DIN-Rail Single Phase Energy Meter with Counter(DDS-1Y-M) Executive Standard: IEC62052-11 2003; IEC62053-21 2003 DIN-rail standard: "SO"43864. Function and characteristic: Long terminal block; Nameplate inside; Measure power accurately; Anti-creep. Technical Data: Rated voltage: 110V, 220V, 230V, 240V; Rated current: 5(30)A, 5(60)A, 10(80)A, 5(80)A; Frequency: 50-60Hz Connection mode: Direct type Display: Counter 6+1=999999.9kWh Accuracy Class: 1.0 Power consumption: Un1W (when 220V 20A) Start current: 0.004Ib Standard work temperature: -20-45degree. Crelative humidity: 85%. Size: 115*78*65mm.
Type: dds-1y-18m Current: 5(32)a, 5(40)a, 5(45)a, 5(50)a Voltage: 110v; 220v; 230v; 240v Accuracy: 1.0; 2.0 Constant: 1000imp/kwh Frequency: 50/60hz Connection mode: direct type;external ct type Display mode: counter 5+1 = 99999.9kwh Power consumption: n0.4w; n8va Start current: 0.004ib Din-rail standard: so43864 Executive standard: gb/t17215-2002; iec61036 120pcs/ctn. Carton size:50.2*40.5*19.5
Single Phase DIN-Rail Energy Meter (DDS-1Y-L) Executive Standard: IEC62052-11 2003; IEC62053-21 2003 and IEC62056-21(IEC1107) DIN-rail standard: "SO"43864. Function and characteristic: Single measurement(optional RS485 or RS485 Modbus) High accuracy of measure, convenient installation; Logical design of Anti-creep. Technical data: Rated voltage: 110V, 120V, 220V, 230V Rated Current: 1.5(6)A, 5(60)A, 10(100)A Frequency: 50-60Hz Connection mode: CT type; Direct type Display mode: LCD 5+2 = 99999.99kWh Accuracy Class: 1.0 Power consumption: 1W (when 220V 20A) Start current: 0.004Ib Constant: 12800 imp/kWh; 800/1600/3200/6400 imp/kWh Standard work temperature: -20-45 degree Climate work temperature: -30-55 degree Relative humidity: 85%. Size: 100*76*65 mm.
Product Description Major technical data: Accuracy class: 1.0 Power consumption: 20 years. Main functions: 1) Measurement of 50hz for 3-phase active power 2) 4 tariffs and 8 time periods for user's option 3) RS 485 communication functions 4) Manual and remote control program, and remote-metering functions 5) To record the parameters automatically through CMRI. Features: 1) High accuracy, reliability, overload capability 2) Low power consumption 3) Smt technology and re-flow soldering technology 4) Light weight, small size, easy to install. Model: DTSF318/DSSF318 Standard: IEC 62052-11 IEC 62053-21 IEC 62056-21 Productivity: 100.000pcs/year.
Single phase long life electronic energy meter Major technical data: Name of product: single phase long life electronic energy meters Type: dds 318 Accuracy class: 1.0 Power consumption :< 6va Rated voltage: 220v 240v Rated current: 2.5(10) a 5(30) a 10(50) a Application: By adopting advanced pcb and smt technology, dds318 single phase long life electronic energy meter is used to measure the energy of 50hz single phase a.C power. Salient feature: 1.High accuracy:1.0class 2.High overload capacity: 6 times of overload. 3.High reliability: long operating life. 4.Low power consumption, small size, light weight, tamper proof and easy to install. 5.Smt and re-flow soldering technology is adopted. Meter has strong capability for disturbance. Emc can comply with requirement of iec61036-2000. 6.With impulse output interface for direct calibration of the meterf+s accuracy, or for measurement of the impulse input in case of mass-metering. 7.Power indicator to test the optical power end and calibrate the accuracy of the meter. 8.Electric power line carrier system and telephone remote-metering system can be supplied for userf+s option. 9.It can be changed into single phase plc electronic energy meter
Features: 1) high accuracy, reliability, overload capability 2) low power consumption 3) smt technology and re-flow soldering technology Major technical data: 1) accuracy class: 1.0 2) power consumption: less than 4va 3) rated voltage: 200v 4) rate current: 2.5(10)a, 5(25)a, 10(40)a Main functions: 1) measurement of single-phase 50hz active power and power consumed 2) set up maximum load, overload warning and power off 3) warning of remained energy and remind user for payment 4) re-read power consumed, remained energy and number of prepayments for power 5) power off when no energy in the meter 6) parameter transferring through ic card Salient features: 1) high accuracy: 1.0 class 2) high overload: 6 times of overload 3) high reliability: long operating life 4) low power consumption, tamper-proof, light weight, small size and easy to install 5) register displays consumed power, and led displays status of consumed power 6) smt technology and re-flow soldering technology are adopted. Meter has strong Capability for disturbance. Emc can comply with requirement of iec 61036-2000 High overload capacity, high reliability of relay Single-phase and 3-phase pre-payment electronic energy meters can share one set Light weight, small size, easy to install Of prepayment control system
This product is portable design,used in field to check watt-hour meter error. Accuracy class:0.05. 6.4inch TFT COLOR LCD measured CT variable ratio 0-600V/1MA-12A Check wiring and calculation electricy of compensation.
