Introduce Temperature and Humidity Test Chamber is designed for testing the capability of heat-endurance, cold-endurance, dryness-endurance, and humidity-endurance, it is suitable for quality control of the industries of electron, electrical equipment, vehicle, metal, foodstuffs, chemistry, building materials, luggage, printing, packaging, etc. Featurers 1)The separation of humidifier circuit from electric circuit improves safety and protects the circuit against the leakage of water supply line. 2)Available in Chinese and English LCD touch screen, easy operation and program. 3)Able to display the relative date and information of the whole operating system in running mode, graphic display. precautions, maintenance and troubleshooting appear on the screen instantly. 4)The Sirocco fan motor provides greater cyclic airflow to avoid dead corner in the chamber so as to obtain an uniform distribution of temperature and humidity. 5)The system of heating up, heating down, dehumidifying, and humidifying can be operated independently so as to reduce the cost of testing, extend the operating life of the machine and decrease the failure rate. 6)Water Supply adopts automatic watering System, Circulating water supply together with water filter.
ALTITUDE TEST CHAMBER Altitude test chambers combine temperature and altitude with optional humidity for simultaneous environment testing. Features External pressure type box body structure and stainless steel tank design, rational air circulation system and scientific layout of heating, refrigerating system. Adopts international brand of imported parts for cooling system to improve operation reliability High precision and stable performance with touch screen controller, friendly Man-Machine interface. Multiple layers of safety device to easy maintenance. Standards Implement and Met GB11159-89 GB10590-89 GB15091-89 GB/T2423.25-1992 GB/T2423.26-1992 GJB150.0-86 Specifications 1. Dedicatetouch and excellent user experience 2. Unique and compact design, top grade appearance, stable performance and easy operation 3. Can simulate a wide rang of temperature and humidity environments 4. Capable of testing large components, assemblies, and finished products 5. Customized sizes and configurations available 6. One year warranties
Optional accessories Cable port: two size of cable port is available: diameter: 50mm, diameter:100mm. Double door Pass room: provided to avoid disturbance of atmospheric temperature and humidity while opening the door. Floor reinforcement: can be fixed if heavy specimen placed in the chamber for test. Carry-in inclined platform: provided below the door to facilitate moving of specimens in and out through the door. normal running, a malfunction running or stand by occurs. Water purifier
Standard configuration Sight window*1, cable port(port diameter: 50mm)*1, shelves*2, chamber lamp*1, power cable *2m No fuse breaker, over pressure¡¢over heat and over current protection for compressor, Over temperature protection, over load protect of blower, dry heat protection A glass door can be provided behind the main door so that specimens can be observed. Two operation ports of 130mm diameter are used for handing specimens inside the chamber without opening the glass door. Dehumidifier The rotation regenerating dehumidifier m-120 ensures precise control of low humidity (5¨¬c 5%rh) for electrostatic reliability tests. Temperature and humidity recorder -100 to +150¨¬c/0 to 100%rh 100mm with effective width 100mm and 2 pen Temperature 1 pen and humidity 1 pen. -100 to +150¨¬c/0 to 100%rh 100mm with effective width 100mm and 6 dots Temperature 3 dots and humidity 1 dot. -100 to +150¨¬c/0 to 100%rh 100mm with effective width 180mm and 12 dots Temperature 6 dots and humidity 6 dots.
1. The test angle is based on national standards gb4706.1-2005 (iec60335-1: 2004) chapter 11, " fever " in the design and manufacture of test requirements. 2.The test angle is mainly used for a variety of electrical, temperature testing provides electrical products meet the standard requirements of environmental conditions temperature test. The actual test sample can be customized with different distribution specifications, test angle number and dimensions of the measurement points.
