Characteristics of protection 1Phase loss protection: It means that any phase occurs phase loss when the protected circuit is in running or stopping status. In this case, the red indicator light will be lighted and be priority. 2Phase opposite protection: It is a safeguard acting immediately, which protects L1, L2, and L3 three phase against wrong connection sequence. In this case, the yellow indicator light will be lighted. 3.Voltage imbalance protection: While a protection of voltage imbalance rate > 8%, the imbalance of three phase voltage will affect the safe running of the equipment. In this case that there is a phase losing, the red indicator light will be lighted and be priority. 4.Delay protectionWhen the fault happens, the monitor will delay 1~2 seconds to act and release. Characteristics of performance 1.The protection functions of relay dont be affected by current intensity of circuit or load, impulse current, imbalance current and load characteristic. The relay could long term work under full capability and full climate. Power consumption is lower than 2W. 2There is no requirement for connecting method when it is used in protection of motor. 3This product measures up GB/T 14048.1-2000ã?�GB14048.5-2001 eqv IEC60947-1:1999. 4The EMC of the product measures up the limits and methods of measurement of radio disturbance characteristics of GB4343-1995.
Supplier: Food products, fruit and recreational plants, palm trees, generators, transformers, household electronics, ev charging stations, accumulators and battery systems, cooling appliances and frigotic systems for vehicles, furnitures (office and household types), copper tubes, powder metals for 3d printers, electrical equipment, defense products most notably drones (strategic /tactical), carrying boxes.
Services: Trade, sourcing and investment intelligence, supply chain development services, trade facilitation, inspection, operations support, full fledged trade/supply chain agency services
Buyer: High grade lead, zinc, antimony, manganese, iron ores.
Field Failure Relay (FFR) For D.C. Drives and Instrumentation The Field Failure Relay, when used in series with the field circuit, ensures that no power is supplied to the Armature unless Field circuit is complete. Field Failure Relay, also known as Field Loss Relay protects the D.C. Shunt motor or main circuit under open field conditions. Welcome to Insel Rectifiers: Your Premier Destination for Field Failure Relays At Insel Rectifiers, we take immense pride in being recognized as the forefront manufacturer and supplier of Field Failure Relays. Our commitment revolves around providing cutting-edge solutions that guarantee the reliability and efficiency of your systems. With a trusted legacy in the industry, we excel in the art of meticulously crafting precision-engineered Field Failure Relays and Field Loss Relays. Our dedication sets the benchmark for quality and innovation, ensuring your systems operate seamlessly and meet the highest standards of performance. Precision in Field Failure Relay Manufacturing At Insel Rectifiers, we take pride in our meticulous approach to manufacturing Field Failure Relays. These relays play a critical role in safeguarding your systems against unforeseen failures, and our commitment to precision engineering ensures that each relay meets the highest industry standards. As a distinguished Field Failure Relay manufacturer, we understand the importance of reliability in your operations. Efficient Solutions for Field Loss Relays Insel Rectifiers is your go-to source for efficient Field Loss Relay solutions. Our relay products are designed to detect and respond to field failures promptly, minimizing downtime and ensuring the seamless operation of your systems. As your dedicated Field Loss Relay supplier, we prioritize innovation to deliver cutting-edge solutions tailored to meet the unique needs of your applications. Innovative Technology, Trusted Supplier Insel Rectifiers is not just a manufacturer; we are your trusted partner in reliable relay solutions. Our commitment to innovation is reflected in the advanced technology embedded in our Field Failure Relays. As a leading Field Loss Relay supplier, we understand the importance of providing products that not only meet but exceed customer expectations. Why Choose Insel Rectifiers? Quality Assurance: Rigorous testing procedures ensure the reliability and durability of our Field Failure Relays. Innovation: We continually invest in research and development to bring you the latest advancements in relay technology. Customer Satisfaction: At Insel Rectifiers, your satisfaction is our priority. Our dedicated support team is ready to assist you with any inquiries or technical assistance.
Supplier: 1. semiconductor / display material, part, equipment
2. electrical/electronic material, part, equipment
3. medical / biomaterial, equipment
4. machine metal part
5. chemical materials
6. power parts
7. car parts
8. cosmetic
9. consumer goods
Services: Consulting and advisory services:
offering expertise and support for businesses engaging in international trade, such as compliance with trade regulations, market entry strategies, and risk management.
Buyer: Material, parts and equipment
Supplier: Agriculture product and garment product, marine oil, ship engine oil low sulphur fuel, propulsion oil, high sulphur fuel, gl4 oil, water resistant oil, cycle rickshaw & thela, stabilizer, electronic voltage corrector
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Supplier: 1. motorcycle helmets, accessories, 2. miniature circuit breaker, auto transfer switch for generators, pump controllers 3. generators upto 7.0 kva and welder generators 4. golf course maintenance equipment 5. battery operated inverters for home, office & factory use 6. bicycle display stands, parking stands etc. 7. wooden handicraft cutlery & gift items bed sheets and bed covers with pillow covers