ARIES 2500 Anesthesia Machine: Display: 10.4 TFT color screen Application: Adult, Pediatric Driven mode: Pneumatically driven electronically controlled Mode: Semi~open, Semi~closed or closed system Anesthetic vaporizer: two high precise vaporizers Power supply: 220V,10%, 50Hz,1Hz 10V,10%, 60Hz,1Hz Internal battery: DC12V (4 working hours) Fresh gas outlet is in front of frame Anesthesia Ventilator: Respiration mode: IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY, DEMO Waveform: P-t, F-t, V-t, F-v, V-p Tidal Volume: 20~1600ml Respiratory frequency: 1~65bpm I:E ratio: 4:1~1:4 Inspiration pause: 0~55%Ti Inspiration Pressure: 1~60cmH2O Trigger Pressure: -20~20cmH2O Monitoring parameters: O2 concentration, MV, Respiratory frequency, Tidal volume, Ppeak, PEEP, I:E ratio, Pmean, Compliance etc.. Alarm parameters: high pressure alarm, low pressure alarm, O2 concentration alarm, MV alarm, O2 source failure alarm, AC power failure alarm, etc. Pressure alarm setting: High pressure alarm set 1~60cmH2O. Low pressure alarm set 0~20cmH2O O2 concentration alarm setting: high: 21~99%. Low: 21~50%. MV alarm setting: MV high alarm set 10~99L/min MV low alarm set 0~40L/min Main Unit: Circle absorber: Compact circle absorber Flow meter: Five~tube flow meter O2 tube: 0L/min~1L/min~10L/min. N2O tube: 0L/min~1L/min~10L/min. Air tube: 0L/min~10L/min O2 and N2O Linkage Device, keep oxygen concentration not lower than 25% Oxygen flush: 25L/min~75L/min Gas source pressure: O2: 0.25Mpa~0.65MPa N2O: 0.25Mpa~0.65MPa Air: 0.25Mpa~0.65MPa Gauge: 4 units, 2¡ÁO2£¬N2O, Air.
Special Feature: Application: Adult, Pediatric Driven mode: Pneumatically driven electronically controlled Mode: Semi-open, Semi-closed or closed system Anesthetic vaporizer: One vaporizer Anesthesia Ventilator: Display: High light LED display Ventilation mode: IPPV and Manual mode Tidal Volume: 50 ~ 1600ml Breath frequency: 1 ~ 90BPM I:E ratio: 4:1 ~ 1:6 Monitor parameter: Tidal volume, breath frequency, MV, Airway pressure Alarm: MV high alarm, MV low alarm, TV high alarm, TV low alarm Main Unit: Circle absorber: Compact circle absorber Bellow: 50 ~ 1600ml Oxygen FLUSH: 25L/min ~ 75L/min Flow meter: O2, N2O two-tube flowmeter O2 tube: 0L/min ~ 10L/min N2O tube: 0L/min ~ 10L/min O2 and N2O linkage device Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% ) Gas source pressure: O2: 0.25 ~ 0.65Mpa N2O: 0.25~ 0.65Mpa Gauge: 2 units, one N2O, one O2.
Supplier: Anesthesia equipment
Supplier: Surgical, critical care, anesthesia equipments and consumables, second hand equipments
Supplier: Medical equipment, anesthesia
Services: Transportation
Supplier: Orthopedic instrument, general instrument, disposal product, hospital furniture, anesthesia equipment
Supplier: Used-medical-equipment like-anesthesia-machine
Supplier: Medical equipments, cardiac, anesthesia machines, infant incubators, sterlizing containers.
Buyer: Medical & dental equipments, instruments, materials.
Supplier: Medical equipment, anesthesia machine, medical ventilator, patient fetal monitor