We have been in this line for many years, our products is very competitive and resonable . Wooden cases, 100kg, 620x460x1530
We are offering eut monitoring system that includes eut monitoring, analysis and data recording. These eut monitoring systems analyzes data during the test for interference or failure conditions, and records test data for retrieval after the test is complete. It is designed as a stand-alone system to communicate with the main test system using our eut monitoring and test software. The eut (equipment under test) monitoring system combines the following: Monitoring instrumentation Video and audio equipment Software to provide eut signal monitoring (analog and digital) Eut stimulation Monitoring for visual or audio interference during testing The monitoring is enabled only after the test level is established with the main test system, since the EUT Monitoring System is fully synchronized with test system. These are appreciated because all parameters captured by the EUT Monitoring System during testing ensures to accurately recreate interference or failure points to resolve compatibility issues monitored. These systems are configured specifically to cater the test needs and can be configured for specialized requirements such as audio breakthrough required by mobile radio standards and ABS/TCS testing needed in automotive test standards. Our entire range of standard as well as customized seamless interface with main test system completes the control of the EUT Monitoring System from the control room console. System Components: EUT stimulation and monitoring instruments selected to cover applicable specifications and meet your price/performance requirements Video monitoring system using shielded color cameras to visually monitor equipment under test An audio monitoring system can supply as a stand-alone solution or built into the video camera system A system controller with application software that offers power to control monitoring equipment These are used to process and store data, graphics, and results of series measurements System cabling and switching to connect the control room with the chamber Shielded room allow test engineers complete control of the EUT monitoring system from the desktop Fiber optic links for analog and digital signal monitoring. We are offering Radiated Conducted EMS that is used for EMS Testing Many electronic products. The subassemblies must meet immunity testing requirements depending on the product's target marketplace. These are designed specifically to meet the requirements of specific environmental use and internal manufacturer's requirements. It also needs an engineer to control instrumentation from a variety of vendors and perform detailed test procedures for numerous specifications. These are known for integrating test instrumentation, system controls, positioning devices, and software to perform automated, semi-automated, and manual immunity measurements in an anechoic chamber, shielded room, or test cell. The range of test specifications is carefully evaluated to develop an integrated test environment covering the basic, generic, product family and product specific standards. The entire recommendation is based on proven system installations, in-house research and development, and extensive experience with dozens of test instrument suppliers. It result in a seamless interface the test system and the test environment. We are offering a range of Radiated Conducted EMI that is designed and manufactured to use in an anechoic chamber, shielded room, OATS, or test cell to perform automated, semi-automated, and manual emissions measurements. These systems are integrated with test instrumentation, system controls, positioning devices and software. This helps to test specific products or subsystems for electromagnetic emissions according to international, R&D and manufacturer-specific standards. Designed especially to meet customerÆs requirements, these receive the exact system solution. This is offered without unnecessary components and costs associated with off-the-shelf, "one size fits all" test systems. Further, we also offer turnkey solution for our Radiated Conducted EMI, which includes system designing and installation with dozens of test instrument supplies. The turnkey EMI Test System designed by us assist to meet product testing requirements. A typical system includes: EMI test instrumentation selected to cover applicable frequencies and meet your price/performance requirements. Antennas/LISNs/Clamps selected to match both test standards and test facility capabilities. Measurement Accessories such as switching and positioning devices that simplify control and increase efficiency. An EMI Main Control Console with instruments and system controls strategically placed to provide test engineers easy access to all functions, and a comfortable, ergonomically-correct work environment. A System Controller with Application Software that offers state-of-the-art power to perform emissions tests from pre-scan to final measurements and to control multiple EMI analyzers and receivers. Proven Solutions: Our test system developments are based on the systems in Europe, North America, and Asia. Each new system incorporates the latest technologies instead of an off-the-shelf approach to design and to explicitly cover the standards. It provides accurate, repeatable measurements and minimizes demands on your limited resources. We are offering Observation System that is appreciated by the clients for conforming to various international quality standards. These are known as Specific Absorption Rate Test Systems (SRC), which include SAR Measurements, System Components, Measurement System, Probes & Measurement Accessories and Position Controller & Positioning Robot. The detail description of Specific Absorption Rate Test Systems is as follows: The SAR System: It is used to measure electromagnetic fields and calculated SAR over a customer-specified frequency range. All tests are conducted in a shielded test room. SAR Measurements: SAR testing works with the thermal effects of human exposure to RF electromagnetic fields. It corresponds to the relative amount of RF energy absorbed of a device close to the body. The test is conducted to verify that the RF energy emitted by a device is within permissible limits for public exposure as defined by test standards. The SAR Measurement System is comprised of the following subsystems: Measurement System: It is an easy to use, flexible package optimized for dosimetric evaluation of radio products. The whole package includes Data Acquisition Electronics and system control computer. Probes and Measurement Accessories: Various broadband probes and support accessories are available based on test requirements. It includes probes to measure current distribution on radio products in free space, to measure fields inside fluids simulating body tissue and to test radiated emissions from mobile radio equipment. Position Controller and Positioning Robot: The automated robot positions the probe inside the tissue-simulating liquid over a precisely defined volume. The robot is controlled by a multiprocessor positioning device. Air tieght packing with container, steel packing, wooden packing
Resistance Test Instrument Supplier ZY9733 and ZY9734 digital desk type low current resistance measuring meters are suitable for units concerned to measure the DC resistance of various components and parts with certain limitations on current, such as platinum resistor, coppery thermal resistor, PTC ceramics, thermistor and various wire rods, etc. 1. Key features 1.1 It adopts a large green LED to display measured value, which is striking and clear. It also adopts the four-terminal resistance measurement method to eliminate the impact of conductor resistance, and the measurement accuracy is high. 1.2 There are a variety of specifications, and each specification has four scales to meet the measurement requirements of different users. 1.3 The test current is lower than similar equipment, which effectively prevents the impact of components and parts on resistance. 1.4 ZY9734 type has a RS-232 serial data output interface to facilitate the connection to computer. 1.5 It adopts a novel plastic shell and can changes the inclined angle between the device and table by adjusting the handle position, so as to determine the suitable panel observation angle. It has a well-designed appearance and is easy to use. 2. Main technical indicators Temperature: Reference conditions: 20±5; nominal condition: 5~35 Relative humidity: Reference conditions: 40~60%; nominal condition: 25%~75% Power source: AC 220V±10%, 50Hz, power consumption: About 5VA.
Sandeep Garg & Company equipped with the latest XRF analyzers for accurate reading on any metal. Our XRF alloy analyzers are portable hand-held devices that follows stringent quality control norms to ensure the requisite quality of metal scraps as per the contractual standards.