Supplier: Ethanol /alcohol process line/machine,ethanol/alcohol turnkey project , industry fruit process machine/production line ,industry vegetable process machine/production line, industry noodle machine/production line , industry bread/cake machine/process line and so on . industry waste water treatment system process line .packing machine
Services: Our company's products, technical support, training, installation and commissioning
Features External (key-switch operated): Reset/resound/test zone lamps evacuate Silence alarm sounders Silence fault sounders Internal: One man detector test Zone isolate Revert to short-circuit: fire (no resistors in call points) External indicators: Sounder fault Battery/power supply fault Mains on Zone fire Zone fault Internal indicators: Open circuit zone fault Short circuit zone fault Zone isolated Engineer test selected Outputs: Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit) Ancillary connections for expansion modules will allow the following: Repeater panels Multiple sounder outputs Connection to landlord panel
Supplier: Surveillance cameras, solar panels, agricultural product, chemicals, energy supplies
Buyer: Digital equipment
Supplier: In line pump, split casing pump, submersible sewage pump, axial flow pump, chemical process pump, slurry pump, boiler feed pump, vacuum pump, control panel, fire fighting pump, nuclear pump
Buyer: Control panel, low pressure and high pressure motor, mechanical seal, pressure tank, diesel engine
The FK-5-1-12 Clean Agents, also known as NOVEC1230 Fire Suppression Agents, is a highly efficient and reliable hydro-fluorocarbon fire extinguishing solution. This product is designed to quickly and effectively suppress fires in various settings while being non-toxic, environmentally friendly, and safe to use. Model Number: FK-5-1-12 clean agents Product Name: NOVEC1230 Fire Suppression Agents Reliability: High Model NO.: FK-5-1-12 clean agents Application The FK-5-1-12 Clean Agents is suitable for use in various applications, including but not limited to: Commercial buildings Industrial facilities Data centers Telecommunication rooms Museums and art galleries Power generation plants Server rooms Control rooms Storage facilities
Fire guard manufactures a wide range of fire control panels and accessories. From the newly launched conventional 2-8 zone conventional control unit to the highly capable analogue addressable panels.
Control panel One installing code One (user) main code (can create duress code automatically) 8 gradable user codes Periodic test Offer testing report to alarm center automatically Peripheral eequipment With voice module Disarmed/armed by romote control. Any zone can be programmed to be the switch lock port Events record 50 event records Memory when power is cut Digital voice module rv2006v 1 piece of voice message, time lasts 20s Follow-me number is assignable Timing function Auto daily arming Auto daily test report Monitoring function Trouble data can be displayed on keypad, and also can be transmited to central station Spare battery in low power Expansion module of power supply battery in low power Siren circuit in trouble Phone line failure Loss of ac Loss of auxiliary power System clock is not set Tamper prevention Fire alarm circuit in trouble Installation All expansion modules can be connected to the system by 4-line The distance is up to 300m between module and control panel Technical data Transformer: 16.5vac 40va Standby bettery: 12v4ah/ 12v7ah Auxiliary powerfg350ma Switch lockfg250ma Siren/bell sound outputfg750ma Led keypadf]rp205kp 3 keypad emergency zones: panic([1]+[2]), fire([4]+[5]), special emergency([7]+[8]) Led indicates the user functions and the installer programing Key-press with audible feedback Trouble display Led indication: alarm, power, armedfadisarmed, bypass, ready, tamper Backlight keys Tamper is supervised Alarm by duress code Easy to use hot-keys for simple bypassing and not-ready zones display One button for quick arming One button for quick perimeter arming Up to 4 led keypads can be connected Mainboardf]rp205mb 5 zones of mainboard Special zones: zone-5 is fire zone Can be parted to 2 divisions11 types of programmable zones, 7 types of voice formats Zone terminal: nc, no, single end with resistor (2.2kf±[) Responding to various events Time to supervise is programmable Switch for power output Linkage output: nc, no, locked, or pulse Programmable output: 70ma 50 events records 8 groups of 4 gradable codes Switch output: 250ma Built-in siren driver: 750ma (max) Built-in digital clock Daily test report Disarm/arm report 4 led keypads can be connected to control panel, 4-line connection Built-in digital communicator Attached digital communicator, compatible to contract idfa4+2 2 central station phone numbers 4 follow-me phone numbers
