Supplier : Power transformer, switch gear, oil immersed transformer

Services : Export
Established: 2008 Standards: CE

Verification Status



Contact Details:
No.6, Shuige Road, Jiangning District,nanjing, China
- 211153
Jiangsu China


Recent User Reviews

This user has not received any reviews yet!
 
 
Contact Supplier
Renew

More Items Similiar to: Nantong Rongheng Environmental Equipment Co., Ltd.

GOLD Member
Mar-01-24

Transformers

$20
MOQ: Not Specified
Supplier From Ludhiana, Punjab, India
 
Transformers,Distribution and Power Transformer,Varivolt
Safety Transformers
Diesel Generators
Industrial Panels
Stabilizers
Energy Saver
Industrial Panels
GOLD Member
VERIFIED
Nov-01-07
Supplier From Gresik, East Java, Indonesia
Jun-18-18
 
Execution standard
GB 1094.1-2 power transformer general rules, power transformer temperature rise
GB 1094.3 power transformer insulation level and insulation test
GB 1094.5 "power transformer capacity to withstand short circuit"
GB/T 6451 technical parameters and requirements of three-phase oil-immersed power transformer
GB/T 15164 load guide for oil-immersed power transformer
IEC76 power transformer
GB 2536 "transformer oil"
800KVA~31500KVA three-phase double-winding non-excitation voltage regulating power transformer:
Jun-18-18
 
Performance parameters of S13 type 10kV double winding series:
Type rated capacity (KVA) connection group label voltage combination (KV) no-load loss (W) load loss no-load current (%) short circuit resistance (%)
High pressure range low Dy Yy.
10 10 Yyn0 / S13 - M -
or
Dyn11 10
6.3
6 + / - 5%
Plus or minus 2 x 2.5%
or
+ 3 x 2.5%
-1 x 2.5% 0.4 40 360 340 2.8 4.0.
S13-M-20, 70, 525, 500, 2.5.
S13-M-30, 30, 80, 630, 600, 2.3.
S13-m-5050 100 910 870 2.0.
S13-m-63, 110, 1040, 1040, 1.9.
S13-m-80 130 1310 1250 1.9.
S13-m-100, 100, 150, 1580, 1580, 1580.
S13-M-125, 125, 170, 1890, 1800, 1.7.
S13-m-160, 200, 2310, 2200 1.6.
S13-M-200, 240, 2730 2600 1.5.
S13-m-250, 250, 290, 3,050, 1.4.
S13-m-315 315340 3830 3650 1.4.
S13-m-400, 4410, 452043001.3.
S13-m-500, 480, 5410, 5150, 5150.
S13-M-630 630 570 6200 6200 1.1.
S13-m-800, 700, 7500, 7500, 1.0.
S13-m-1000, 830, 10300 10300 1.0.
S13-m-1250, 1250, 970, 12000, 0.9.
S13-m-1600 1,170 14500 14500 0.8.
S13-m-2000, 1510, 17800, 17800.0.8, 5.0.
S13-M-2500, 1780 20700 20700 0.7.
S13-m-3150 3150 2100 24300 24300 0.7.
GOLD Member
Mar-27-18
Supplier From Bengaluru, Karnataka, India
Jun-18-18
 
Dry type transformers shall be installed in accordance with the manufacturer's requirements, and shall be equipped with temperature measuring devices, generally 630kVA and above transformers.
A,1000kVA and above oil-immersed transformer shall be equipped with an outdoor signal thermometer and can take distant signals.
Product features:
A, tank using corrugated sheet, it has the respiratory function to compensate for temperature change caused by the oil volume change, so the product without oil storage tank, obviously reduce the height of the transformer.

B, because the corrugated film replaces the storage tank, the transformer oil is isolated from the outside, thus effectively preventing the entry of oxygen and water and the decrease of insulation performance.

