22000+ qty laptop batteries the battery life will be 85-90%
Supplier: Portable power station, resindential energy storage system, commercial & industrial energy storage system, mini grid solar energy solutions, solar panels, pv derivatives, lifepo4 battery, lithium battery, solar battery
Services: Samples, oem & odm service
Supplier: Solar products, solar appliances, home appliances, electric appliances, lithium battery, gel battery, hybrid inverter, solar lights, solar accessories, solar fan, power inverter, electric cooker, led tv, solar power station
Supplier: Laptops, desktops, computer pcs, printers, scanners, ups, led monitors, cisco networking products, storage and solutions, processors and memories, copier machines, cctv's, ubiquiti, perfumes, thermal rolls, a4 papers, stationery, perfume/ body spray
Basic Parameters Dimensions: 201 x 99 x 35 mm Weight: 333g Adapter Input: AC 100 ~ 240 V Output: DC 24V 2.65A Display mode Segment LCD with white backlight + LED in red and green Function Introduction Charge Active, pre-charge, constant current and constant voltages are the stages of charging mode. The initial charging mode depends on the battery voltage, so active and pre-charge don't happen to every batteries. For charging mode and current, please refer to the paragraphs of charging mode and charging current on page 2 & 3. Tester will stop charging if one of the conditions below was met. 1) Remaining capacity 99% & current intensity = 0 2) Remaining capacity = full charge capacity 3) Current intensity reduce to end charge current when constant voltage charge 4) Remaining capacity reach up the set value Discharge Constant current discharge for double loads Inner load: 0 ~ 1000mA, adjustable continuously via Battery Manager External load: 0mA, 500mA, 1000mA, 1500mA, 2000mA, five gears with dip switches offered Tester will stop discharging if one of the conditions below is met. 1) Remaining capacity set value 2) Voltage set value 3) Current intensity reduce to zero Remarks: Many batteries can not measure exact current intensity, which cause an else current value appears after you set a value. However, the actual discharging current is the same with your set value. Test Testing time is 12 seconds and the purpose is to check both the charging and discharging performances. After finishing test, LED flickers with green color and LCD reports the test result. Normal: Test OK Shown on LCD Abnormal: Test NG Shown on LCD Possible causes and solutions for the abnormal: 1) Cause: battery voltage is too low to discharge Solution: try to charge the battery to raise voltage 2) Cause: remaining capacity is too full to charge any more Solution: try to discharge the battery to reduce the remaining capacity 3) Bad contact of battery connecting wires 4) Damaged battery 5) Tester trouble Capacity Correction The battery capacity value in the battery management chip will different from the actual capacity after a battery goes through many recycling cycles. It will affect the use of the battery when the difference reaches a certain degree. Capacity correction is to deep discharge a battery and then fully charge, which will correct the capacity value in the battery management chip. Remarks: Discharging current can be set via Battery Manager. Deep discharge will cause a battery losing communication with tester, so battery dropping phenomenon may happen in the discharging process if the end capacity and voltage are set too low. In such a case, active charge will make the battery work again. 50% Capacity CD50%: charge firstly, and then discharge to 50% capacity DC50%: discharge firstly, and then charge to 50% capacity Online Functions Tester can be connected with master machine via a USB port. Users can monitor, control and set parameters via Battery Manager software in the master machine. Monitoring Battery information can be monitored via three windows. 1. Home screen Battery bar and brief information can be read on home screen. 2. Battery detail information window Show smart battery data in real time and the data can be saved and printed in image format. 3. Battery graph window Voltage, current and capacity are traced in curves. Control Battery Manager can control slave machine completely. Right-click menu on the battery bar includes the related commands. Attention All the functions of charge, discharge, capacity correction and 50% capacity are comply with the charging discharging conditions, which are showed on function introduction paragraph in page 4 & 5, so parameters should be set reasonably. Especially, deep discharge will cause a battery losing communication with tester. Others 1. Active cooling 2. Active batteries of zero voltage When a battery is deep discharged, the discharge protection circuit will start up and the voltage in the battery connector will become zero voltage. In this case, an appropriate voltage should be supplied to active the battery. 3. Battery identification Battery information can be read from battery management chip after establishing communication. 4. Intelligent protection Against over-current, over-voltage, over-charge, over-heat and short circuit. 5. Fan Discharging mode: fan startup Other modes: fan startup when temperature above 48 Fan stop working when temperature below 40 6. Trouble alarm LED flickers in red color and current command stops when one of the conditions below happen. 1). There is not current for around 50 seconds when charge. 2). There is not current for around 25 seconds when discharge. 3). Charging time is above 8.8 hours. 4). Discharging time is above 9.9 hours. 5). Suitable for almost all laptop batteries, above 95% Structure Accessories 1).1 * adapter 2). 1 * USB cord 3). 1 * CD 4). 13 * connectors 5). 10 * cables 6). 10 * jumpers 7). 1 * loader Standard Export Carton
Good battery Good service Product Information: ELL XPS L702x Series • Replaceable Battery Series: 312-1123 312-1127 J70W7 JWPHF R795X WHXY3 Delivery: • FOB Shenzhen • Lead Time: 3-10 days Warranty: • 14 months Laptop Battery for Dell XPS15 HYPT NO.: HY20179 Battery NO. : DELL XPS15 Type: rechargeable Li-ion Voltage: 11.1V Capacity: 6600mAh Standby time: 4-5hours Cells: 9 cells Dimension: 220.9*54.4*40.5mm Net Weight: 444G
02K7039,02K7040,02K7041,02K7043,02K7044,02K7046,08K8035,08K8036,08K8039,08K8040,08K804 5,08K8048, 92P1097 Replacement Models: Thinkpad X30-2672 Thinkpad X30 series Thinkpad X31 series Voltage: 10.8v Capacity: 6600mah Cells: 9 Model: x30h 6600mah 0 units in stock.
X40(H) 4400mah Compatible P/N: 92P0999 , 92P1000 , 92P1001 , 92P1003 , 92P1005 , 92P1009 , 92P1080 , 92P1119 , 92P1146 , 92P1148 , FRU 92P0998 , FRU 92P1002 , FRU 92P1078 , FRU 92P1143 , FRU 92P1145 , FRU 92P1147 , FRU 92P1149 Replacement Models: THINKPAD X40 SERIES ThinkPad X41 ThinkPad X41 1864 ThinkPad X41 1865 ThinkPad X41 2525 ThinkPad X41 2526 ThinkPad X41 2527 ThinkPad X41 2528 ThinkPad X41 Series Voltage: 14.4v Capacity: 4400mah Cells: 8 Model: x40(h) 4400mah 0 units in stock.
Compatible P/N: FRU 92P1082 , FRU 92P1083 , IBM 73P5167 Replacement Models: IBM ThinkPad X41 Tablet 1866, IBM ThinkPad X41 Tablet 1867, IBM ThinkPad X41 Tablet 1869, IBM ThinkPad X41 Tablet Voltage: 14.4v Capacity: 4500mah Cells: 8 Model: x41t. 0 units in stock.