The FK-5-1-12 Clean Agents, also known as NOVEC1230 Fire Suppression Agents, is a highly efficient and reliable hydro-fluorocarbon fire extinguishing solution. This product is designed to quickly and effectively suppress fires in various settings while being non-toxic, environmentally friendly, and safe to use. Model Number: FK-5-1-12 clean agents Product Name: NOVEC1230 Fire Suppression Agents Reliability: High Model NO.: FK-5-1-12 clean agents Application The FK-5-1-12 Clean Agents is suitable for use in various applications, including but not limited to: Commercial buildings Industrial facilities Data centers Telecommunication rooms Museums and art galleries Power generation plants Server rooms Control rooms Storage facilities
The Notifier NBG-12 Series Pull Station is a fire alarm initiation device that allows manual activation of the fire alarm system. It typically consists of a red or yellow manual-pull handle or lever, which when activated, sends a signal to the fire alarm control panel to initiate an alarm. The NBG-12 series is designed for use in fire alarm systems and is commonly used in commercial, industrial, and residential buildings. The product is known for its durability and reliability, and it meets industry standards for fire alarm systems.
Intelligent fire Detection system as a high efficiency and low cost unmanned fire detection system in capable of an early detection regardless spontaneously fire or firebug. This system is located in outdoor area such small and middle sized cultureal assets, natural monument and outdoor facilities.
DESCRIPTION Type: PP24C Service Pressure: 0.5-1.0MPa Max Service Pressure: 1.0mpa Spray Capacity: mixed liquids 24l/s, water24l/s Range: more than 40m Horizontal rotary: more than +- 180degrees Max angle of elevation: more than +- 70 degrees Max angle of depression: less than -60degrees Allowable error of discharge capacity: +- 8% Foaming times(at 20degree): more than 6 25% discharge time(at 20 degree): more than 2.5min Effluent capacity: 85T/H Connection Flang: DN80
DESCRIPTION Introductions: 1.firefighting equipment Approval:ABS,CCS,BV,DNVetc 2.fire fighting equipment material :stainless steel 3.Capacity of fire monitor/fire pump : 160m3/h,180m3/h ,360m3/h ,600m3/h , 900m3/h , 1200m3/h , 3600m3/h ,etc 4.firefighting equipment Type:Supply external Fire Fighting Systems , FiFi1/4,FiFi1/2, FiFi 1, FiFi 2 , etc 5.Fire Fighting System Engine:Cummins Engine or the demands you need 6.Fire fighting equipment Include:fire pump,fire monitor,with diesel Engine 7.Firefighting equipment color:red Technical Parameters for Maritime Fire Fighting Fifi 3/ Firefighting 1 And 2 Firefighting Class System. 1.FiFi Class 2 System 7200m3/h Diesel Engine Driven Fire Pumps: 2X3600m3/h Fire Monitors:4X1800m3/h@150m, Remote Control System 2.FiFi Class 1 System 2400m3/h Diesel Engine Drivenor Electric Motor Driven Fire Pumps: 2X1200m3/h or one 2400m3/h Fire Monitors:2X1200m3/h@120m Remote Control System 3..FiFi 1/2 System Diesel Engine Driven or Electric Motor Driven Fire pumps: 1200m3/h Fire Monitors:2X600m3/h@120m or1X1200m3/h@120m Remote Control System 4.None Classed Fi-Fi System Diesel Engine Drivenor Electric Motor Driven Fire pumps:2X300m3/h@145m Fire Monitors:2X300m3/h@85m 5. None Classed Fi-Fi System 6.Fire Pump Unit, fire pumpCapacity: 4200m3/h,3600 m3/h, 2400 m 3/h, 1800 m3/h, 1200 m3/h, 600 m3/h, 300 m3/h,250 m3/h ,ect Certificate: CCS BV ABS DNV and other Class 7. Fire monitor Including fire water monitor , foam monitor , powder monitor with Electric/hydraulic romote control and hand whell REMARK:Designated the best solution for you,according to your requirements. Above just for your guidence. If you need this products For ship,pls provide the below information for external Fire Fighting Systems 1. Capacity of the Fire monitor for this Fire Fighting Systems (m3/h) 2. Fire pump Capacity for Fire Fighting Systems(m3/h) 3.Need the diesel Engine for fire pump 4.Any special brand demands for diesel fire pump engine Related pictures Maritime Fire Fighting Fifi 3/ Firefighting 1 And 2fir Firefighting Class System(fire monitor,fire pump,diesel engine for firefighting equipment)
A fire alarm system is a set of electric/electronic devices/equipment working together to detect and alert people through visual and audio appliances when smoke/fire is present. These alarms may be activated from smoke detectors, heat detectors, water flow sensors, which are automatic or from a manual fire alarm pull station. Types of Fire Alarm System: All Fire Alarm Systems essentially operate on the same principle. If a detector detects smoke or heat or someone operates a break glass unit (manual break point), then alarm sounders operate to warn others in the building that there may be a fire and to evacuate. It may also incorporate remote signaling equipment which would alert the fire brigade via a central station. Conventional Fire Alarm System In a Conventional Fire Alarm System, a number of call points and detectors are wired to the Fire Alarm Control Panel in Zones. A Zone is a circuit and typically one would wire a circuit per floor or fire compartment. The Fire Alarm Control Panel has a number of Zone Lamps. The reason for having Zones is to give a rough idea as to where a fire has occurred. This is important for the fire brigade and of course for the building management. The accuracy of knowing where a fire has started is controlled by the number of Zones a Control Panel has and the number of circuits that have been wired within the building. The Control Panel is wired to a minimum of two sounder circuits which could contain bells, electronic sounders or other audible devices. Each circuit has an end of line device which is used for monitoring purposes. Addressable Fire Alarm System The detection principle of an Addressable System (Fire Alarm System) is similar to a Conventional System except that the Control Panel can determine exactly which detector or call point has initiated the alarm. The detection circuit is wired as a loop and multi devices may be connected to each loop. The detectors are essentially Conventional Detectors, with an address built in. The address in each detector is set by dil switches and the Control Panel is programmed to display the information required when that particular detector is operated. Additional Field Devices are available which may be wired to the loop for detection only i.e. it is possible to detect a normally open contact closing such as sprinkler flow switch, or a normally closed contact opening. Fire Alarm System comes with single loop as well as multi loops. It depends on requirement. The items which are integrated with Fire Alarm Systems are given belowâ?¦. Brands are available : AGNI, MORLEY, NOTIFIER, Modern Technologies gives you top class branded Fire Alarm System with affordable price. We also provide installation & maintenance services.
Product Description: We are working with highly experienced packaging experts and they make every endeavor to meet the personalized and standard requirements of the clients. We sternly make our product safe from external factors. We, being a customer centric organization, make sure that the transactions are carried out by the professionals so as to avoid any kind of confusion. We sternly maintain payment records for the satisfaction of our clients.