DTSF22 Three Phase Four(Three) Wire Multi-tariff Electronic Meter are designed to satisfy industrial demand, adopting large-scale integration(LSI), digital sampling technology and surface mounting technology (SMT). It features stable functions, high precision and easy operation. The meter is capable of measuring active/reactive energy and demand in all directions, RS485 port communication, manual and infrared waking during power outage, load record and much more. It can check the battery to ensure the safety and stability of clock. The meter is popularly used by ordinary three phase clients, power plant, transformer substation, communities and main measurement point. 16units in a carton.
Product description Gf102 single phase energy meter testing set used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology. High voltage and current output . Widely used in lab and field. Features Meter under testing: 1p2w Testing mode: active power, reactive power Test 3pcs or 2pcs meter synchronously Starting test and creeping test Reference standard and power source integrated, easy to carry. Measuring mechanical meter and electric meter Operating by manual keyboard or pc With shortcut key of normal test point, speed up testing Internal large capacity storage device for mass memory Local checking the testing result Overload, short circuit, open circuit protection With self-checking function Technical data Voltage Test voltage output (phase-neutral) 0v ¡v 264v Power of the voltage output Max. 30va , 15va Resolution 0.01% Accuracy 0.1% , 0.2% Stability 0.02%/120s , 0.05%/120s Distortion factor < 0.3% for linear resistance load Current Test current output 1ma ¡v 120a , 1ma ¡v 60a Power of the current output Max. 100va , 30va Resolution 0.01% Accuracy 0.1% , 0.2% Stability 0.02%/120s Distortion factor < 0.3% for linear resistance load Phase angle Range 0 -- 360¢x Resolution 0.1¢x Accuracy 0.2¢x Frequency Range 45hz ¡v 65hz Resolution 0.005hz Pulse output High frequency output(ch) 1.666¡ñ105 hz Low frequency output(cl) 5¡ñ10-5¡ñch Pulse input Input channel 3 Input frequency Max. 20hz Other Voltage supply 220v¡ó10% 50/60hz¡ó2hz Ambient temperature -10¢xc -- +40¢xc Relative humidity 35% -- 85% Dimensions (w¡ñd¡ñh) (mm) 445¡ñ440¡ñ180 , 410¡ñ220¡ñ150 Weight (kg) 18 , 9.5 Dimensions (w¡ñd¡ñh) (mm) 445¡ñ440¡ñ180 , 410¡ñ220¡ñ150 Weight (kg) 18 , 9.5
Adopted special large-scale integrated circuit and manufactured with advanced SMT process, DT(S)SD22E Three Phase Four(Three) Wire Multi-function Electronic Energy Meter is featured whit high degree of measuring accuracy, reliable and stable performance, long service life, small cubage and low power dissipation and it usually can be used to measure power consumption at different time segment. And its standard infrared communication port and RS485 communication can realize functions of local meter reading, setting, clock setting and period program etc. Functions and Characteristics Positive/negative active energy consumption measurement, Positive/negative reactive energy consumption measurement and four tariff energy consumption measurement during latest 12 months Measurement of maximum demand and meter clearance... Two time zones, four rates, ten time periods. Event record of voltage/current missing, programming, demand clearance, outage etc. Load curve of current, voltage, power, energy. Real time data display: Time, voltage and current. Self verifying and monitoring of power supply, power network, operation situation of meter. Programming and reading can be realized via infra-red and RS-485 ports. Strong sound-and-light alarm function against abnormal incidents . 16units in one carton.