, food, and other solid or fluid combustibles
Standards: ASTM/ISO/GB
Description:
Sdc313 calorimeter adopts a fully-integrated circulation system for a compact footprint -- no additional heaters or coolers required. An integral water-measuring station simplifies sample preparation, and temperature is measured by pt1000 platinum resistance to the nearest 0.0001 k to ensure test precision.
Features:
1. High precision across a wide range of ambient conditions
2. Automatic oxygen filling
3. Automatic bucket filling
4. Automatic sample ignition
5. Automatic temperature detection and result calculation
Highlights:
1. Helix-tube jacket
Internal stability is secured with the aid of a helix tube within both the
Lid and the jacket wall. This enables the system with constant water
Temperature even if the ambient temperature fluctuates by 10° c
In the single period of testing.
2. Volumetric tank
3. Water purifier
Options:
Computer kit
Printer kit
Consumables.
Export plywood case.
Descriptions:
SDC311 calorimeter adopts a fully-integrated circulation system for a compact footprint -- no additional heaters or coolers required. An integral water-measuring station simplifies sample preparation, and temperature is measured by ,platinum resistance to the nearest 0.0001 k to ensure test precision.
Standards:
ASTM/ISO/GB
Features:
1. High precision across a wide range of ambient conditions
2. Automatic oxygen filling
3. Automatic bucket filling
4. Automatic sample ignition
5. Automatic temperature detection and result calculation
Highlights:
1. Helix-tube jacket
Internal stability is secured with the aid of a helix tube within both the
Lid and the jacket wall. This enables the system with constant water
Temperature even if the ambient temperature fluctuates by 10
In the single period of testing.
2. Volumetric tank
3. Water purifier
Options:
Computer kit
Printer kit
Consumables
Application:
Coal, coke, fuel oil, food, and other solid or fluid combustibles.
Export plywood case.
Descriptions:
SDAF105 ash fusion determinator automatically monitors ash cone deformation temperatures in coal ash and coke ash(IT, ST, HT, AND FT). A complete image history for all analyzed samples can be digitally archived and retrieved to make objective determinations of deformation temperatures. And the cone support is introduced into and removed out from the furnace automatically.
Standards:
ASTM/ISO/GB
Features:
1. Automatic cone support introducing and retreating;
2. A stable, permanently mounted integrated camera -- isolated from the high temperature area;
3. Manual observing of cone images from the front window of the instrument available;
4. A complete image history for all analyzed samples can be digitally archived and retrieved to make objective determinations of deformation temperatures.
Highlights
1. Light reflector - perfect gas tightness with only one hole on the furnace wall
2. Integrated camera
3. Automatic sample introducing device
Options:
Computer kit
Printer kit
Application:
Coal ash, coke ash, etc.
Dimension: 550*850*843mm
Weight: 100kg.
Descriptions:
SDS212 infrared sulfur analyzer is used to determine the total sulfur content in coal, coke, petroleum and other combustible materials.
Conformance with standards:
ASTM
ISO
GB
Features:
Autoloader -- up to 12 samples can be loaded at a time.
Ultra-low drift -- only start-up calibration is needed per single workday
Fast speed -- 110 seconds per sample
Sample introducing rod -- self-protective with long service time
Gas supply is based on the position of the sample rod
User-friendly windows-based software
Options:
Computer kit
Printer kit.
Dimension:822*604*636mm
Weight: 108kg.
Features:
1. Dual furnace configuration
2. Temperature up to 1000C
3. Atmosphere: compressed air with low user cost
4. Simultaneous sample analysis (up to 18 samples)
5. Complies with astm, and gb methodology
Conformance with standards:
ASTM
GB
Highlights:
1. Dual-furnace
Up to 54 samples can be tested in a workday (8 hours).
2. Internal and external balances
Sample residues are weighed by internal balance under the low-temperature furnace. Accuracy is improved by eliminating heat drift.
3. Autoloader
Samples are introduced into and removed out of the furnace (max 1000° c) by a manipulator to ensure safe and convenient operation.
Options:
Computer kit
Printer kit
Applications:
Coal, coke etc.
Dimension: 878 mm
Weight:149kg