Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
Supplier: Quartz powder, quartz lumps, wire nails, threaded rods, crc coils, aluminium sheets, saip chq wires
Services: Clearing agent, shipping
We Can Supply Freestyle Libre 2 Flash Glucose Monitoring System Sensor Please Dont Hesitate to Contact Us in Case of Any Interested
Application :- These single core flexible cables are used for wiring in control panels, machines and various electrical installations In small, medium and large industries. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables have low conductor resistance. These wires are insulated with a special grade PVC compound formulated and manufactured in-house which is impervious to water, oil, grease, acids, etc. and are tough to protect from any mechanical abuses. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.50 to 50.00 Sq. mm with ISI mark & 70.0 to 40.0 Sq. mm generally conforming to IS:694 Color Codes : Red, Yellow, Blue, Black, Grey, White, Pink, Green, Violet, Brown, Orange Specification : IS:694 Packing : In 90 meter coils, higher sizes in drums.
Application :- These multi core flexible cables are used for wiring in control panels, machines and various electrical installations in dry and damp interiors specially under typical industrial environmental conditions. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables offer low conductor resistance. These wires are insulated with a special grade PVC compound formulated and manufactured in-house. The tough robust outer PVC jacket protects it from oils, greases and various chemicals and abrasions, thereby giving long life and electrical safety. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.50 to 4.00 Sq. mm in 2 core to 19 cores & 6.00 to 120.00 Sq. mm in 3 core and 4 core. Color Codes : Black and Grey Outer Sheath 2 Core Cables - Red, Black 3 Core Cables - Red, Black & Green (for Earth) 4 Core Cables - Red, Yellow, Blue & Green (for Earth) 5 Core Cables - Red, Yellow, Blue, Black & Grey Specification : IS:694 Packing : In 90 meter coils, higher sizes in drums.
Application :- This is a premium product of electrical wires from \'JPCL\'. These cables are ideal for wiring in residential and commercial complexes, high-rise buildings, hotels, hospitals, schools, colleges, etc. (where the density of people is high). During a fire, these cables not only emit less smoke and toxic hydrochloric acid gas but also retard the spread of fire enabling those trapped inside to escape safely. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables have low conductor resistance resulting in power saving. These wires are insulated with a special grade PVC compound formulated and manufactured in-house only. The insulation is far superior in terms of critical oxygen and temperature index as well as in light transmission and acid gas generation. The skin coloration offers high insulation resistance and long life. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.75, 1.00, 1.50, 2.50, 4.00 and 6.00 Sq. mm Color Codes : Red, Yellow, Blue, Black and Green (For Earthing) Specification : IS:694 Packing : In 90 meter coils in attractive cartons
Photocells Fans & ventilation, Hazardous area lighting Industrial plugs & sockets Industrial & commercial Lamps Light fittings: fluorescent, weatherproof & floodlighting Refrigeration & air conditioning spares Water heating elements Wiring accessories MCB's Circuit breaker Vacuum Breakers Control transformers Fuses & load break devices Hazardous area products Industrial beacons Industrial sounders, buzzers Industrial surge protection Safety switches Clamp meters Multi-meters Testers Semiconductors: thyristors, rectifiers Pressure switches Solenoid & pilot valves Photoelectric Sensors
Product Overview The ignition point of a fire inside the electric panel is mostly the part where the terminal block is fastened, so in order for initial fire extinguishing, the solution should be closely installed to the part where the terminal block is fastened. In the case of a small electric panel, a complete initial fire extinguishing is expected for fires occurring inside the electric panel by attaching the SFEX Pad to the top surface of the electric panel. Product Feature It has an excellent performance in the initial fire suppression as it can be installed near the ignition point as a flexible rope type. It uses a stand-alone method based on polymer chemistry so that it does not cause malfunctions and maintenance costs. The thermo-responsive Granule composed of KNO3 and subsidiary catalysts It does not affect the peripherals after the fire goes out. Function of SFEX Granule = fire extinguishing agent storage tank + temperature sensor + nozzle function Fire extinguishing method : Suffocation + subsidiary catalyst Example of Installation 1 : SFEX Line - If ducts exist Installing the SFEX Line horizontally or vertically in the ducts closest to the expected ignition points It can be installed without damaging the panel Example of Installation 2 : SFEX Line - If ducts do not exist Installing the SFEX Line horizontally or vertically, close to the expected ignition points of the Electric panel Example of Installation 2 : SFEX Pad - Small Electric Panel Simply attach it to the top inside the Electric panel.
L high reliability, low drift Applications L automotive pressure monitoring L pneumatic gages L hand-held meters