Supplier: Car battery and home UPS, inverter battery
Services: Export and service
Supplier: Luminous home ups, inverter batteries, and solar products, amc of batteries
Services: Distributors
Product Description We produce VRLA/SLA Battery, lead battery, Industrial Battery, 12V/ 6V Battery, Rechargeable Battery, Gel Battery, Deep Cycle Battery, sealed lead acid battery and so on. 12v 7ah backup battery (20hr battery) Valve regulated lead acid series UPS batteries are designed with AGM (Absorbent Glass Mat) technology, high performance plates and electrolyte to gain extra power output for common power backup system applications widely used in the field of UPS, Emergency Lighting System. Battery Structure 1. Container/Cover: Made of UL94HB and LU 94V-0 ABS Plastic 2. Negative Plates: Use the special PbCa alloy grids, optimize the recombination efficiency and less gassing. 3. Separator: Import high quality AGM separator. 4. Postive Plates: PbCa grids minimize corrosion and prolong life. 5. Terminal post: Cooper material with maximum conductivity, enhance the high current rapidly. 6. Vent Valve: Allows the release of excess gas automatically for safety. Power Supply 12V 7ah UPS Backup Battery (20hr battery)
Fuji Electric's UPS and power solutions have the best product specifications with the latest technology. Fuji's products are available in the 72 VA to 2000 kVA range, for single modules. For higher ratings, these can be paralleled to deliver 12000 kVA. Fuji Electric's high efficiency UPS helps in reducing costs, weight, footprint and heat.
01. Nominal power Capacity: Volts-Amps/Watts(VA/W): 1000VA/700W 2000VA/1400W 3000VA/2100W . 02. Input Nominal Voltage: 110/115/120Vac or 220/230/240Vac Voltage Range:60-138VAC or 115-300VAC Frequency Range:50Hz: 46-54Hz(Default), 60Hz:56-460Hz Power Factor: í¦0.95 í¦0.97 . 03. Output Voltage: 110/115/120Vac or 220/230/240Vac Frequency Synchronized: 46-54Hz or 50Hzí+ 0.2Hz(Line mode)50Hzí+ 0.2Hz(Battery mode) Wave-form: Sine Wave Distortion: í_3% (Full linear load) í_4% (Full linear load) Overload Capability: 108%-150% for 30sec: í¦150% for 200ms Crest Ratio 3: 01 . 04. Battery Type: Sealed Lead-Acid, Maintenance free Capacity: 12V/7AH*3pcs 12V/7AH*8pcs Back-up time: (Full /half load) 5mins/14mins 9mins/21mins 5mins/17.5mins Recharge time: 5hours to 90% of full capacity after full load discharge . 05. Transfer time: 0ms; 2.5ms typical from inverter to bypass and vice versa . 06. LED indicators Status Battery level, Battery mode, Line mode, Inverter, Bypass, Overload, fault. 07. Audible Alarm: Battery mode: Alarm beeps every four seconds, every second if battery low Overload: Alarm beeps two for every second Fault: Alarm beeps continuously. 08. Acoustic Noise: At 1 meter distance 45dBA 50dBA. 09. Communications DB-9 Connector: RS232 Serial interface; Power monitoring and unattended systems shutdown via kavass2002 Intelligent Slot SNMP: Power management from SNMP manager . 10. Network Surge Protection: RJ45 I/O port available for 10base -T network or Fax/Modem . 11. Environment Operating Temperature: 0-40 Operating Humidity: 20-95% non-condensing . 12. Applications Servers Data-center, Critical network, Sensitive electronic equipment, Telecom. 1KVA500*240*335mm 2KVA3KVA 590*335*480mm Cartons, foam and wooden.
1. Nominal Power Capacity: Volt-Amps/Watts(VA/W) 6000VA/4200W 10000VA/7000W . 2. Input Nominal Voltage (Single): 220Vac Voltage Range: 176-300Vac Frequency Range: 46.5-55Hz Power Factor: í¦0.95 í¦0.97. 3. Output Voltage Range: 220Ví+ 2% Frequency Synchronized: 46.5-55Hz or 50Hzí+ 0.2Hz(Line mode)50Hz0.2Hz(Battery mode) Wave-form: Sinewave Distortion: í_3%(full linear load) í_4%(full linear load) Overload Capability: 108%-150% inverter mode for 10 minutes í¦130% by pass mode for 1 minute. 4. Crest Ratio: 3: 01 5. Battery Type: Sealecd Lead -Acid, Maintenance Free Capacity: 12V/7AH*20PCS 12V/7AH*40PCS 6. Transfer time: 0ms; 2.5ms typical from inverter to bypass and vice versa 7. Battery mode: Alarm beeps every four seconds, every second if battery low Overload: Alarm beeps two for every second Fault: Alarm beeps continuously 8. Acoustic Noise: At 1 meter distance 45dBA 50dBA 9. Communications: DB-9 Connector RS232 Serial Interface; Power monitoring and unattended systems shutdown via software 10. Applications: Servers Data-Center, Critical network, Sensitive electronics equipment, Telecom. 705*435*950mm Foams,cartons and Palet.
Supplier: UPS, interactive UPS & offline UPS, home UPS, power inverter, lead-acid battery, UPS batteries