As for Urine Reagent Analysis Strip Uncut Sheets , we have various parameters ranging from 1 to 12 . We can provide you strip and uncut sheet URS format with high quality and competitive price PRINCIPLE AND EXPECTED VALUES URS Ascorbic acid: This test involves decolorization of Tillmann's reagent. The presence of ascorbic acid causes the color of the test field to change from blue-green to orange. Glucose: This test is based on the enzymatic reaction that occurs between glucose oxidase, peroxidase and chromogen. Glucose if first oxidized to produce gluconic acid and hydrogen peroxide in the presence of glucose oxidase. The hydrogen peroxide reacts with potassium iodide chromogen in the presence of peroxidase. The extent to which the chromogen is oxidized determines the color which is produced, ranging from green to brown. Low amounts of glucose are normally excreted in urine.3 Glucose concentrations as low as 100 mg/dL, read at either 10 or 30 seconds, may be considered abnormal if results are consistent. At 10 seconds, results should be interpreted qualitatively. For semi-quantitative results, read at 30 seconds only. URS Bilirubin: This test is based on azo-coupling reaction of bilirubin with diazotized dichloroaniline in a strongly acidic medium. Varying bilirubin levels will produce a pinkish-tan color proportional to its concentration in urine. In normal urine, no bilirubin is detectable by even the most sensitive methods. Even trace amounts of bilirubin require further investigation. Atypical results (colors different from the negative or positive color blocks shown on the color chart) may indicate that bilirubin-derived bile pigments are present in the urine specimen, and are possibly masking the bilirubin reaction.
Supplier: Fetal bovine serum, bovine bile, serum bovine adult, horse serum, rabbit serum, goat serum, porcine serum
Supplier: Ox bile powder, halal bovine gelatin powder, and bovine collagen powder,
Buyer: Food ingredients
Product Details: Brand : Boditech Med Incorporated Size : 25 T Samples : Human serum/plasma/control Specimen volume : 50 Microliter stored at 4 - 30 DegreeC Cat No : CFPC-89 INTENDED USE : ichroma AMH is a fluorescence Immunoassay (FIA) for the quantitative determination of AMH (Anti-m�¼llerian hormone) in human serum/plasma. It is useful as an aid in management and monitoring of premature ovarian insufficiency, menopause and ovarian reserve.For in vitro diagnostic use only. COMPONENTS : ichroma AMH consists of cartridges, detectors and diluent The cartridge contains the membrane called a test strip which has streptavidin at the test line and chicken IgY at the control line. All cartridges are individually sealed in an aluminum foil pouch containing a desiccant in a box The detector has 2 granules containing anti human AMH-fluorescence conjugate, anti-chicken IgY-fluorescence conjugate, anti-human AMH-biotin conjugate, bovine serum albumin (BSA) and sucrose as a stabilizer, MAB33 as a blocker in Tris-HCl buffer. All detectors are packed in a box The diluent contains bovine serum albumin and NaCl as a stabilizer, tween 20 and CA-630 as a surfactant and sodium azide as a preservative in phosphate buffered saline (PBS), and it is pre-dispensed in a vial. The diluent is packed in a box. PRINCIPLE : The test uses a sandwich immunodetection method; the detector antibodies in buffer bind to antigens in the sample, forming antigen-antibody complexes, and migrate onto nitrocellulose matrix to be captured by the other immobilized-antibody on test strip.More antigens in sample will form more antigen-antibody complexes which lead to stronger fluorescence signal by detector antibodies, which is processed by instrument for ichroma tests to show human AMH concentration in the sample. INTERPRETATION OF TEST RESULT : The instrument for ichroma tests calculates the test result automatically and displays AMH concentration of the test sample in terms of ng/mL The working range: 0.02- 15 ng/mL
Product Details: Brand : Boditech Med Incorporated Size : 25 T Specimen : human serum/plasma Specimen volume : 50 Microliter Cat. No. : CFPC-47 INTENDED USE : ichromaâ?