"Product name
Fire Extinguisher Cylinder
Type
0.5kg/0.8kg/1.2kg/1.3kg/1.35kg/Cutomized
Material
Steel
Usage
CO2 Fire Fighring
Keywords
Co2 Fire Extinguisher
Color
Customer Request
Working pressure
150bar"
Our fire extinguishers are designed for maximum safety and efficiency, suitable for homes, offices, and industrial use. Available in various types and capacities, they provide reliable fire protection for different hazards.
The FK-5-1-12 Clean Agents, also known as NOVEC1230 Fire Suppression Agents, is a highly efficient and reliable hydro-fluorocarbon fire extinguishing solution. This product is designed to quickly and effectively suppress fires in various settings while being non-toxic, environmentally friendly, and safe to use.
Model Number: FK-5-1-12 clean agents
Product Name: NOVEC1230 Fire Suppression Agents
Reliability: High
Model NO.: FK-5-1-12 clean agents
Application
The FK-5-1-12 Clean Agents is suitable for use in various applications, including but not limited to:
Commercial buildings
Industrial facilities
Data centers
Telecommunication rooms
Museums and art galleries
Power generation plants
Server rooms
Control rooms
Storage facilities
The Notifier NBG-12 Series Pull Station is a fire alarm initiation device that allows manual activation of the fire alarm system. It typically consists of a red or yellow manual-pull handle or lever, which when activated, sends a signal to the fire alarm control panel to initiate an alarm. The NBG-12 series is designed for use in fire alarm systems and is commonly used in commercial, industrial, and residential buildings. The product is known for its durability and reliability, and it meets industry standards for fire alarm systems.
Intelligent fire Detection system as a high efficiency and low cost unmanned fire detection system in capable of an early detection regardless spontaneously fire or firebug.
This system is located in outdoor area such small and middle sized cultureal assets, natural monument and outdoor facilities.
A fire alarm system is a set of electric/electronic devices/equipment working together to detect and alert people through visual and audio appliances when smoke/fire is present. These alarms may be activated from smoke detectors, heat detectors, water flow sensors, which are automatic or from a manual fire alarm pull station.
Types of Fire Alarm System:
All Fire Alarm Systems essentially operate on the same principle. If a detector detects smoke or heat or someone operates a break glass unit (manual break point), then alarm sounders operate to warn others in the building that there may be a fire and to evacuate. It may also incorporate remote signaling equipment which would alert the fire brigade via a central station.
Conventional Fire Alarm System
In a Conventional Fire Alarm System, a number of call points and detectors are wired to the Fire Alarm Control Panel in Zones. A Zone is a circuit and typically one would wire a circuit per floor or fire compartment. The Fire Alarm Control Panel has a number of Zone Lamps. The reason for having Zones is to give a rough idea as to where a fire has occurred. This is important for the fire brigade and of course for the building management. The accuracy of knowing where a fire has started is controlled by the number of Zones a Control Panel has and the number of circuits that have been wired within the building. The Control Panel is wired to a minimum of two sounder circuits which could contain bells, electronic sounders or other audible devices. Each circuit has an end of line device which is used for monitoring purposes.
Addressable Fire Alarm System
The detection principle of an Addressable System (Fire Alarm System) is similar to a Conventional System except that the Control Panel can determine exactly which detector or call point has initiated the alarm. The detection circuit is wired as a loop and multi devices may be connected to each loop. The detectors are essentially Conventional Detectors, with an address built in. The address in each detector is set by dil switches and the Control Panel is programmed to display the information required when that particular detector is operated. Additional Field Devices are available which may be wired to the loop for detection only i.e. it is possible to detect a normally open contact closing such as sprinkler flow switch, or a normally closed contact opening.
Fire Alarm System comes with single loop as well as multi loops. It depends on requirement. The items which are integrated with Fire Alarm Systems are given belowâ?¦.
Brands are available : AGNI, MORLEY, NOTIFIER,
Modern Technologies gives you top class branded Fire Alarm System with affordable price. We also provide installation & maintenance services.
Fire extinguisher, portable or movable apparatus used to put out a small fire by directing onto it a substance that cools the burning material, deprives the flame of oxygen, or interferes with the chemical reactions occurring in the flame. .
1kg dry powder fire extinguisher – ce tuv approved
An easy to use fire extinguisher by streetwise for all areas where there could be a potential fire including in the home, in the garage, in the workplace, in the caravan, on boats, in schools, cars, vans and taxis
As this is such a portable item you’ll be able to place it anywhere stated in the places above. Just pull out the pin while holding the extinguisher upright and your ready to aim and shoot
The unit comes complete with a quick release wall cage that can be bolted on to a convenient surface for easy access and fast deployment.
Fire types this powder extinguisher will put out:
Class a: fires involving common combustibles like wood, paper, cloth and upholstery.
Class b: flammable liquid.
Class c: flammable gas fires.
Specifications
• ce and tuv approved
• weight: 1kg (dry chemical powder)
• operating temperature range: -30°c - + 60°c
• height: 300mm
• diameter: 270mm
• free mounting bracket included