Lcd keypad (rp208kcl) Display of 32 characters in two lines 3 keypad emergency zones: panic[1]+[2], fire[4]+[5], special emergency[7]+[8] Menu indicates the user functions and the installer programing Key-press with audible feedback System condition display Trouble display Led indication: alarm, power, armed, disarmed, bypass, ready, tamper User information is displayed on screen (except password) Lcd backlight Tamper is supervised Alarm by duress code Easy to use hot-keys for simple bypassing and not-ready zones display One button for quick arming One button for quick perimeter arming Alarm memory display System trouble display Up to 4 lcd keypads can be connected Mainboardf]rp208mbf^ Zone terminal resistor (2.2kf±[) 8 zones of mainboard Expandable wired zone Special zones: zone-5 is fire zone, zone-6 is tamper zone 11 types of programmable zones, 7 types of voice formats Zone terminal: nc, no, single end with resistor Programmable output: 70ma Expandable to 4 large current output: 3a 50 event records 8 groups of 4 gradable codes Switch output: 250ma Built-in siren driver: 750ma max Built-in digital clock Daily test report Disarm/arm report 4 lcd keypads can be connected to control panel Circuit responding time of each zone can be set as 10ms, 500ms or 1s Mainboard has 7 types of fire alarm bell voice driver Connectible with four 1.5v 12a power supply expansion boards Mainboard has one 70ma programmable open circuit collector Connectible with 3a c-type programmble relay The distance is up to 1500m between module and control panel Siren voice output Siren voice type is programmble Current outputfg750ma(max) Auxiliary power output Auxiliary power output: 400ma Built-in digital communicator Attached digital communicator, compatible with contract idfa4+2 4 follow-me phone numbers 2 central station numbers Code One installing code One (user) main code (can create duress code automatically) 8 gradable user codes Periodic test Offer testing report to alarm center automatically Peripheral equipment With voice module Disarmed/armed by romote control. Any zone can be programmed to be the switch lock port Power supply output expansion module eps Connect with system by 4-line Provide 2.5a, 12v power to other modules and siren Complete supervision of power supply condition, including battery, ac, siren circuit and auxiliary power output Digital voice module rv2006v 1 piece of voice message, time lasts 20s Follow-me number is assignable Timing function Auto daily arm Auto daily test report Disarm/arm rreport at window Monitoring function Trouble data can be displayed on keypad, and also can be transmited to central station Spare battery in low power Expansion module of power supply battery in low power Siren circuit in trouble Phone line failure Loss of ac Loss of auxiliary power System clock is not set Line communication is blocked Tamper prevention Fire alarm circuit in trouble Installation All expansion modules can be connected to the system by 4-line The distance is up to 1500m between module and control panel Technical data Transformer 16.5vac 40va Spare battery 12v4ah Auxiliary power supply 350ma Switch lock 250ma Siren 750ma
Lcd keypads (rp248kcl) Display of two lines and 32 characters 3 keypad emergency zones: panic[1]+[2], fire[4]+[5], special emergency[7]+[8] Menu indicates the user functions and the installer programing Key-press with audible feedback System condition display Trouble display Led indication: alarm, power, armed, disarmed, bypass, ready, tamper User information is displayed on screen (except for password) Lcd backlight Tamper is supervised Alarm by duress code Easy to use hot-keys for simple bypassing and not-ready zones display One button for quick arming One button for quick perimeter arming Alarm memory display System trouble display Up to 4 lcd keypads can be connected Mainboardf]rp248mbf^ Zone terminal resistor (2.2k+[) 8 zones on mainboard Expandable up to 72 programmable zones Special zones: zone-5 is fire zone, zone-6 is tamper zone Can be parted to 8 divisions 11 types of programmable zones, 7 types of voice formats Zone terminal: nc, no, single end with resistor Programmable output: 70ma Expandable to 32 large