Transformers,Distribution and Power Transformer,Varivolt
Safety Transformers
Diesel Generators
Industrial Panels
Stabilizers
Energy Saver
Industrial Panels
Transformer Manufacturers in and , Suppliers and exporters. Our offered Transformers are designed for keeping different customers and their requirements in mind, we use only superior quality raw material while the transformers which make us trusted Transformer Manufacturers in . Being a leading Transformer Manufacturers In we have a wide scope of our items including Control Transformer, Step-down Transformer, etc.
Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard
technical parameter
1. Temperature:
2. Relative humidity
3. Rated Primary Current:5-5000A 5A,1A
4.Rated secondary current:5 1A
5 Accuracy Class 0.05S
6. Allow long-term work under the rated current; More than120A across the core.
Precautions:
1. The current of standard CT and tested CT must be the same in CT calibration.
2. Follow the given wiring diagram strictly.
3. Test whether the load box is accurate or not before calibrating the transformer.
4. Forbid secondary winding opening during the calibration.
5. Select demagnetization before calibration.The wiring diagram is shown in figure 5.
Short out the secondary winding before cutting off the power when the demagnetization is finished.
6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard
technical parameter
Temperature -5 40
Relative humidity 80%
Rated Primary Current 5-5000A 5A,1A
Rated secondary current 5A 1A
Accuracy Class 0.05S
Allow long-term work under the rated current; More than120A across the core.
Precautions
The current of standard CT and tested CT must be the same in CT calibration.
Follow the given wiring diagram strictly.
Test whether the load box is accurate or not before calibrating the transformer.
Forbid secondary winding opening during the calibration.
Select demagnetization before calibration.The wiring diagram is shown in figure 5.
Short out the secondary winding before cutting off the power when the demagnetization is finished.
Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Product Introduction
Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer.
Product Parameters
Technical parameters
Rated Capacity 80kVA
rated voltage 160kV
Adjustable inductance range 65~130H
Rated frequency 50Hz
Rated current 0.5A
Adjustable gap range 0~300mm
In the process of semi finished and finished production of power transformers, before the newly installed transformers are put into operation and according to the state Grid's preventive test rules, it is required to test the transformer's turn ratio or voltage ratio regularly.The traditional variable ratio bridge operation is tedious, the reading is not intuitive, and the necessary conversion, the test result is only one phase change ratio value.The transformer transformer ratio tester overcomes the shortcomings of the traditional transformer ratio bridge test, the screen uses a large screen high resolution LCD screen, convenient to use in the field, with Chinese menu prompt function, simple and intuitive operation, a complete three phase change ratio test, test speed, high accuracy.
Technical parameter
range 0.910000
The accuracy of
reading 0.1 2 words or equal to 500
reading 0.2 2 words 500 3000
Reading 0.3 2 words 3000
The resolution of the
0.9 9.9999 0.0001 100 999.99 0.01 10000 and above 1
10 99.999 0.001 1000 9999.9 0.1
Working power supply AC220V 10 50Hz
Instrument weight 3.5kg
The use of temperature 10 50
Overall dimensions 260mm l 200mm W 160mmH
Relative humidity 90 no dew
Feature
Full three phase sinusoidal inverter output, the output voltage is automatically adjusted, with soft start, soft stop function, so the test speed is fast, high precision
Three-phase transformer, single-phase transformer, PT, Z type transformer ratio, group, polarity test function
Blind test function, that is, variable ratio and group test when high and low pressure connection mode is not known;
CT variable ratio polarity test function
Angle difference test function for single-phase test
2. We have abtained VDE,UL,CE,ISO9000 approval .we guarantee quality is the first.
Test process:
1). No-load test (included no-load voltage,no load current and no load loss)
2). IInductive voltage test
3). Load test (load voltage and temperature rise
4). Temperature rise test .
5). Insulated resistance
6).Hi-pot test
7).Leakage indutance test
8).DC resistance test
9).Surface inspection.
3.customized audio toroidal transformer and solar energy transformer Application:
Grewin Electrical Supply Toroidal Transformer with ISO9001: 2015
1). Application:
1. audio equipment
2. electric control
3. computer
4.instrument
5.telecommunications
6.high-end and middle-end vedio etc
2). Advantages:
1.High quality 100% copper core
2.a full range of toroidal transformer
3.Specially sales and technical services:5-10Years
4.With 14 years' producing history in transformer induatry
5.our company have cooperated with many customers around the world and gained good reputation at home and abroad.
3).Note
The above-mentioned toroidal transformer is frequently-used, we can also manufacture the products by customer design. And the specification is for reference, if has the change further, please take the material object as the standard.
4).GREWIN'S Dimension :
External diameter: 40mm-300mm, height :13mm-130mm, Efficiency: 75-98%
we can design the appropriate products according to customers' requirments such as installation dimension, input and output voltage,power...etc.)
4.product procedure
The following picture showed you about all finished toroidal transformer production line and package with export standard carton and strong pallets:
Grewin Electrical Supply Toroidal Transformer with ISO9001: 2015