JW-032A Power Supply: 220V 50Hz / 220V 60Hz / 110V 60Hz Power : 1.5HP Air Flux: 124L/min(0.4Mpa) Noise:68dB Max Pressure:0.75Mpa Start-up Pressure 0.5Mpa Rev. :1400r/min Capacity:55L
JW 031C Power Supply:220V 50HZ /220V 60HZ/110V 60HZ Power : 0.7HP Air Flux: 62L/min(0.4Mpa) Noise:58dB Max Pressure:0.75Mpa Start-up Pressure 0.5Mpa Rev. :1400r/min Capacity:30L
JW-032B Power Supply: 220V 50Hz / 220V 60Hz / 110V 60Hz Power : 1.1HP Air Flux: 100L/min(0.4Mpa) Noise:65dB Max Pressure:0.75Mpa Start-up Pressure 0.5Mpa Rev. :1400r/min Capacity:40L
JW-032A Power Supply: 220V 50Hz / 220V 60Hz / 110V 60Hz Power : 1.5HP Air Flux: 124L/min(0.4Mpa) Noise:68dB Max Pressure:0.75Mpa Start-up Pressure 0.5Mpa Rev. :1400r/min Capacity:55L
**Ready stock in Turkey** -Price: USD11,000/CIF by air *without compressor -Price: USD12,000/CIF by air *with compressor -Operation Features- Inspiration Pressure: 2-100 mBar Inspiration Duration: 0.1-10 Sec. Peep Pressure: 0-50 mBar Breathe Speed: (c) 1-150/mins. (y) 1-100/mins. Flow: (c) 1-60 lt/mins. (y) 2-120 lt/mins. O2 Mixture: 21-100% Spontaneous Pressure Support: 0-100 mBar I/E Rate: 1:10 (x60*)-10:1 (c): Child, (y): Adult
Here are some general features that you might find in KARL STORZ laparoscopes: Diameter: Laparoscopes come in different diameters, and the choice depends on the specific surgical procedure and patient anatomy. Common diameters include 5mm and 10mm. Angle of View: The angle of view is an important parameter. For instance, a laparoscope with a 30-degree angle provides a wide field of view, while a 0-degree laparoscope offers a straight-ahead view. Autoclavable: Many laparoscopes are designed to be autoclaved, allowing for sterilization and reuse. Optics: High-quality optics are crucial for clear visualization during surgery. KARL STORZ laparoscopes typically feature advanced optics for improved image quality. Light Transmission: Efficient light transmission is essential for illuminating the surgical field. LED or xenon light sources are often used for this purpose.
Here are some general features that you might find in KARL STORZ laparoscopes: Diameter: Laparoscopes come in different diameters, and the choice depends on the specific surgical procedure and patient anatomy. Common diameters include 5mm and 10mm. Angle of View: The angle of view is an important parameter. For instance, a laparoscope with a 30-degree angle provides a wide field of view, while a 0-degree laparoscope offers a straight-ahead view. Autoclavable: Many laparoscopes are designed to be autoclaved, allowing for sterilization and reuse. Optics: High-quality optics are crucial for clear visualization during surgery. KARL STORZ laparoscopes typically feature advanced optics for improved image quality. Light Transmission: Efficient light transmission is essential for illuminating the surgical field. LED or xenon light sources are often used for this purpose.
Elbow Joint Splint (AJY-S12) It is used for elbow joint fixation for tendon, soft tissue, and nerve injury in the elbow joint in time for postoperative fixation of the joint. 448*260*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy
Achilles tendon dorsal splint (AJY-S11) It is used for dorsal fixation after Achilles tendon injury, topological fixation of supporting foot. 442*247*3.2mm LOW TEMPERATURE THERMOPLASTIC SHEET Product features: Low temperature thermoplastic sheet is a new type of material made of specially synthesized polymer polycaprolactone treated by a series of chemical methods. Molecules are in a stable state at room temperature (10-30C), and can be softened after being heated in 65-70C water for 1-3 minutes. Curing in 3-5 minutes at room temperature. It has the advantages of light weight, high strength, good air permeability, not afraid of water, non-toxic, odorless, non-irritating to the skin, etc., and has biodegradability. Scope of application: 1. Fixation after reduction of fractures and joint dislocations 2. Postoperative fixation of soft tissue injuries such as joint ligaments, nerve and tendon injuries 3. Bone, joint tuberculosis, acute and chronic osteomyelitis, septic arthritis, primary bone Fixation during conservative treatment such as tumor metastasis or after debridement 4. Joint deformity, nerve palsy, cerebral palsy, scoliosis correction and postoperative fixation in children and fixed 5. Fixation after burns and other plastic surgery operations 6. Production and application of rehabilitation braces and orthoses 7. Posture placement and fixation during radiotherapy