Basic Info. Model NO. PST120-12 Installation Packaged Rechargeable Chargeable Color Ivory White Weight 34.5kg Terminal Cooper Case ABS Separator AGM Plate Flat Plate Maintenance Free Sealed Type Glue Sealing Transport Package Carton Then Pallet Specification 407*174*209mm Trademark PUSTUN Origin China HS Code 8507200000 Production Capacity 600PCS/Day Product Description We produce VRLA/SLA Battery, Industrial Battery, 12V Battery, Rechargeable Battery, Gel Battery, Deep Cycle Battery, sealed lead acid battery and so on. GEL Battery for UPS/EPS, Power wheels, Inverters, Off grid solar system, Solar street light, Telecommunication and other electrical D/C power sources. Deep cycle & High performance. Professional 12V120Ah Gel Battery
Basic Info. Model NO. PTD250-12 Installation Packaged Rechargeable Chargeable Weight (Kg) 68kg Color Black/Ivory White Terminal Type Lead / Bolt & Nut Safety Explosion-Proof Battery Case ABS Separator AGM Sealed Type Sealed Transport Package Carton / Wooden Case / Pallet Specification 520x268x243 mm Trademark PUSTUN Origin Guangzhou, China HS Code 8507200000 Production Capacity 600PCS/Day Product Description We produce VRLA/SLA Battery, Industrial Battery, 2V/6V/12V Batteries, Rechargeable Battery, Gel Battery, Deep Cycle Battery, sealed lead acid battery and so on. Valve regulated lead acid deep cycle series batteries are designed with AGM (Absorbent Glass Mat) technology, high performance plates and electrolyte to gain extra power output for common power backup system applications. Advanced Features: 1. Environmentally friendly 2. Completely Maintenance-Free 3. Non-Spillable construction design. 4. Wide Operating Temperature Range(-20�°C~+60�°C) 5. Long Life (12-15 years designed life) 6. Explosion Proof 7. Valve Regulated & High Discharge Rate Capability 8. Low Self Discharge 9. Independent of Position 10. Ease of Shipment 11. No need of balanced charge or boost
Product Description gel accumulator 2v 800ah (OPzV800-2) OPZV800-2 Opzv Series Valve Regulated Lead Acid batteries are designed with a proven combination of GEL and Tubular technologies to offer a very high level of reliability. Opzv batteries benefit from an optimized plate design which gives capacities in excess of the DIN standard values. In addition, this series offers both a longest float life and a high cycle life in widely industrial field. Safety and Sealed No electrolyte leakage will occur from terminals or case or case of any Storace Battery ensuring safe and efficient operation. Maintenance-Free operation There is no need to add water thanks to unique gas recombination system which totally transforms the generated gas into water. Storace batteries do not need the equalizing charge As a result of monomer battery's interface resistance capacity and float voltage uniformity are fine. No Free Acid The special electrolyte retentive separators bold the acid and thus there is no free acid inside the battery, and therefore the battery can be mounted in any position. Long life Design The use of heavy -duty lead-calcium alloy grids with anti-corrosive construction enables the Storace AGM battery to remain in float service for 10-15 years; the GEL battery to remain in float service for 15-20 years. The cycle life can be more than 1000 cycles High Reliability and stable quality With advancing AGM and GEL production technology and strictly quality control system, the battery quality is stable and the battery performance is reliable. The voltage, capacity and seal are 100% tested on line. Self-discharge The self-discharge rate in room temperature is approximately 2% of nominal Capacity per month. Operating temperature TheStorace Battery can be operated between -40�°C to +65�°C.The battery can give out over40% fo nominal capacity at -40�°C.
Basic Info. Model NO. PST12-12 Installation Packaged Rechargeable Chargeable Size 151*98*94mm Weight 3.43kg Color Black / Dark Gray Cell 3 Sealing Glue Sealing Separator AGM Flat Plate Plate Battery Case ABS Terminal Lead Safety Explosion-Proof Transport Package Carton, Then Pallet Specification CE/ FCC Trademark Pustun Origin China HS Code 8507200000 Production Capacity 2000 PCS/Day Product Description Maintenance Free Sealed Lead Acid Storage Battery, Deep Cycle AGM Type VRLA Battery for UPS, Solar Power System, Wind Renewable Energy, PV Application, Emergency Lighting, CCTV, Street Light, Fire & Security Alarm, Medical Equipment and so on.
