Overview High voltage insulation megohmmeter is composed of medium and large scale integrated circuits. This meter has large output power high short-circuit current value and large output voltage grades (there are four voltage grades). The working principle is as follows: the DC high voltage generated by the battery inside the machine as power supply and converted by DC/DC reaches the L pole from the E pole by the tested product so as to generate a current from E to L pole. After I/V conversion and operation by the divider the measured insulation resistance value is directly displayed by LCD. Technical Parameters Working Conditions environment temperature relative humidity 85%RH output voltage level 500V 1000V 2000V2500V measurement range 019990M Resolution 0.01M0.1M1.0M10.0M relative error Voltage/load 2500V/20M Voltage drop about10% short-circuit current 1.6mA direct current 81.5V(AAR6)battery alternating current 220V/50Hz Power quiescent dissipation
GF312V2 portable three phase multifunction watt-hour meter calibrator on-site is the newest product produced by our company by widely visiting users and referring to the advantages of the same kind of products home and abroad. The measured part of the product adopts high speed A/D transmission to send DSP to conduct digital processing, which largely improves measured degree of accuracy and stability. Central processing part adopts 32-bit ARM embedded technology to make instrument interface novel, function abundant, operation distinct and easy, and performance steady. Class of accuracy: Class 0.02, 0.05 or 0.1, range from 12A/600V or 120A/600V, with comfort design, small size and light weight. The model GF312V2 watt-hour meter calibrator is suit for electric power departments, measuring and quality examining departments and electric lab to field use.
Product Overview The ignition point of a fire inside the electric panel is mostly the part where the terminal block is fastened, so in order for initial fire extinguishing, the solution should be closely installed to the part where the terminal block is fastened. In the case of a small electric panel, a complete initial fire extinguishing is expected for fires occurring inside the electric panel by attaching the SFEX Pad to the top surface of the electric panel. Product Feature It has an excellent performance in the initial fire suppression as it can be installed near the ignition point as a flexible rope type. It uses a stand-alone method based on polymer chemistry so that it does not cause malfunctions and maintenance costs. The thermo-responsive Granule composed of KNO3 and subsidiary catalysts It does not affect the peripherals after the fire goes out. Function of SFEX Granule = fire extinguishing agent storage tank + temperature sensor + nozzle function Fire extinguishing method : Suffocation + subsidiary catalyst Example of Installation 1 : SFEX Line - If ducts exist Installing the SFEX Line horizontally or vertically in the ducts closest to the expected ignition points It can be installed without damaging the panel Example of Installation 2 : SFEX Line - If ducts do not exist Installing the SFEX Line horizontally or vertically, close to the expected ignition points of the Electric panel Example of Installation 2 : SFEX Pad - Small Electric Panel Simply attach it to the top inside the Electric panel.
Electric designs, manufactures and supplies OHL hardware and accessories for power transmission and distribution lines with over 20 years experrience. Single insulator tension & suspension string Double insulator tension & suspension string Triple insulator tension & suspension string STANDARD Electric comply with the standard of IEC61284, BS729, BS3288, ISO1461, IEC60120. PRODUCT RANGE 11kV-500kV insulator strings. All the components of insulators strings can be found in the catalogs. Electric can also make the design according to client's reuirements. APPLICATION The tension, suspension and jumper strings are used for OHL transmission lines with porcelain insulators, glass insulators or composite insulators.
"This comprehensive Radiator Mounting Kit provides everything you need to securely install panel radiators onto walls, adapting to the specific requirements of each region and country. Contents: Bleed Valve Plug: We offer a variety of bleed valve plugs to match local standards and preferences. Blanking Plug: Choose from various sizes and materials to suit your needs. Assorted Screws: A selection of screws designed for different wall types and installation methods. Assorted Wall Plugs: Compatible wall plugs for secure anchoring in diverse wall materials. L-Bracket Clips: Durable and reliable clips for attaching the radiator to the brackets. Bleed Key: A sturdy bleed key for easy air venting. Benefits: Complete Solution: Provides all the essential components for a hassle-free installation. Customizable: Contents can be tailored to meet specific regional requirements and customer preferences. Secure and Stable Installation: Ensures your radiator is safely and securely mounted. Versatile: Suitable for a wide range of panel radiators. High-Quality Materials: Durable and long-lasting components for reliable performance. Contact us to discuss your specific requirements and create a customized Radiator Mounting Kit for your market! Become a Global Distributor FREE Partnership We are actively seeking distributors worldwide to partner with us. Contact us today to explore partnership opportunities and offer high-quality mounting kits to your customers!"
The GF302D1 three phase portable energy meter test equipment consists of an integrated three phase current source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display. Voltage & current harmonics output from 2 to 63 times. This model portable meter test equipment can be programmable by PC, automatic generation of energy meter error test report.