Electromagnetic Flowmeter model No FMF 2500 Manufacturing Unit in Coimbatore
System Information The electromagnetic flow meter HMF 2110 series is the most common and highly accurate flow measurement device that can be universally used in various measurement fields. Since there is no driving part like a propeller, no trouble is caused due to pressure loss, and the durability is excellent In addition, since the installation is simple with the flange type, even a beginner can easily install it through simple training. The sensor measures the flow rate by direct contact with the fluid,, thus a more reliable flow rate value can be obtained, and the reproducibility is also excellent If you are looking for a flowmeter that can be used with confidence, choose the HMF 2110 series without hesitation. â?? KEY FEATURES Quick Start Self diagnostic Easy Maintenance â?? CHARACTERISTICS â?¢ Due to high stability, popular for water flow measurement â?¢ Excellent durability due to no driving part â?¢ Electrode and lining materials are selected for measuring chemical flow â?¢ There is no pressure drop, which reduces electricity costs. â?? SPECIFICATIONS * Sensor installation method : Flange mounting type (Standard: JIS, DIN, ANSI, etc.) * Accuracy : �±0.2% (flow rate 0.1 m/s or more)0.2% (flow rate 0.1 m/s or more) * Max Minimum Flow : 0.05 m/s ~ 10 m/s (Flow rate by diameter) * Measuring pipe caliber : 6 mm ~ 2,000 mm * Measurable fluid : Water, sewage, wastewater, chemicals, etc. (Conductivity of 5�¼S /cm or more) * Power : 110 ~ 220 V AC / 60 Hz * Operating temperature : Sensor (40 ~ 70 â??), Operation: (18 ~ 60 â??) * Screen display contents : LCD Size: LCD Display 100 x 55, 3 Line, 16 Characters, Instantaneous flow rate (4 digit), accumulated flow rate (9 digit), pressure (4 digit) * Flow display unit : Unit: m3, L, etc. / Directions: Forward & Reverse (-) * Electrode : Hastelloy C * Liner: NBR, Hard Rubber, EPDM * Flange : Carbon Steel * Flow measurement frequency : 1.875 ~ 12.5 Hz * Sensor cable length : 100m * Output signal : 4 ~ 20 mA, Integrated pulse active , Passive (Max 10 kHz), Relay pulse (Max Load 24 V DC / 1A) * Communication and memory : RS 232, RS 485 Modbus 128 Mbyte internal memory: date, time, instantaneous flow rate, accumulated flow rate, Pressure memory interval: 5 seconds ~ 24 hours * Protection class : Sensor unit: IP 68 / Operation unit: IP 65 * Self diagnosis function : Alarm display when empty pipe information and self diagnosis error occur For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
Description - "it Is A Flowmeter For Measuring Fluid Flow Rates In An Enclosed Conduit. It Has The Karman's Vortex That Is Proportioned To The Velocity Of Fluid In The Down Stream Of Trigonal Prism (delta Body). " Origin - Korea Size - 15a ~ 300a "packaging Details (w*d*h)/mm" - 500*300*200 Weight(kg) - 3 ~ 20 FOB ($) - " Retail Price + (Shipping Cost) " MOQ - 1set NOTE - All the product information may be changed depending on the specification.
LUGB type vortex flowmeter is according to the principle of Carmen (Karman vortex street measuring gas, steam or the volume of liquid flow, the volume of the standard condition or volume flow to mass flow meter. And can be used as flow transducer is applied to automatic control system.Vortex flowmeter can be divided according to function name gas flow meter,flue gas meter,steam flow meter,gas flow meter,compressed air flow meter,liquid flow meter. The instrument adopts the advanced differential technology, cooperate the measures such as isolation, shielding, filtering, overcome the similar products such problems as poor vibration resistance, small signal data disorders, using a unique sensor encapsulation technology and protective measures, to ensure the reliability of the product. Products are both basic and compound type, basic measuring single traffic signal; Compound can be realized at the same time temperature, pressure, flow rate measurement. Each type has overall, fission structure, in order to adapt to different installation environment. Vortex flowmeter classification: LUCB series plug-in vortex flowmeter, LUCB series of vortex flowmeter is mainly used for industrial piping medium fluid flow measurement, such as gas, liquid and vapor, and other media. Is characterized by small pressure loss, wide range, high precision, working condition of the measurement volume flow is almost not affected by the fluid density, the influence of the parameters such as pressure, temperature, viscosity. No moving mechanical parts, so high reliability, small amount of maintenance. Instrument parameters can be long-term stability. Vortex street flowmeter using piezoelectric stress sensor, high reliability, can be in - 20 ~ + 250 temperature range. There are standard signal simulation and digital pulse signal output, easy with the computer and digital systems, is a more advanced, the ideal flow meter.
0 integrated / split electromagnetic flowmeter using the latest advanced technology and intelligent measurement algorithm, not only can measure low-conductivity liquid, can also be measured acid, alkali, salt and other corrosive liquids. Widely used in chemical fiber, food, mining and metallurgy, environmental protection, steel, petroleum, pharmaceutical and other fields. The innoMag 300 electromagnetic flowmeter consists of an electromagnetic flow converter and an electromagnetic flow sensor that can be used to measure and record the volumetric flow of conductive fluids. Using the latest advanced technology and intelligent measurement algorithm, not only can measure low-conductivity liquid, can also measure acid, alkali, salt and other corrosive liquids.
