Panoramic Dental X-ray machine YSX1005 Specialty: High voltage Generator, minimum radiation for patient. Patient positioning with chin rest and reference with bit Available for adult, children, left, right or frontal partial views and upper jaw joints, lower jawbone. Technology Parameters: 1. IEC classification: Class I, type BF 2. Power supply:230V 50/60HZ 10A 3. Mains resistance: ú+ 20ohm at 20V 4. X-Ray generator: Multi-pulse at 10kHz 5. Anodic Voltage:60-86KV Constant Potential . NW:200KG GW:250KG.
The high frequency dental X-ray unit consists of an inverter and HT section in a compact enclosure. It has been designed and developed for OEM application to be used for floor or wall mount systems. The high frequency output allows for lower kV per exposure, shorter exposure and superior imaging.
Adopt ceramic transducer. Automatic frequency trace. 5 tips. 220v 50hz, 2.1kg.
Controlled time with coms. Wide-scope voltage. Prolong the life of a lamp. 220v 50hz, 1.6kg.
Supplier: Medical equipment, ventilator, monitor, anesthesia machine, ecg, ultrasound scanner, dental x-ray unit, x-ray equipment, endoscope products, optoelectronic equipment, clinical lab equipment.
Supplier: Ultrasonic scaler, dental equipment, dental unit, x-ray unit, micromotor, prophy-mate, tips
Technical parameter 1. The numbers of x-ray tubes used in the product are also used as product numbers and x-ray generator (bulb tube head) numbers. 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltage (kvp) 60 65 70 X-ray current (ma) 0.50 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable. 6. Wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) 7.1. The parameter of x-ray tubes A. Focus index: 0.3í-0.3mm2 B. The voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5ví+0.5v, if=3a E. Target surface obliquity: 12íp F. The cooling manner of bulb tube head: oil immersion 7.2 the parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B. The thickness of filter-ray film: more than 1.5mmal C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
1) 220V power supply voltage of plus or minus 10% of Pathology 2) Rated 60W. Technical specifications Mainframe exterior size 280 * 200 * 80MM Ball-2009140 * Spiral (excluding Canada longituba) Weight 2.2kg mainframe Ball pounds Temperature 5-40 degrees Relative Humidity
Specifications: Tube Voltage): 60kV Tube Current: 1mA Exposure Time: 0.02~2S Tube Focus: 0.3*0.3mm Frequency: 30kHz Battery: DC14.8V 6400mA Rated Power: 60VA Charger Input: AC100V-240V±10% Charger Output:DC16.8V Weight:2.2kg Size:138*165*185mm The distance from skin to cone: 130mm