C, according to the above five performance, to ensure the oil-immersed transformer within the normal operation of the don't need an oil change, greatly reduces the maintenance cost of transformer, and prolong the service life of the transformer.
D. In addition to the small capacity of copper wire, copper foil is usually used in the cylinder structure.
The high voltage winding adopts multi-layer cylindrical structure to balance the ampere-turns distribution of the winding, the leakage is small, the mechanical strength is high, and the anti-short circuit capability is strong.

E, iron core and winding each adopt the fastening measure, the height of the device, the low voltage lead wire and other fastening parts are equipped with self-locking anti-loose nuts, adopt the non-lifting structure, can withstand the shock of transportation.

F, coil and iron core adopt vacuum drying, the transformer oil adopts vacuum filter oil and oil filling process, which minimizes the moisture in the transformer.
Jun-18-18
 
Product features
1. The transformer core is made of imported high quality cold rolled silicon steel, which greatly reduces the no-load loss and no-load current, and the core is bound to ensure the tightness of the core and reduce the noise.
2. The high and low voltage winding is made of anaerobic copper, and the low-voltage winding 500kVA and the following are double-layered cylindrical structures.
A double helix or four-helix structure is used in 630kVA and above. Multi-layer cylindrical structures are used for high voltage windings.
3. The transformer connection group adopts Dyn11 to reduce the influence of harmonics on the power grid and improve the quality of power supply.
4. The transformer is full seal structure, extending service life, free of hanging core and maintenance.
5. The measured noise is below the standard.
After normal transportation, the series of transformers can be installed with relevant parts, and the test of acceptance test can be put into operation.
Jun-18-18
 
Dry type transformers shall be installed in accordance with the manufacturer's requirements, and shall be equipped with temperature measuring devices, generally 630kVA and above transformers.
A,1000kVA and above oil-immersed transformer shall be equipped with an outdoor signal thermometer and can take distant signals.
Product features:
A, tank using corrugated sheet, it has the respiratory function to compensate for temperature change caused by the oil volume change, so the product without oil storage tank, obviously reduce the height of the transformer.

B, because the corrugated film replaces the storage tank, the transformer oil is isolated from the outside, thus effectively preventing the entry of oxygen and water and the decrease of insulation performance.

C, according to the above five performance, to ensure the oil-immersed transformer within the normal operation of the don't need an oil change, greatly reduces the maintenance cost of transformer, and prolong the service life of the transformer.
D. In addition to the small capacity of copper wire, copper foil is usually used in the cylinder structure.
The high voltage winding adopts multi-layer cylindrical structure to balance the ampere-turns distribution of the winding, the leakage is small, the mechanical strength is high, and the anti-short circuit capability is strong.

E, iron core and winding each adopt the fastening measure, the height of the device, the low voltage lead wire and other fastening parts are equipped with self-locking anti-loose nuts, adopt the non-lifting structure, can withstand the shock of transportation.

F, coil and iron core adopt vacuum drying, the transformer oil adopts vacuum filter oil and oil filling process, which minimizes the moisture in the transformer.
Jun-01-18
 
Our oil-immersed power transformers have stable operation, high safety and efficiency, low price and wide application. Oil-immersed power transformers are integrated with production, sales and installation, with strong strength and good reputation.

Our oil-immersed power transformers have stable operation, high safety and efficiency, low price and wide application. Oil-immersed power transformers are integrated with production, sales and installation, with strong strength and good
Jun-23-22

Oil Immersed Transformer 500Kva

$8.00K
MOQ: Not Specified
Supplier From Ha Noi, Alabama, Viet Nam
 
Product specifications
Rated power: 2500kVA
Voltage: 22/0,4kV
Winding connection: Dyn11
No-load loss (Po): 1850 W
Short-circuit loss(Pk): 21000 W
Max. no-load current(I0): 1.5%
Short circuit voltage(Uk ): 6%
Standard: : TCVN 6306 (IEC 60076); Decision 62 / Q EVN (Vietnam), ISO 9001:2015; ISO 14001:2015 (International).

Verification Status