Metering mode: Double-beam C-t optical structure, blazed holographic grating, photomultiplier tube detection
Wavelength range:190nm-1100nm
Resolution:better than 0.15nm
Spectro bandwidth:1.8nm
Wavelength accuracy:0.3nm(with automatic wavelength calibration device.)
Wavelength accuracy:<0.2nm
Stray light:Better than 0.05%(220nm,Nal)
Metering accuracy:0.3£¥(with NBS930D)
Metering repeatability:0.2nm
Wavelength scanning speed::Fast¡¢Normal¡¢slow
Transmittance accuracy:Better than 0.3£¥(t)(with NBS930 )
Stability:¡Ü0.004A/30min
Dimension: 540mm¡Á430mm¡Á220mm(W¡ÁD¡ÁH)
Power supply voltage:AC220V22V;frequency 50Hz1Hz supply voltage for foreign products can be customized according to customers needs)
Weight : 15kg.
Temperature control range: 7¡æ-400¡æ of room temperature (increment by 1¡æ)
Temperature control objects: column, ion chamber, thermal conductivity, sampler A, sample B, auxiliary (standby)
Temperature programming phase: five
Temperature programming rate: 0.1¡æ-40¡æ£¯min(increment by 0.1¡æ)
Flame Ionization Detector (FID)
Sensitivity : M¡Ü1¡Á10-11g/s(sample:l C16)
Optimal test result: M¡Ü5¡Á10-12g/sl.
Features:
1. Temperature measurement range: 0-40(32¨h - 104¨h)
2. Precision ¨h measurement temperature:¡à1(2¨h)
3. Measurement temperature resolution: 1(1¨h)
4. Operation temperature:0 ¨c35(32¨h-90¨h)
5. Storage temperature: 0 ¨c50(32¨h-122¨h)
6. Dimension:135¡á65¡á40mm
7. Weigh:200g
8. Power supply: 2¡áaaa(1.5v)
9. Operating time: more than 2000 times per battery
10. Automatic temperature compensation
11. Automatic shut ¨h
12. Conversion between centigrade and fahrenheit degree
13. Alarm ¨h low voltage
Propylene glycol
Range: 0~50
Accuracy: 0.1
Divisions: 0.1
Ethylene glycol
Range: 0~-50
Accuracy: 0.1
Divisions: 0.1
Battery
Range: 1.00~1.50sg
Accuracy: 0.01sg
Divisions: 0.01sg
Cleaner
Range: 0~-40
Accuracy: 0.1
Divisions: 0.1.
Main features:
It has been assessed and registered as meeting the requirements of ISO9001 and 14000.
With Italian fuel injection system
Automatically control system, digital display
Time set, automatically incinerate and ignite
Vacuum burning, fuel is diesel fuel
Can meet the requirements of the national environmental protection standard.
Low failure rate, low maintenance and running cost
Technical parameter:
Model Capacity Fuel Sampling Methods Power Power Supply
JK-MI-10 10Kg/H Diesel fuel Automatically 700W 220V/50HZ
JK-MI-20 20Kg/H Diesel fuel Automatically 900W 220V/50HZ
JK-MI-30 30Kg/H Diesel fuel Automatically 1100W 220V/50HZ
JK-MI-50 50Kg/H Diesel fuel Automatically 1800W 220V/50HZ.
Model : JK-DOL-9070A
Electrical Requirement : 220V 50Hz
Power Consumption : 1550W
Temperature Range : RT+10~200¡æ/RT+10~250¡æ
Display Resolution : 0.1¡æ
Temperature Stability : ¡À1¡æ
Temperature Uniformity : 1.5%
Shelves : 2(pcs)
Internior Dimension
(W¡ÁD¡ÁH, mm) : 400¡Á350¡Á500
Chamber Volume : 80L
Timing Range : 1~9999min.