The FK-5-1-12 Clean Agents, also known as NOVEC1230 Fire Suppression Agents, is a highly efficient and reliable hydro-fluorocarbon fire extinguishing solution. This product is designed to quickly and effectively suppress fires in various settings while being non-toxic, environmentally friendly, and safe to use. Model Number: FK-5-1-12 clean agents Product Name: NOVEC1230 Fire Suppression Agents Reliability: High Model NO.: FK-5-1-12 clean agents Application The FK-5-1-12 Clean Agents is suitable for use in various applications, including but not limited to: Commercial buildings Industrial facilities Data centers Telecommunication rooms Museums and art galleries Power generation plants Server rooms Control rooms Storage facilities
Product categories of Sensor Type of Fire Alarm, we are specialized manufacturers Sensor Type Of Fire Alarm, Sensor Type Fire Alarm suppliers/factory, wholesale high-quality products of Fire Alarm Sensor Type R & D and manufacturing, we have the perfect after-sales service and technical support. Look forward to your cooperation Here you can find the related products in Sensor Type of Fire Alarm, we are professional manufacturer of Sensor Type Of Fire Alarm,Sensor Type Fire Alarm,Fire Alarm Sensor Type,Fire Alarm. We focused on international export product development, production and sales. We have improved quality control processes of Sensor Type of Fire Alarm to ensure each export qualified product. If you want to know more about the products in Sensor Type of Fire Alarm, please click the product details to view parameters, models, pictures, prices and other information about Sensor Type Of Fire Alarm,Sensor Type Fire Alarm,Fire Alarm Sensor Type,Fire Alarm. Whatever you are a group or individual, we will do our best to provide you with accurate and comprehensive message about Sensor Type of Fire Alarm
SureFIRE fire alarm control panel provides a cost effective platform for a fire alarm system that is Reliable, Flexible and User-friendly. The panel has been designed with both installer and end user's requirements of Fire & Security Industry in mind. For installer, SureFIRE offers an out of the box and on the wall solution. Microprocessor controlled, user friendly design -16 Zones of Input -Reliable wide operating Voltage SMPS suitable for Indian Power Conditions -Regulated 24V for reliable Smoke Detector Operation -Standby Battery backup with CC/CV Battery Charger -Battery Low Voltage Cut-off to extend battery life -Drives upto 16 Hooters -Independent Potential free relays for Fire and Fault -Ethernet Connectivity Export-worthy Carton Box
Fire alarm control MIRA fire alarm control panel provides a cost effective platform for a fire alarm system that is Reliable, Flexible and User-friendly. The panel has been designed with both installer and end user's requirements of Fire & Security Industry in mind. For installer, MIRA offers an out of the box and on the wall solution. Microprocessor controlled, user friendly design -Reliable wide operating Voltage SMPS suitable for Indian Power Conditions -Operates from Single 12V, 7AH SMF Battery to save cost -Regulated 24V for reliable Smoke Detector Operation -Standby Battery backup with CC/CV Battery Charger -Battery Low Voltage Cut-off to extend battery life -Drives upto 4 Hooters -Independent Potential free relays for Fire and Fault Export-worthy Carton Packing
Intelligent fire Detection system as a high efficiency and low cost unmanned fire detection system in capable of an early detection regardless spontaneously fire or firebug. This system is located in outdoor area such small and middle sized cultureal assets, natural monument and outdoor facilities.
Features External (key-switch operated): Reset/resound/test zone lamps evacuate Silence alarm sounders Silence fault sounders Internal: One man detector test Zone isolate Revert to short-circuit: fire (no resistors in call points) External indicators: Sounder fault Battery/power supply fault Mains on Zone fire Zone fault Internal indicators: Open circuit zone fault Short circuit zone fault Zone isolated Engineer test selected Outputs: Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit) Ancillary connections for expansion modules will allow the following: Repeater panels Multiple sounder outputs Connection to landlord panel
Supplier: fire alarm control panel(fire detection system), fire detector, photoelectric smoke detector, heat detector, fire alarm bell, strobe siren, manual call point, LPG/natural gas detector, Carbon monoxide alarm, PIR detector(Motion detector) home security products
Specifications:- * Control key switch * Mains healthy indicator * Continuous alarm signal * Built-in battery * Polarity protection for battery * Push buttons for Evacuate, Reset and Alarm silence * Monitored alarm circuits for both open and short circuit * Individual sounder circuits for zones (optional) * Indicators for charger fault and battery fault * All controls are on front fascia * Knockouts on top and bottom sides for easy installation * Main supply - 240 V AC +/- 10%, 50/60 Hz * Battery supply - 24 V DC (Sealed Lead Acid) * Glass fuse protection - Main supply, Charging voltage, Sounder circuit, Reserve battery connection * Auxiliary relay contacts -30 V DC, 1 A, NO/NC