**Ready stock in Turkey** -Price: USD11,000/CIF by air *without compressor -Price: USD12,000/CIF by air *with compressor -Operation Features- Inspiration Pressure: 2-100 mBar Inspiration Duration: 0.1-10 Sec. Peep Pressure: 0-50 mBar Breathe Speed: (c) 1-150/mins. (y) 1-100/mins. Flow: (c) 1-60 lt/mins. (y) 2-120 lt/mins. O2 Mixture: 21-100% Spontaneous Pressure Support: 0-100 mBar I/E Rate: 1:10 (x60*)-10:1 (c): Child, (y): Adult
Tidal Volume:20-2500ml Display:10.4 TFT touch screen Type:pneumatically driven tronic control Gas supply:medical o2, medical air Pneumatic system safe pressure:125cmH2O Power supply:AC 110-240V, 50-60 Hz Battery:Lithium battery, backup for more than 2 hours Product Size:H400mm* W303mm * L250mm Weight: 16kg HS code:9031809090
ARIES 2500 Anesthesia Machine: Display: 10.4 TFT color screen Application: Adult, Pediatric Driven mode: Pneumatically driven electronically controlled Mode: Semi~open, Semi~closed or closed system Anesthetic vaporizer: two high precise vaporizers Power supply: 220V,10%, 50Hz,1Hz 10V,10%, 60Hz,1Hz Internal battery: DC12V (4 working hours) Fresh gas outlet is in front of frame Anesthesia Ventilator: Respiration mode: IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY, DEMO Waveform: P-t, F-t, V-t, F-v, V-p Tidal Volume: 20~1600ml Respiratory frequency: 1~65bpm I:E ratio: 4:1~1:4 Inspiration pause: 0~55%Ti Inspiration Pressure: 1~60cmH2O Trigger Pressure: -20~20cmH2O Monitoring parameters: O2 concentration, MV, Respiratory frequency, Tidal volume, Ppeak, PEEP, I:E ratio, Pmean, Compliance etc.. Alarm parameters: high pressure alarm, low pressure alarm, O2 concentration alarm, MV alarm, O2 source failure alarm, AC power failure alarm, etc. Pressure alarm setting: High pressure alarm set 1~60cmH2O. Low pressure alarm set 0~20cmH2O O2 concentration alarm setting: high: 21~99%. Low: 21~50%. MV alarm setting: MV high alarm set 10~99L/min MV low alarm set 0~40L/min Main Unit: Circle absorber: Compact circle absorber Flow meter: Five~tube flow meter O2 tube: 0L/min~1L/min~10L/min. N2O tube: 0L/min~1L/min~10L/min. Air tube: 0L/min~10L/min O2 and N2O Linkage Device, keep oxygen concentration not lower than 25% Oxygen flush: 25L/min~75L/min Gas source pressure: O2: 0.25Mpa~0.65MPa N2O: 0.25Mpa~0.65MPa Air: 0.25Mpa~0.65MPa Gauge: 4 units, 2¡ÁO2£¬N2O, Air.
Special Feature: Ventilation method: Closed, half-closed, half-open Small and compact unit ideal for office based anesthesia Two-gas machine( N2O&O2 ) Mechanical Anti-Hypoxic Device and O2/N2O interlock External CO2 circle absorber system Vetilator (option): TH-1, TH-1 A Main Unit: Tidal volume( Manual Mode): 20 ~ 1500ml Gas pressure: 0.25 ~ 0.65Mpa Flowmeter: O2 :0.1 ~ 10L/min N2O:0.1 ~ 10L/min APL valve: 0.5 ~ 6.0Kpa O2 Flush: 25 ~ 75L/min Ventilator TH-1 Special Feature: Driven mode: Pneumatically driven electronically controlled Display: High light LED display Ventilation mode: IPPV and Manual mode Tidal volume: 50 ~ 1500ml Breath frequency: 1~ 90Bpm I:E ratio: 4:1 ~ 1:6 Monitor parameter: Tidal volume, breath frequency, MV, airway pressure Alarm: MV high alarm£¬MV low alarm, TV high alarm, TV low alarm Ventilator TH-1(A): Special Feature: Respiration mode: IPPV, SIMV, MAUAL Display: 5.5¡¯ SNT screen Waveform: P-t, V-t Tidal volume: 50 ~ 1600ml Breath frequency: 1~ 65Bpm I:E ratio: 8:1 ~ 1:8 Alarm parameters: High pressure alarm, Low pressure alarm High pressure alarm limit: 20 ~ 60cmH2O Low pressure alarm limit: 0 ~ 20cmH2O Monitor parameter: Tidal volume, MV, Ppeak, PEEP, respiratory frequency, I:E ratio Safety valve pressure limit: 6Kpa Good air tightness, high reliability, and minor respiration impedance.
Special Feature: Application: Adult, Pediatric Driven mode: Pneumatically driven electronically controlled Mode: Semi-open, Semi-closed or closed system Anesthetic vaporizer: One vaporizer Anesthesia Ventilator: Display: High light LED display Ventilation mode: IPPV and Manual mode Tidal Volume: 50 ~ 1600ml Breath frequency: 1 ~ 90BPM I:E ratio: 4:1 ~ 1:6 Monitor parameter: Tidal volume, breath frequency, MV, Airway pressure Alarm: MV high alarm, MV low alarm, TV high alarm, TV low alarm Main Unit: Circle absorber: Compact circle absorber Bellow: 50 ~ 1600ml Oxygen FLUSH: 25L/min ~ 75L/min Flow meter: O2, N2O two-tube flowmeter O2 tube: 0L/min ~ 10L/min N2O tube: 0L/min ~ 10L/min O2 and N2O linkage device Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% ) Gas source pressure: O2: 0.25 ~ 0.65Mpa N2O: 0.25~ 0.65Mpa Gauge: 2 units, one N2O, one O2.