[ CHARACTERISTICS ] ¶Wide Beam Transducer (Broadband ultrasonic measurement function) ?¢ Determine the transmission frequency by finding the resonance frequency of the pipe according to the outer diameter, material, and thickness of the pipe â?¢ Little error occurs due to stable signal reception â?¢ Excellent measurement stability even when there are air bubbles slurry (30% or less), scale generation, changing temperature and density. How to install â?¶Pipe Configuration (automatic correction of disturbance factors) â?¢ In actual industrial sites, sufficient straight pipe without interference is required for accurate flow measurement â?¢ If no sufficient straight pipe is secured ; * HUF 2000N / HUF 2000DN (Compensation Type Ultrasonic Flow Meter) - Re estimation of correction factors for disturbance factors and distances from disturbance factors, self compensation. - It has the same accuracy as that in which a sufficient intuition is secured even at a short distance from the disturbance factor. â?¶Other Functions * Diagnostic Menu (Self diagnosis function) The attenuation degree, correlation degree, and noise degree of the ultrasonic received signal can be known and quantified to display empty pipe information, strength of the received signal, bubble content, S/N ratio, etc. * Auto Zero (Automatic zero adjustment function) In the first installation, zero point can be automatically adjusted without stopping the flow. Periodic automatic zeroing can prevent zero deformation caused by other factors. * MultiPulse Transmission (Multi pulse function) The pulse signal to analyze the time difference waveform transmit 50 pulse signals per measurement cycle, thus it has excellent measurement sensitivity and stability of ultrasonic signals. * Liquid Class Menu (Fluid selection function) A list of about 30 types of fluids is provided. When selecting fluids, the expected ultrasonic velocity (m / s), viscosity ( cS ), density (SG), and data are automatically entered and the pipe temperature range can be selected. Pipe Data Menu (Pipe selection function With more than 40 types of standard pipes and custom pipes built in, you can enter pipe outer diameter, material, and thickness using a list of pipe class and size options.
SKLD type electromagnetic flowmeter is the intelligent electromagnetic with research and development, which adopts domestic and foreign advanced technology. Electromagnetic transducer with high-speed central processing unit (CPU) and the features of rapid computing speed and high precision, reliable performance measurement are in both Chinese and English menu.Electromagnetic flowmeter is divided into one type of electromagnetic flowmeter and split electromagnetic flowmeter,Insert electromagneticflowmeter. Electromagnetic flowmeter can be divided according to the use of function:liquid flow meter,water flow meter,sewage flow meter,Intelligent electromagnetic flowmeter,explosion-proof flow meter,irrigation flow meter,mud flow meter Sensor uses non-uniform magnetic field technology and special magnetic circuit structure. Magnetic field is stable and reliable, and the circuit structure reduces the volume, The sensor can reflect the traffic change timely and effectively, and have a stable value of measuring water, sewage, slurry, pulp, acid, alkali, salt slurry liquid and food, etc. There are lots of wide applications in the petroleum chemical industry, metallurgy, coal, water conservancy project of water supply and drainage, sewage treatment etc. The electromagnetic flowmeter has two types: the compact and the sensor for remote transmitter.
Turbine flowmeter can be divided according to function name gas flow meter,flue gas meter,steam flow meter,gas flow meter,compressed air flow meter,liquid flow meter. LWG type turbine flow sensor and receiving electrical signals of the display instrument of turbine flowmeter, which is used to measure low and medium viscosity closed pipes Degree of fluid (liquid or gas), the total volume flow and in petroleum, chemical industry, metallurgy, aviation and scientific research departments for a wide range of applications. Sensor is composed of turbine sensor components and amplifier, the structure of the two together for one-piece: to measure the structure of the positive and negative flow For two-way type; With inserted rod can be installed in the large diameter pipe flow body flow structure for a plug-in. Based on the principle of moment balance sensor work. When the fluid flows through the sensor, promote the impeller rotation, when the flow rate must be dynamic torque Maintain and drag torque balance, the impeller speed. Evenly distributed on the permeability of the impeller blade with the impeller rotation, to periodically change detection The reluctance of the magnetic field sensor (coil), electrical pulse signal detector, after the amplifier amplification output. The output electric pulse frequency and impeller speed Is proportional to the impeller speed is proportional to the flow in, so the output electric pulse frequency is proportional to the flow sensor flow, 4-20 ma signal is converted is proportional to the flow.
Aliavtx avf7000 is a vortex flowmeters based on von karman theory of vortices generated by a bluff body in the pipe. The number of vortices are linearly proportional to the volumetric flow in the pipe. The avf7000 is versatile flowmeter widely used for gases, steam & liquid applications. There are no moving parts and comes with either Flange or wafer connection. Standard configuration comes with local indication for flowrate and total flow as well as a 4-20ma output function output. The electronics are designed to filter out erroneous signals as well as noise due pipe vibration. Features Simplified setup and diagnostic functions. Auto. Temperature & pressure compensation 4-20 ma and pulse outputs, user selectable. A very wide selection of sizes. Wide temperature range of up to 420 deg. C. Non-volatile memory for setup and calibration. Specification Size:10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500mm Material: Stainless steel 301 / 304 / 316 Accuracy: Liquid:+/- 0.7% of reading Gas & steam:+/- 1.0% of reading Process connection: Flange / wafer Flanges type: Jis 10k / jis 20k / jis 40k Ansi 150# / ansi 300# / ansi 600# Din pin 10 / pn 16 / pn25 / pn 40 Temperature: -40 ~ +280 deg. C (standard) -40 ~ +420 deg. C (optional) Protection: Ip 65 Explosion proof, exd iic t6 Intrinsically safe, e ex ia iic t4 Local display: 4 lines lcd 4 digit flowrate 8 digit totalizer Communication: Rs485 Standard