¢ Vitamin D is a fluorescence Immunoassay (FIA) for the quantitative determination of total 25(OH)D2/D3 level in human serum/plasma. It is useful as an aid in management and monitoring of regulating the concentration of calcium and phosphate in the bloodstream and promoting the healthy growth and remodeling of bone.For in vitro diagnostic use only. PRINCIPLE : The test uses a competitive immunodetection method. In this method, the target material in the sample binds to the fluorescence (FL)-labeled detection antibody in detection buffer, to form the complex as sample mixture. This complex is loaded to migrate onto the nitrocellulose matrix, where the covalent couple of 25(OH)D3 and bovine serum albumin (BSA) is immobilized on a test strip, and interferes with the binding of target material and FL-labeled antibody. If the more target material exists in blood, the less detection antibody is accumulated, resulting in the less fluorescence signal. STORAGE AND STABILITY : The cartridge is stable for 20 months (while sealed in an aluminum foil pouch) if stored at 4-30 C. The detection buffer dispensed in a vial is stable for 20 months if stored at 2-8 C. The releasing buffer dispensed in a vial is stable for 20 months if stored at 2-8 C. Opened detection buffer and releasing buffer are stable for 12 months at 2-8 C if kept capped in original container and free from contaminations. After the cartridge pouch is opened, the test should be performed immediately. MATERIALS SUPPLIED : REF CFPC-47Components of ichroma Vitamin D Cartridge Box:- Cartridges 25- Sample Mixing Tubes 25- ID Chip 1- Instruction For Use 1 Detection Buffer Vial (3 mL) 1 Releasing Buffer Vial (2 mL) 1
Product Name Fecal Occult Blood(FOB)Test Kit (Colloidal Gold Method) Purpose To detect the content of FOB in human fecal in vitro qualitatively.For Professional Use only. Principles of Detection The FOB Rapid Test is a one-step chromatographic sandwich immunoassay. The test consists of: 1) a conjugate pad containing HB monoclonal antibody conjugated with colloidal gold. 2) a nitrocellulose membrane strip containing a test line (T line) and a control line (C line). The T line is pre-coated with another HB antibody, and the C line is pre-coated with a control line antibody (goat-anti-mouse IgG antibody). After addition of the sample, FOB will bind with a colloidal gold-labeled antibody on the conjugate release pad. The resulting complex flows over the nitrocellulose membrane where a specific capture reagent is pre-coated and a red line can be seen at the test zone (T). Unreacted colloidal gold-labeled antibodies in the sample are captured at the control zone (C). The intensity and speed at which the color develops depend on the FOB concentration in the sample. Reference range This kit can detect FOB at a minimum of 50ng/ml. Performance Characteristics 1. Critical value and repeatability: 1) The quality control substance of FOB with a concentration of 50ug/mL was detected for 20 times, and the positive coincidence rate was â?¥95%, and the color uniformity, and the reaction results were consistent. 2) The quality control substance of FOB with a concentration of 10ng/mL was detected for 20 times, and the negative coincidence rate was â?¥95%, and the color uniformity, and the reaction results were consistent. 2. Analysis specificity: 500ug/mL bovine HB,500ug/mL pork HB,500ug/ mL chicken HB,500ug/mL goat HB,2000ug/mL Horseradish Peroxidase specific quality control substance were all negative. 3.HOOK effect: human FOB positive quality control substance of 2000ug/mL was detected and the result was positive.
WONDCON Veterinary Anesthesia Machine WMV680D Equine Anesthesia Machine is designed for use with Equine. Bovine. Zoology. and other large animal anesthesia techniques PRODUCT DETAILS Feature: Respiration mode:Manual.open.closed.semi-open and semi-closed mode Gas source:O2.0.3--0.4Mpa O2 Flush:25L/min- -75L/min Flow meter:high precision O2 flow meter. 0--1L/min--10L/min. O2&N2O or O2&N2O two tubes flow meter is option. CO2 circle absorber: With soda lime chamber. APL valve. airway pressure gauge. inspiration valve and expiration valve. the inspiration and expiration valve is demo-type and visible. Airway pressure gauge: -20cmH2O--100cmH2O &-2Kpa--10Kpa APL valve:adjustable easily. range:0-60cmH20 Soda lime chamber: 8Liter. it is easy to change soda lime and used for over 1000kg animal Three methods: Table top and trolley and wall mounting arm. trolley is optional and wall mounting arm is optional Bains connector: It is used for open breath circuit. connect with Jackson breath circuit or bains breath circuit. Back bar: Supply selectatec compatiable mounting bar.ISO 23mm is compatiable Anesthesia vaporizer: TEC3 vaporizer. Enflurane. Isoflurane. Halothane. Sevoflurane. one vaporizer with selectatec compatiable mounting bar. Cage mounting vaporizer is compatiable. Trolley: There is a trolley to transport it.The trolley is optional. Tidal Volume: 5000-15000ml Standard configuration Anesthesia machine with vaporizer,Disposable breath circuit,� Reserve bag O2 gas source pipeline,Stand Optional configuration Animal mask ,Bird mask ,Laryngoscope Endotracheal intubation Rescue and Resuscitation,Bains breathing circuit,T-piece anesthesia breathing circuit Reusable breathing bag,Disposable absorber of anesthesia exhaust gas Anesthesia ventilator, ETCO2 monitor ,SPO2 monitor Patient monitor,Oxygen concentrator Oxygen concentrator-anesthesia machine Stand, Anesthesia machine-ventilator stand Induction Chambers