Collector: 47-1500, 58-1800, 70-2000 the new unit triplet gradation membrane collector vacuum tube is efficient in heat absorption and temperature rising. Inner tank material: sus304-2b imported food-grade stainless steel. Outer covering material: imported high-quality aluminum-zinc coated steel plate and imported fluorine carbon plate. Heat insulating layer: 50-65mm polyurethane integral pressure foaming. Bracket material: high-quality aluminum-zinc coated and plastic-sprayed bracket, all kinds of color is available, the design is more reasonable, the color is more beautiful, it can be fixed flatly or scantly. 50kg per piece
Solar Safety Items Solar Traffic Blinkers, Solar Cameras, and Solar Rope Lights : We deal with Cost Effective, Reliable Solar Traffic Blinkers with extended backup capacities We do SITC of all types of Solar Cameras (PTZ , ANPR etc..) We do SITC of Solar systems for SOS on highways and Expressways We supply Solar Cat Eyes, Mini Solar Blinkers We also supply Solar Rope Lights for lighting safety barricading boards on construction sites like in Metro Projects.
TUF Marine Anti-glare solar screen blind is produced with high-performance composite film and materials. Therefore they can reduce most sun glare and harmful UV radiation with improved visibility and provide lasting service on ships/boats/offshore platforms. TUF Marine anti-glare solar screen is available with self locking type and electric control type. The produced screens will be packed in pallet which is safe and suitable for air or sea transport.
Supplier: Solar projects in patiala
The heat collectors and the water tanks are connected perfectly, the heat which the panels collected will be stored in the water tank, it guarantees 24 hours per day to provide the hot water, and the system can work even under the -30 degrees. It can supply with a few tons even more water, is an ideal hot water supply system. It is applied to the big hotels, restaurants and other large places. 1: The water tank should be placed higher than the heat collectors, while the models are isolated types and the heat collectors are not pressure-enduring; The water recycled freely by the height difference between the water tank and the heat collectors. 2: The water tank should be placed lower than the heat collectors, while the models are isolated types and the heat collectors are pressure-enduring, the water is recycled by the water pump between the water tank and the heat collectors, the specific pressure-enduring models, please see the information of the pressure-enduring models on the web.
KE47S Vacuum tube: 47x1500mm Inner tank: Stainless Steel 304 2B food grade Outer tank: Stainless Steel 304 BA Outer tank dia.420mm Frame: Stainless Steel Insulation: 50mm polyurethane total forming with pressure and high density Available sizes: 18, 20, 22, 24, 28, 30, 36 tubes with tank capacity 117L up to 230L
1.To support the solar panels 2.Various specifications 3.Quality guarantee 4.Fast deliver Size:0.04*0.06*l(up to your project) Weight:1.1kg/m
1.All Glass Vacuated Tube All glass evacuated tubes are the key component of solar collectors. The evacuated tube is similar to a conventional Dewar flask and consists of two borosilicate glass tubes, a glass with high chemical and thermal shock resistance. The outer side of the inner tube is coated with a sputtered solar selective surface. This coated inner tube is closed at one end and sealed at the other end to the outer tube. The annular space between the outer tube and inner tube is evacuated to virtually eliminate heat loss by conduction and convection. We use the tubes which use the successfully developed innovative Advanced Solar Selective Coatings in commercial scale, which achieve the highest thermal efficiency and good thermal stability. Solar selective coatings absorb most solar radiation while simultaneously suppressing the thermal emittance loss from coating surfaces. They vary mainly in their optical property and thermal stability. Excellent results have been obtained by using DC magnetron sputtering technology. A solar absorbance of 0.94 - 0.96 with an emittance of 0.04 - 0.06 at 100 centigrade has been achieved. Models º¦47í-150 º¦58í-180 Weight 1.35í+0.12kg 2.29í+0.18kg Structure All glass coaxial double-layer tubes All glass coaxial double-layer tubes Outer tube diameter º¦47í+0.7mm º¦58í+0.7mm Inner tube diameter º¦37í+0.7mm º¦47í+0.7mm Outer Tube thickness 1.6í+0.15mm 1.8í+0.15mm Inner tube thickness 1.6í+0.15mm 1.6í+0.15mm Tubes length 1542í+4mm 1812í+4mm Material of coating AlN/AIN-SS/Cu AlN/AIN-SS/CU Absorptance 0.94~0.96 0.94~0.96 Emittance 0.04~0.06 0.04~0.06 Vacuum Pí_5í-10-3pa Pí_5í-10-3pa Transmittance of Outer Tube 0.91 0.91 Stagnation temperature (height) 270~300íµ 270~300íµ Heat-loss coefficient í_0.6w/ m2*íµ) í_0.6 w/ (m2*íµ). Bearing hailstone ability hailstone diameterº¦25mm hailstone diameterº¦25mm. Pressure-endure ability 1MPa 1MPa.
Supplier: Electronic control panel, machinery, turnkey projects, automation projects
Services:
Buyer: