BOSTON SCIENTIFIC NC QUANTUM APEX PTCA DILATATION CATHETER
We Can Supply Boston Scientific Coyote Over The Wire Pta Balloon Dilatation Catheter H74939186201010 Please Don't Hesitate To Contact Us In Case Of Any Interested
Supplier: Latex surgical & exam. gloves, latex o.b. gloves, latex long cuff gloves for industrial grade, latex male catheters, latex penrose tubing, nitrile exam, gloves, nitrile gloves for industrial grade, wound dressings, medical tapes, face masks
1) More options in diameter ranges(CTO: 1.0mm-1.25mm; SC:1.5mm-4.0mm & NC: 2.0mm-5.0mm ); 2) More choices in balloon length (CTO &SC: 10mm-30mm; NC:8mm-18mm ) 3) Higher Rated Pressure (16atm for CTO& SC; 20-22 atm for NC); In addition, the average balloon burst pressure for NC reaches 35-40atm 4) Special hydrophilic coating on balloon, dismal shaft and tip, which made our frictional coefficient merely half of competitors' 5) Better flexibility thanks to Pebax-made balloon 6) Extraordinary minor balloon axial growth(3%) while inflation and 5F guiding cathether compatible 7) Tip Entrance Profile is 0.016'', Crossing profile for 3.0mm-diameter balloon is 0.0355''
BOSTON SCIENTIFIC MAVERICK MONORAIL DILATATION CATHETER H7493892815200 BOSTON SCIENTIFIC MAVERICK MONORAIL DILATATION CATHETER H7493892820200 BOSTON SCIENTIFIC MAVERICK MONORAIL DILATATION CATHETER H7493892815250
BOSTON SCIENTIFIC QUANTUM MAVERICK DILATATION CATHETER H7493808012300 BOSTON SCIENTIFIC QUANTUM MAVERICK DILATATION CATHETER H7493808012350 BOSTON SCIENTIFIC QUANTUM MAVERICK DILATATION CATHETER H7493808012250
ABBOTT MINI TREK CORONARY DILATATION CATHETER
PTA scored balloon dilatation catheter (abbreviated as balloon catheter) is composed of a tip, a marker ring, a balloon, a metal scored stent, a welded tube, an elastic connecting tube, an inner tube, an outer tube, a catheter reinforcement tube and a catheter seat. The surface of the balloon catheter is coated with a hydrophilic coating, and the hydrophilic coating covers a length area of 400 mm �± 50 mm from the outer tube connected to the elastic connecting tube to the position of the catheter reinforcing tube . PTA scoring balloon dilatation catheter positioning global products, we gradually follow up planning to sell to the European Union, users are needed for the peripheral vascular system ( including the iliac artery, femoral artery, iliofemoral artery, iliac artery, inferior iliac artery and renal artery ) Patients undergoing percutaneous transluminal angioplasty (PTA) surgery are suitable for the treatment of occlusive lesions of arteriovenous fistula for autologous or artificial dialysis