Basic Info. Model NO. PST200-12 Installation Packaged Rechargeable Chargeable Size 522*239*2180mm Weight 60kg Color Black / Dark Gray Cell 3 Sealing Glue Sealing Separator AGM Flat Plate Plate Battery Case ABS Terminal Lead Safety Explosion-Proof Transport Package Carton, Then Pallet Specification CE/ FCC Trademark Pustun Origin China HS Code 8507200000 Production Capacity 2000 PCS/Day Product Description Maintenance Free Sealed Lead Acid Storage Battery, Deep Cycle AGM Type VRLA Battery for UPS, Solar Power System, Wind Renewable Energy, PV Application, Emergency Lighting, CCTV, Street Light, Fire & Security Alarm, Medical Equipment and so on.
Basic Info. Model NO. LFP51.2-300 Electrolyte LiFePO4 Color White Usage Solar/ Marine/ Telecom / Electric Mobility Warranty 3 Years OEM/ODM Acceptable Package Carton and Pallet Lead Time 20-30 Days Dimension 720*260*580mm Transport Package Wooden Case Specification 120kg Trademark PUSTUN Origin China HS Code 8507600090 Production Capacity 5000 Product Description Product Description Factory Wholesale Deep Cycle 51.2V300ah Lithium Ion Batteries LiFePO4 Lithium iron phosphate battery is a kind of lithium ion battery that uses lithium iron phosphate (LiFePO4) as the positive electrode material and carbon as the negative electrode material. It has the advantages of high working voltage, high energy density, long cycle life, good safety performance, low self-discharge rate and no memory effect. Pustun lithium iron phosphate battery is your best power choice for energy storage system of solar street light. This LFP series battery is specifically designed for solar street light application, which has more than 10 years service life; LFP series batteries are the best choice for the durable, safe, environment-friendly energy solution and they can be customized according to your requirement, such as dimension, voltage, capacity of battery. With an increased lifespan, this battery can save you much cost against frequent battery replacement. The working life of lithium battery especially under the outdoor high temperature environment is five times longer than the traditional lead acid battery. Product Parameters Nominal Voltage 51.2V Nominal Capacity 300Ah Energy 15.36KWh Combination mode 16S1P Cycle Life â?¥6000 Cycle, 80%DOD, 25�ºC BMS conï¬?guration 16S150A Operating voltage range 41.6V~59.2V Rated charge and discharge current 150A Peak current 160A Continue @170A 3s Rated charging and discharging power 7.68Kw Peak power 8.192Kw Continue @8.704Kw 3s Short-circuit current 0.762Ka@100us Communication mode CAN, RS485 Parallel number Recommend 6 in parallel(Maximum support 16 in parallel) Remote data Bluetooth optional/Wiï¬? Weight 120kg Dimensions (L*W*H) mm 720*260*580mm Operating temperature Charging: 0�ºC~+50�ºC / Discharge: -10�ºC~+60�ºC Relative humidity 0~95% Storage temperature
Model: 2V200AH, 300AH, 420AH------3000AH Material with material of virgin material or changed material Have a long life span The colour is black or white We are an expert in design and manufacturing all kinds Of high accuracy plastic mould, especially specialized in battery Container jar, lids cover moulds. Now we have complete set of 2V and 12V battery box(OPZS, OPZV)from 200AH to 3000AH and are developping More items.
