10hp air-cooled small power diesel engine Feature 1.Singe-cyliner, 4 stroke, air-cooled diesel engine 2.Direct injection combustion system 3.Efficient air cleaner system 4.Low fuel consumption , low emission 5.Multi-choice pto shafts are available The main parameter: Model gf186fa(e) Engine type single-cylinder, 4-stroke, air-cooled, ohv diesel engine Combustion direct injection Bore*stroke(mm) 86*72 Displacement capacity(cc) 208 Max.Output(hp)/rpm 10/3600 Fuel consumption(g/kwh) 210 Lubrication oil sae 10w/30 Lubrication oil volume(l) 1.65 Cooling system forced-air Starting system recoil/electric starter Governor system all-speed type, mechanial governor Fuel tank capacity(l) 5.4 Noise level at 7m(db) 96 Gross weight(kg) 50/55 Dimension(mm) 525*480*562 Per 20'gp cnt 192 Per 40'gp cnt 400 Faq Q: what is you leading time ? A:25-30 days in our normal season. Q:is it all right to make customer brand name? A: that is all right to make your own brand name. Q: where is your loading port? A:fuzhou, china port. Q: what are your payment term? A: 30% deposit and balance t/t against by the copy of b/l or l/c at sight. Q: what is you company available production capacity ? A: our company had a daily production capacity of one or three container. Meanwhile, we will has to work increase production capacity in the future Gross.Weight:50kgs Dimension: 525*480*562mm
Air cooled diesel engine from 19 hp to 188 hp/1500 rpm
Wholesale Yanmar clone China-made small diesel engine parts, power range from 3HP to 12HP. Parts for single cylinder,vertical ,4-stroke air cooled diesel engine,model 170F,173F, 178F, 186F,188F,192F Parts for 211CC,247CC,296CC,418CC,456CC,499CC air cooled diesel engine OEM genuine quality diesel engine parts Widely used in the Water pump, Generator set, Farm tiller, Construction Machinery, Agriculture Machinery, and Vehicles, etc.
We provide a large assortment of high utility small diesel engine that is procured from our well reckoned companies. Our diesel engine is manufactured from the optimum quality raw materials to add durability. Providing long lasting excellent performance, our small diesel engine is easy to handle and operate. We offer wide range of various types of water cooled, air cooled, single cylinder, double cylinder, taper roller bearing type, brass bush type diesel engine range form 3.5 h.P. To 25 h.P. Which is suitable and applicable for agricultural, industries, irrigation, workshop, generator set, flour mill, construction machinery, marin purpose etc. We provide following types of diesel engines High speed single cylinder water cooled diesel engine High speed single cylinder air cooled diesel engine High speed double cylinder water cooled diesel engine High speed double cylinder air cooled diesel engine Slow speed single cylinder water cooled diesel engine Slow speed double cylinder water cooled diesel engine Wooden box packed
EAP 220 Engine: Engine Model : 1106A-70TAG4 Stand By kVA: 220 Stand By kW : 176 Prime kVA: 200 Prime kW : 160 Rated Current : 288 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1106A-70TAG4 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 16:01 Bore 105 Strok 135 Displacement Lt 7,01 Air Intake Turbocharged and air charge cooled Speed (RPM) 1500 Oil Capacity Lt 18 Standby Power kw / Hp 196.3 / 265 Prime Power Hp 178.9 / 242 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 22 Fuel Consumption (lt / h) Lt Full Load 45,8 Lt %75 LOAD 34,7 Lt %50 LOAD 23,1 Frequency Hz Power kVA 200 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 DIMENSIONS Weight (Silent) Kg 2270 Weight (Open) Kg 1940 Width (Silent) Mm 1200 Length (Silent) Mm 3500 Height (Silent) Mm 1850 Fuel Tank Capacity Lt 360 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 200 Engine Model : 1106A-70TAG3 Stand By kVA: 200 Stand By kW : 160 Prime kVA: 182 Prime kW : 145 Rated Current : 262 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat IP 21-23 Protection Standard H Insulation Class 50 Hz Frequency 4 pole brushless synchronous type alternator Automatic Voltage Regulator (AVR) 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis Convenient design for easy lifting and carrying High standard sound proof canopy design Modular design with easily removable nuts - bolts Lockable doors Transparent window for watching Control Panel Electrostatic powder painted, providing protection against harsh weather conditions Emergency STOP button Fuel tank inside the chassis Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Model 1106A-70TAG3 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 16:01 Bore 105 Strok 135 Displacement Lt 7,01 Air Intake Turbocharged and air charge cooled Speed (RPM) 1500 Oil Capacity Lt 16,5 Standby Power kw / Hp 180.2 / 243,5 Prime Power Hp 162.7 / 220 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 22 Fuel Consumption (lt / h) Lt Full Load 41,5 Lt %75 LOAD 31,8 Lt %50 LOAD 20,2 Frequency Hz Power kVA 200 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 2190 Weight (Open) Kg 1850 Width (Silent) Mm 1200 Length (Silent) Mm 3500 Height (Silent) Mm 1850 Fuel Tank Capacity Lt 360 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.