current output: 3a 50 event records 8 groups of 4 gradable codes Switch output: 250ma Built-in siren driver: 750ma max Built-in digital clock Daily test report Function of end calling Disarm/arm report 4 lcd keypads can be connected to control panel Programmble voice for the siren output Current outputfg750ma(max) Auxiliary power output: 400ma Mainboard has 7 types of fire alarm bell voice drivers Connectible with four 1.5v 12a power supply expansion boards Mainboard has one 70ma programmable open circuit collector Connectible with 32 c-type programmble relays of 3a Circuit responding time of each zone can be set as 10ms, 500ms or 1s The distance is up to 1500m between module and control panel Built-in digital communicator Attached digital communicator, compatible with contract idfa4+2 2 central station numbers 4 follow-me phone numbers Code One installer code One (user) main code (can create duress code automatically) 8 gradable user codes Periodic test Offer testing report to alarm center automatically Peripheral equipment Expandable function of 32 lines relay output Disarmed/armed by romote control. Any zone can be programmed to be the switch lock port Rs232 port Expandable zone board 8 zones expansion module ez8 8 zones wiring expansion module Power supply output of switch lock Zones terminal: nc, no, single end with resistor (2.2k+[) Circuit responding time of each zone can be set as 10ms, 500ms or 1s 4-line connection, and easy for installation 8 zones wireless expansion module ew8 Wireless expansion module Time to supervise is programmable Monitoring of emitter in low power Tamper of emitter is supervised Indication of interfering signal Wireless detector is supported Verifying code by cycle 4 program output expansion module e04 4 lines programmable output(3a) Output: nc, no, locked or pulse Responding to various events Xto module supports x-10 agreement Power supply output expansion module (rp248eps) Connect with 5 modules by 4-line Provide 2.0a, 12v power to other module and siren Complete supervision of power supply condition, including battery, ac, siren circuit and auxiliary power output Built-in siren driver Tamper is supervised Memory when power is cut Digital voice module rv2006v 1 piece of voice message, time lasts 20s Follow-me number is assignable Timing function Auto daily arm Auto daily test report Disarm/arm report at window Monitoring function Trouble data can be displayed on keypad, and also can be transmited to central station Spare battery in low power Expansion module of power suplly battery in low power Siren circuit in trouble Power expansion module of siren circuit in trouble
Lcd keypads (rp248kcl) Display of two lines and 32 characters 3 keypad emergency zones: panic[1]+[2], fire[4]+[5], special emergency[7]+[8] Menu indicates the user functions and the installer programing Key-press with audible feedback System condition display Trouble display Led indication: alarm, power, armed, disarmed, bypass, ready, tamper User information is displayed on screen (except for password) Lcd backlight Tamper is supervised Alarm by duress code Easy to use hot-keys for simple bypassing and not-ready zones display One button for quick arming One button for quick perimeter arming Alarm memory display System trouble display Up to 4 lcd keypads can be connected Mainboard¡]rp248mb¡^ Zone terminal resistor (2.2k£[) 8 zones on mainboard Expandable up to 72 programmable zones Special zones: zone-5 is fire zone, zone-6 is tamper zone Can be parted to 8 divisions 11 types of programmable zones, 7 types of voice formats Zone terminal: nc, no, single end with resistor Programmable output: 70ma Expandable to 32 large current output: 3a 50 event records 8 groups of 4 gradable codes Switch output: 250ma Built-in siren driver: 750ma max Built-in digital clock Daily test report Function of end calling Disarm/arm report 4 lcd keypads can be connected to control panel Programmble voice for the siren output Current output¡g750ma(max) Auxiliary power output: 400ma Mainboard has 7 types of fire alarm bell voice drivers Connectible with four 1.5v 12a power supply expansion boards Mainboard has one 70ma programmable open circuit collector Connectible with 32 c-type programmble relays of 3a Circuit responding time of each zone can be set as 10ms, 500ms or 1s The distance is up to 1500m between module and control panel Built-in digital communicator Attached digital communicator, compatible with contract id¡a4+2 2 central station numbers 4 follow-me phone numbers