Battery Type: Lithium Iron Phosphate Battery Nominal Voltage: 12.8V Nominal Capacity: 50.0Ah Battery Brand: VCELL/OEM Model: VP-LF12-50 Charge Cut-Off Voltage: 14.6 ±0.2V Discharge Cut-Off Voltage: 10.0 ±0.2V Max charge current: 50.0A Max continuous discharge current: 50.0A Peak discharge current: 100.0A(1-3S) Charge temperature: 0~45 Discharge temperature: -20~65 Storage Temperature: -20~50 Design Life: 10 Years Size(L*W*H): 229*138*212*217mm Weight: 5.7KgApprox Cycle life: 4000 @100% DOD 1C Charge/Discharge Terminal: M6 IP Level: IP55
Basic Parameters Dimensions: 201 x 99 x 35 mm Weight: 333g Adapter Input: AC 100 ~ 240 V Output: DC 24V 2.65A Display mode Segment LCD with white backlight + LED in red and green Function Introduction Charge Active, pre-charge, constant current and constant voltages are the stages of charging mode. The initial charging mode depends on the battery voltage, so active and pre-charge don't happen to every batteries. For charging mode and current, please refer to the paragraphs of charging mode and charging current on page 2 & 3. Tester will stop charging if one of the conditions below was met. 1) Remaining capacity 99% & current intensity = 0 2) Remaining capacity = full charge capacity 3) Current intensity reduce to end charge current when constant voltage charge 4) Remaining capacity reach up the set value Discharge Constant current discharge for double loads Inner load: 0 ~ 1000mA, adjustable continuously via Battery Manager External load: 0mA, 500mA, 1000mA, 1500mA, 2000mA, five gears with dip switches offered Tester will stop discharging if one of the conditions below is met. 1) Remaining capacity set value 2) Voltage set value 3) Current intensity reduce to zero Remarks: Many batteries can not measure exact current intensity, which cause an else current value appears after you set a value. However, the actual discharging current is the same with your set value. Test Testing time is 12 seconds and the purpose is to check both the charging and discharging performances. After finishing test, LED flickers with green color and LCD reports the test result. Normal: Test OK Shown on LCD Abnormal: Test NG Shown on LCD Possible causes and solutions for the abnormal: 1) Cause: battery voltage is too low to discharge Solution: try to charge the battery to raise voltage 2) Cause: remaining capacity is too full to charge any more Solution: try to discharge the battery to reduce the remaining capacity 3) Bad contact of battery connecting wires 4) Damaged battery 5) Tester trouble Capacity Correction The battery capacity value in the battery management chip will different from the actual capacity after a battery goes through many recycling cycles. It will affect the use of the battery when the difference reaches a certain degree. Capacity correction is to deep discharge a battery and then fully charge, which will correct the capacity value in the battery management chip. Remarks: Discharging current can be set via Battery Manager. Deep discharge will cause a battery losing communication with tester, so battery dropping phenomenon may happen in the discharging process if the end capacity and voltage are set too low. In such a case, active charge will make the battery work again. 50% Capacity CD50%: charge firstly, and then discharge to 50% capacity DC50%: discharge firstly, and then charge to 50% capacity Online Functions Tester can be connected with master machine via a USB port. Users can monitor, control and set parameters via Battery Manager software in the master machine. Monitoring Battery information can be monitored via three windows. 1. Home screen Battery bar and brief information can be read on home screen. 2. Battery detail information window Show smart battery data in real time and the data can be saved and printed in image format. 3. Battery graph window Voltage, current and capacity are traced in curves. Control Battery Manager can control slave machine completely. Right-click menu on the battery bar includes the related commands. Attention All the functions of charge, discharge, capacity correction and 50% capacity are comply with the charging discharging conditions, which are showed on function introduction paragraph in page 4 & 5, so parameters should be set reasonably. Especially, deep discharge will cause a battery losing communication with tester. Others 1. Active cooling 2. Active batteries of zero voltage When a battery is deep discharged, the discharge protection circuit will start up and the voltage in the battery connector will become zero voltage. In this case, an appropriate voltage should be supplied to active the battery. 3. Battery identification Battery information can be read from battery management chip after establishing communication. 4. Intelligent protection Against over-current, over-voltage, over-charge, over-heat and short circuit. 5. Fan Discharging mode: fan startup Other modes: fan startup when temperature above 48 Fan stop working when temperature below 40 6. Trouble alarm LED flickers in red color and current command stops when one of the conditions below happen. 1). There is not current for around 50 seconds when charge. 2). There is not current for around 25 seconds when discharge. 3). Charging time is above 8.8 hours. 4). Discharging time is above 9.9 hours. 5). Suitable for almost all laptop batteries, above 95% Structure Accessories 1).1 * adapter 2). 1 * USB cord 3). 1 * CD 4). 13 * connectors 5). 10 * cables 6). 10 * jumpers 7). 1 * loader Standard Export Carton