1,Advanced shock wave generator systems : In cooperation with Stuttgart University, a self-focusing electromagnetic shock wave generator systems with Wide Focus and Low Pressure has been used, lessening energy loss. 2,Acurate Localization:With suspended head , Ultrasound localization be easier. 3,Longer therapy depth: With a 145mm therapy depth ,the treatment of the Obesity be more easy. 4,Wider focus:A wider focus(18x180mm, 30.5 cu mm)make the breakage more efficient. 5,Lower pressure:Under the range of 7.0-10.5KV,one can feel less pain or even painless. 6,Turbulent degassing cooler system:With the system reducing the cost of consumables, the device became more durable. Range of discharge voltage: 7.0¡ª10.5kV Lateral diameter of focus area: ¡À10mm Triggering mode: manual, auto., respiration. ECG Therapy depth: 145mm Lifetime of therapy head: 1000000times Movements of therapy bed in 3D: 100mm in Y direction 140mm in Z direction 100mm in X direction Rotation of US localization system around therapy head:360¡ã Packing: crate.
1,Advanced shock wave generator systems : In cooperation with Stuttgart University in German, a self-focusing electromagnetic shock wave generator systems with Wide Focus and Low Pressure has been used in the device, lessening energy loss. 2,Advantage: Non-invention Non-anesthesia Easy treatment Less time required Compact and Movable Specifications: Therapy distance 60¡À10%mm Penetrating depth 0-100mm Range of energy in focus area 0.04-0.5mj/mm2 Frequency of shock wave release 0.5-2Hz Power supply 220V¡À10% 50Hz 1.0kVA Lifetime of therapy head: 1000000 times.
1,Acurate Localization:With appended head , Ultrasound localization becomes easier. 2,Longer therapy depth: With a 135mm therapy depth ,the treatment of the Obesity becomes more convenient. 3,Wider Aperture:A wider Aperture(200mm)gives more energy in breaking stones. 4,Lower pressure:Under the range of 3.5-6.5KV,one can feel less pain or even painless. 5,demountable electrode holder:It allows you to change the electrode more easier without draining the water and uncovering the cushion. Specifications: Range of discharge voltage 3.5-6.5kV Peakpressure 20-50MPa Lateral diameter of focus area 10-15mm Discharge energy 12-36J Discharge energy 12-36J Front of the peak pressure pulse ¡Ü0.2¦ÌS Width of half peak pressure ¡Ü1.0¦ÌS Triggering mode manual, auto., respiration and ECG Life time of the electrode ¡Ý4000 times Movements of therapy table 100mm in Y direction 100mm in X direction 140mm in Z direction Rotation of US localization around therapy head 360.
Ultrasound therapy unit Description Ultrasound therapy 1 and 3 Mhz clinical use Digital with LCD Deluxe Model Metallic Body Manarti 1 and 3mhz frequency Pulsed and continuous therapy operation 10%, 20%, 50% and 100%veriable duty cycle output of 16hz, 48hz, or 100hz. Clinical protocols, the most appropriate application and parameter set for the patientâ??s condition. light weight designs for clinic, hospital and home visits. auto detection of ultrasound applicator. micro controller-based design for optimum accuracy. Soft touch buttons. timer 0-30 minute put power is up to 2. 5 watts / cm2, which is controlled digitally back light LCD display
IFT Machine Digital Pre-programmed Description Digital I.F.T unit is an advanced electro therapy requirement unit micro-controller circuit. Its digital display system indicates output current intensity and treatment time. Technical Specification Base 0-150 Hz Sweep 0-100 Hz Carrier Frequency 4, 2 Hz Therapy modes 4 Pole, 4 Pole vector, 2 Pole Output Current 0-100 mA Timer 0-99 minutes
DESCRIPTIOn: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT: 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY : Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND counter Balance Mobile
DESCRIPTION: Titanx RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Floor to Ceiling Column Stand
DESCRIPTION: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Counter Balance Mobile
DESCRIPTION- TITANX 100 RADIOGRAPHY RATING- 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT 8KW RECTIFICATION- Full Wave Rectified TIMER- 0.06 to 5 sec DIGITAL DISPLAY- Digital Display of mAs, kV & mA X-RAY TUBE- XD-3/Imported POWER SUPPLY- 230 Voltage AC, 15 Amps LINE REGULATION- 10% 0.6max PROTECTION- Electronic overload Protection TUBE STAND- Spring Balance