I product features Using unique pulse phase modulation method eliminate tubes acoustic oscillation to ensure the safety of tubes, prolong services life. Adopt unique pulse deduct technology to achieve overload protection. Its consumption is low, the efficiency is as high as 96%; the power factor above 0.99, low total harmonic current distortion, less impact on power network. Wide working voltage range: ac 90v~260v, which can guarantee the output power constant when the input power voltage is unstable. Perfect protection function, such as built-in overvoltage, undervoltage, output short circuit, open circuit, which can protect automatically for safe use. Low temperature rise, it is suitable for wide range environment temperature: -30? to +50?(-22~+122f) Ii technical parameters Lamp watts: 70w high pressure sodium lamp Input voltage frequency: 50/60hz Input voltage range: 160-260v ac Input current: 0.35a Power factor: >0.99 Total harmonic current distortion: =8% Short circuit protection yes Open circuit protection yes Overheating protection yes Lamp failure protection yes Temperature range : - 30 ? ~ + 50 ? Size (l * w* h) 148 x 77 x 51.2 mm Iii: standards and certification: Safety en61347-2-12 Emi en61000-3-2 Ems cisper15.Ed7.2 Quality standard iso9001 Environmental standards iso1400 Related certification ce/ccc
Supplier: Eletronic
Buyer: Eletronic
Supplier: Eletronics
Buyer: TV, DVD, VCD, VHS
Supplier: Eletronics
Supplier: Eletronics and appliances
Buyer: Roborock robot vacuums s8 s7 q7 e5
Dimmable electronic ballasts Fl 2x35/220-240v t5 dim-a Dimming range from 1-100% Lamp start at 1% possible Standard dc1-10v control interface (en60929 with earth leakage 0.5ma) Defined lamp friendly warm start within 1.5 s with ac and 0.6s with dc Dc operation in emergency lighting Installations to vde0108 Safe shutdown of defective lamps Safe shutdown of lamps at end of life Automatic restart after lamp replacement Operating frequency ~40-120khz Carton
I product features: Using unique pulse phase modulation method eliminate tubes acoustic oscillation To ensure the safety of tubes, prolong services life. Adopt unique pulse deduct technology to achieve overload protection. Its consumption is low, the efficiency is as high as 96%; the power factor above 0.99, Low total harmonic current distortion, less impact on power network. Wide working voltage range: ac 90v~260v, which can guarantee the output power constant When the input power voltage is unstable. Perfect protection function, such as built-in overvoltage, undervoltage, output short circuit, Open circuit, which can protect automatically for safe use. Low temperature rise, it is suitable for wide range environment temperature: -30? to +50?(-22~+122f) Ii technical parameters Lamp watts: 360w high pressure sodium lamp Voltage frequency: 50/60hz Input voltage range: 160-260v ac Power factor: >0.99 Wave crest ratio: =1.7 Short circuit yes Open circuit yes Over-temperature yes Lamp failure yes Temperature range : - 30 ? ~ + 50 ? Size (l * w* h) 197 x 106 x 63 mm Iii: standards and certification: Safety en61347-2-12 Emi en61000-3-2 Ems cisper15.Ed7.2 Quality standard iso9001 Environmental standards iso1400 Related certification ce/ccc
I product features Using unique pulse phase modulation method eliminate tubes acoustic oscillation to ensure the safety of tubes, prolong services life. Adopt unique pulse deduct technology to achieve overload protection. Its consumption is low, the efficiency is as high as 96%; the power factor above 0.99, low total harmonic current distortion, less impact on power network. Wide working voltage range: ac 90v~260v, which can guarantee the output power constant when the input power voltage is unstable. Perfect protection function, such as built-in overvoltage, undervoltage, output short circuit, open circuit, which can protect automatically for safe use. Low temperature rise, it is suitable for wide range environment temperature: -30? to +50?(-22~+122f) Ii technical parameters Lamp watts: 130w high pressure sodium lamp Input voltage frequency: 50/60hz Input voltage range: 160-260v ac Input current: 0.65a Power factor: >0.99 Total harmonic current distortion: =8% Short circuit protection yes Open circuit protection yes Overheating protection yes Lamp failure protection yes Temperature range : - 30 ? ~ + 50 ? Size (l * w* h) 148 x 77 x 51.2 mm Iii: standards and certification: Safety en61347-2-12 Emi en61000-3-2 Ems cisper15.Ed7.2 Quality standard iso9001 Environmental standards iso1400 Related certification ce/ccc
I product features Using unique pulse phase modulation method eliminate tubes acoustic oscillation to ensure the safety of tubes, prolong services life. Adopt unique pulse deduct technology to achieve overload protection. Its consumption is low, the efficiency is as high as 96%; the power factor above 0.99, low total harmonic current distortion, less impact on power network. Wide working voltage range: ac 90v~260v, which can guarantee the output power constant when the input power voltage is unstable. Perfect protection function, such as built-in overvoltage, undervoltage, output short circuit, open circuit, which can protect automatically for safe use. Low temperature rise, it is suitable for wide range environment temperature: -30? to +50?(-22~+122f) Ii technical parameters Lamp watts: 110w high pressure sodium lamp Input voltage frequency: 50/60hz Input voltage range: 160-260v ac Input current: 0.54a Power factor: >0.99 Total harmonic current distortion: =8% Short circuit protection yes Open circuit protection yes Overheating protection yes Lamp failure protection yes Temperature range : - 30 ? ~ + 50 ? Size (l * w* h) 148 x 77 x 51.2 mm Iii: standards and certification: Safety en61347-2-12 Emi en61000-3-2 Ems cisper15.Ed7.2 Quality standard iso9001 Environmental standards iso1400 Related certification ce/ccc