4'' reverse osmosis membrane vessel for water treatment. Pressure:300, 450, 600, 800, 1000psi Color:white, blue, yellow
Nanovela Residential RO Membrane have two Series TW(tap water) Working TDS from 500~2000ppm,salt rejection 98%,recovery 25% BW(brackish water)----High TSD Working TDS from 2000~4000ppm,salt rejection 97% recovery 20% our RO membrane have more stable performance and longer life under high TDS feed water We have M.A.T.P(massive adaptive testing platform) Except 100% vacuum test,we also do random water test to make sure RO membrane good quality We are a Chinese RO membrane manufacturer expert!
Reverse Osmosi Membrane Benefits Reverse Osmosis Membranes Remove up to 99% Of Total Dissolved Solids. RO Membranes Remove Dissolved Impurities Such As Chloride, Lead, Chromate, Fluoride, Bacteria and Others. High Rejection TM700 Series Ultra Low Pressure TMH and TMG Series Low Fouling And High Tolerance TML Series High Rejection TM800 Series, for Sea Water Applications High Pressure & Rejection TM800H Series, for High Salinity Sea Water Applications
Permeated flow: 75GPD salt rejection: 97% test ppm:500 test temp.:25 recovery:15%
Model: TFC-2012-50 The reverse osmosis (RO) membrane sheet is imported from TORAY. Designed for reverse osmosis(RO) filters, reverse osmosis(RO) water purifier, reverse osmosis(RO) system. The pores of the reverse osmosis membrane(RO membrane) is only 0.0001 micron to release water molecules and eliminate organic and inorganic compounds, heavy metals, bacteria and viruses. Advantages: -Using international well-know company TORAYs reverse osmosis(RO) membrane sheet to ensure the quality of the reverse osmosis membrane(RO membrane). -Offering outstanding reverse osmosis(RO) membrane manufacturing technology to support a variety of reverse osmosis membrane(RO membrane) component OEM services. -Strong R&D staffs to offer customization service of reverse osmosis membrane(RO membrane) component. -Comprehensive advantages both at RO(reverse osmosis) membranes quality and price. -Supporting customer design in RO membrane (reverse osmosis membrane)size, reverse osmosis (RO) membrane label, etc. Specification: Minimum salt rejection:95% Permeate flow: 50 GPD Diameter: 2 inch Length: 12 inch Testing pressure : 65 psi Testing temperature: 25 ¡ãC PH value of testing solution: 6.5-7.5 Concentration of testing solution:500ppm Recovery rate of single membrane element: 10% Max feedwater temperature : 45 ¡ãC PH value range of feedwater: 4-11 Max NTU of feedwater: 1 Max SDI of feedwater: 5 Max concentration of free chlorine:0.1ppm.
Ro Flat Sheet, Reverse Osmosis membrane Model: U-HR, U-HF, U-XP Flow Rate(GFD):26~34,35~43,45~55 Rejection(%):99.5-98.5-95.0 Adapted Models: 1812.4021/2012,3012,3013/ LOW PRESSURE For more info, pls contact me.
UPT series ultra pure water purification system is designed for simple and intuitive. It produces Type I (UP ultrapure water) and Type II (pure water) directly from tap water. Water temperature and conductivity (resistivity) are monitored online. It is a cost-efficient laboratory equipment for ultrapure water production. RO pure and UP ultrapure water is available directly from tap water. (Conductivity of pure water ¡Ü Conductivity of raw water¡Á2%; Resistivity of UP water is 18.2 M¦¸.cm) Automatic flashing for the Reverse Osmosis membrane Resistivity online monitoring for UP ultrapure water Conductivity online monitoring for RO water for model UPT-¢ò 0.2¦Ìm micro filter equipped in the UPT.
KeenSen BW and FR Series: Brackish Water and Fouling Resistant RO Membrane Element Model No.:BW-8040/4040, BW-8040FR/4040FR(Fouling Resistant) Usage:It is applicable to the desalination of surface water, groundwater and water treatment with salt concentration between 2000 and 8000ppm. It can be widely used in the medicine, chemical industry, beverage, electricity and other various industries etc. Operating Limits and Conditions of Membrane Element Max. Working Pressure 600 psi(4.14MPa) Max. Feed Water Temperature 45 Max. Feed Water Flow 17.0m3/h(8040),3.6m3/h(4040) Max. Feed Water SDI15 5.0 Free Chlorine Concentration of Feed Water 0.1mg/L pH Range of Feed Water during Continuous Operation 3-10 pH Range of Feed Water during Chemical Cleaning 2-12 Max. Pressure Drop of Single Membrane Element 10psi(0.07Mpa)
KeenSen BW and FR Series: Brackish Water and Fouling Resistant RO Membrane Element Model No.:BW-8040/4040, BW-8040FR/4040FR(Fouling Resistant) Usage:It is applicable to the desalination of surface water, groundwater and water treatment with salt concentration between 2000 and 8000ppm. It can be widely used in the medicine, chemical industry, beverage, electricity and other various industries etc. Operating Limits and Conditions of Membrane Element Max. Working Pressure 600 psi(4.14MPa) Max. Feed Water Temperature 45 Max. Feed Water Flow 17.0m3/h(8040),3.6m3/h(4040) Max. Feed Water SDI15 5.0 Free Chlorine Concentration of Feed Water 0.1mg/L pH Range of Feed Water during Continuous Operation 3-10 pH Range of Feed Water during Chemical Cleaning 2-12 Max. Pressure Drop of Single Membrane Element 10psi(0.07Mpa)
We produce reverse osmosis membrane is based on the usa environmental protection agency (epa), the department of health (nsi), nsf, fda, association of mechanical engineers (asme), association standard materials, european ce standard and domestic standards, and strict implementation of iso9001 quality certification system, to ensure that the quality of the products.The company currently has more than 10 senior engineers, to get the united states environmental protection registered engineer certification, advanced engineering and water treatment certification, vws certified engineers and many other professional certification. The company has consistently adhered to the pursuit of advanced production technology, the highest quality products and improve customer service. Has become the largest domestic product specifications, the largest production scale, access to one of the largest film patented technology manufacturers, product quality has passed iso9001 quality system certification and iso14001 environment system certificate.