Supplier: Japanese quality switchgear components, breakers, magnetic contactors, switches, pilot lights, pushbuttons, panel instrumentations, power management meter, protection relays, transformers, inverters, ups.
AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply Product Introductionï¼? SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger. Unique function High efficiency over the full load range, full load efficiency greater than 95% Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main featuresï¼? Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs. Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. RS485 interface (Optional)
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Photocells Fans & ventilation, Hazardous area lighting Industrial plugs & sockets Industrial & commercial Lamps Light fittings: fluorescent, weatherproof & floodlighting Refrigeration & air conditioning spares Water heating elements Wiring accessories MCB's Circuit breaker Vacuum Breakers Control transformers Fuses & load break devices Hazardous area products Industrial beacons Industrial sounders, buzzers Industrial surge protection Safety switches Clamp meters Multi-meters Testers Semiconductors: thyristors, rectifiers Pressure switches Solenoid & pilot valves Photoelectric Sensors
Application :- This is a premium product of electrical wires from \'JPCL\'. These cables are ideal for wiring in residential and commercial complexes, high-rise buildings, hotels, hospitals, schools, colleges, etc. (where the density of people is high). During a fire, these cables not only emit less smoke and toxic hydrochloric acid gas but also retard the spread of fire enabling those trapped inside to escape safely. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables have low conductor resistance resulting in power saving. These wires are insulated with a special grade PVC compound formulated and manufactured in-house only. The insulation is far superior in terms of critical oxygen and temperature index as well as in light transmission and acid gas generation. The skin coloration offers high insulation resistance and long life. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.75, 1.00, 1.50, 2.50, 4.00 and 6.00 Sq. mm Color Codes : Red, Yellow, Blue, Black and Green (For Earthing) Specification : IS:694 Packing : In 90 meter coils in attractive cartons
Application :- These single core flexible cables are used for wiring in control panels, machines and various electrical installations In small, medium and large industries. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables have low conductor resistance. These wires are insulated with a special grade PVC compound formulated and manufactured in-house which is impervious to water, oil, grease, acids, etc. and are tough to protect from any mechanical abuses. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.50 to 50.00 Sq. mm with ISI mark & 70.0 to 40.0 Sq. mm generally conforming to IS:694 Color Codes : Red, Yellow, Blue, Black, Grey, White, Pink, Green, Violet, Brown, Orange Specification : IS:694 Packing : In 90 meter coils, higher sizes in drums.
Application :- These multi core flexible cables are used for wiring in control panels, machines and various electrical installations in dry and damp interiors specially under typical industrial environmental conditions. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables offer low conductor resistance. These wires are insulated with a special grade PVC compound formulated and manufactured in-house. The tough robust outer PVC jacket protects it from oils, greases and various chemicals and abrasions, thereby giving long life and electrical safety. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.50 to 4.00 Sq. mm in 2 core to 19 cores & 6.00 to 120.00 Sq. mm in 3 core and 4 core. Color Codes : Black and Grey Outer Sheath 2 Core Cables - Red, Black 3 Core Cables - Red, Black & Green (for Earth) 4 Core Cables - Red, Yellow, Blue & Green (for Earth) 5 Core Cables - Red, Yellow, Blue, Black & Grey Specification : IS:694 Packing : In 90 meter coils, higher sizes in drums.
Application :- The Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with PVC compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The inner & outer sheaths can be PVC, HR PVC, FRLS, HR-FRLS or FR depending upon the application and requirement. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C or +85�°C in HR PVC Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 & 4 core. Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:1554 (Part-1) Packing : 500 / 1000 meters on drums
Application :- The XLPE (Cross Link Poly Ethylene) Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with XLPE compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The outer sheaths can be PVC, HR PVC, FRLS or FR depending upon the application and requirement. Technical Advantage of XLPE Insulation :- Higher current rating, higher short circuit rating (approx 1.2 times that of PVC), thermosetting in nature, higher insulation resistance (1000 times more than PVC cables), higher moisture resistance, better resistance to surge currents, low dielectric losses, better resistance to chemicals and corrosion, longer service life. Comparatively higher cable operating temperature 90�°C and short circuit temperature 250�°C. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +90�°C Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:7098 (Part-1) Packing : 500 / 1000 meters on drums