Please click here to check who's online and chat with them.

Besco

Supplier From China
Dec-31-20
Supplier : Anesthesia equipment

Established: 2020

Verification Status



Contact Details:
China
-
China


Recent User Reviews

This user has not received any reviews yet!
 
 
Contact Supplier
Renew

More Items Similiar to: Besco

Dec-07-11
 
ARIES 2500 Anesthesia Machine:

Display: 10.4 TFT color screen
Application: Adult, Pediatric
Driven mode: Pneumatically driven electronically controlled
Mode: Semi~open, Semi~closed or closed system
Anesthetic vaporizer: two high precise vaporizers
Power supply: 220V,10%, 50Hz,1Hz
10V,10%, 60Hz,1Hz
Internal battery: DC12V (4 working hours)
Fresh gas outlet is in front of frame

Anesthesia Ventilator:
Respiration mode: IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY, DEMO
Waveform: P-t, F-t, V-t, F-v, V-p
Tidal Volume: 20~1600ml
Respiratory frequency: 1~65bpm
I:E ratio: 4:1~1:4
Inspiration pause: 0~55%Ti Inspiration Pressure: 1~60cmH2O Trigger Pressure: -20~20cmH2O
Monitoring parameters: O2 concentration, MV, Respiratory frequency, Tidal volume, Ppeak, PEEP, I:E ratio, Pmean, Compliance etc..
Alarm parameters:
high pressure alarm, low pressure alarm, O2 concentration alarm, MV alarm, O2 source failure alarm, AC power failure alarm, etc.
Pressure alarm setting:
High pressure alarm set 1~60cmH2O.
Low pressure alarm set 0~20cmH2O
O2 concentration alarm setting:
high: 21~99%.
Low: 21~50%.
MV alarm setting:
MV high alarm set 10~99L/min
MV low alarm set 0~40L/min

Main Unit:
Circle absorber: Compact circle absorber

Flow meter:
Five~tube flow meter O2 tube: 0L/min~1L/min~10L/min.
N2O tube: 0L/min~1L/min~10L/min.
Air tube: 0L/min~10L/min
O2 and N2O Linkage Device, keep oxygen concentration not lower than 25%
Oxygen flush: 25L/min~75L/min

Gas source pressure:
O2: 0.25Mpa~0.65MPa
N2O: 0.25Mpa~0.65MPa
Air: 0.25Mpa~0.65MPa
Gauge: 4 units, 2¡ÁO2£¬N2O, Air.
Dec-07-11
 
Special Feature:

Application: Adult, Pediatric
Driven mode: Pneumatically driven electronically controlled
Mode: Semi-open, Semi-closed or closed system
Anesthetic vaporizer: One vaporizer

Anesthesia Ventilator:
Display: High light LED display
Ventilation mode: IPPV and Manual mode
Tidal Volume: 50 ~ 1600ml
Breath frequency: 1 ~ 90BPM
I:E ratio: 4:1 ~ 1:6
Monitor parameter: Tidal volume, breath frequency, MV, Airway pressure
Alarm: MV high alarm, MV low alarm, TV high alarm, TV low alarm

Main Unit:
Circle absorber: Compact circle absorber
Bellow: 50 ~ 1600ml
Oxygen FLUSH: 25L/min ~ 75L/min
Flow meter:
O2, N2O two-tube flowmeter
O2 tube: 0L/min ~ 10L/min
N2O tube: 0L/min ~ 10L/min
O2 and N2O linkage device
Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% )
Gas source pressure:
O2: 0.25 ~ 0.65Mpa
N2O: 0.25~ 0.65Mpa
Gauge: 2 units, one N2O, one O2.
Apr-16-19
Supplier From United States, United States
May-19-14
Supplier From New Delhi, Delhi, India
Mar-09-18
Supplier From Zhengzhou, Henan, China
Oct-31-07
Supplier From Delhi, India
Jun-17-20
Supplier From Singapore
May-25-09
Buyer From Ankara, Turkey
Mar-13-18
Supplier From Zhengzhou, Henan, China

Verification Status