Vibration test chambers are versatile equipment designed to carry out vibration tests by following international standards. Custom build shaker testing machine to perform specific temperature, humidity, and vibration tests. And also to improve the reliability of test equipments
1. Application Ultraviolet aging test chamber uses ultraviolet lamp as light source. By simulating the ultraviolet radiation and condensation in natural sunlight, accelerated weatherability test of materials is carried out to obtain the results of weatherability of materials. It can simulate the environmental conditions such as ultraviolet, rain, high temperature, high humidity, condensation and darkness in natural climate. By reproducing these conditions, it can merge into a cycle and let it automatically execute the number of cycles. 2. Standards Conforms with ASTM G 153, ASTM G 154, ASTM D 4329, ASTM D 4799, ASTM D 4587, SAE J2020, ISO 4892, all current UV aging test standards. GB/T14522-93 National Standard of the People's Republic of China--Accelerated Test Method for Plastics, Coatings and Rubber Materials for Machinery Industry Products-Artificial Climate GB/T16585-1996 National Standard of the People's Republic of China-Test Method for Artificial Climate Aging of Vulcanized Rubber (Fluorescent Ultraviolet Lamp) GB/T16422.3-1997 standard design and manufacture of plastic laboratory light source exposure test method. 3. Product Parameters Standard Configuration Editor For Test Box (1) Install 8 UV ultraviolet lamps on both sides of the studio. (2) Sample holder number: 20 pieces. (3) Sample holder size: 404 x 105 (mm) (4) The heating mode is inner tank water heating, fast heating and uniform temperature distribution. (5) The drainage system uses the return vortex type and U type sedimentation device to drain the water. (6) The distance between the surface of the sample and the ultraviolet lamp is 50 mm and parallel. (7) The actual workroom is made up of test samples and brackets. (8) Internal water level automatic replenishment. (9) The box cover is bidirectional flip type, easy to open and close. (10) The bottom of the test box adopts high quality and fixed PU wheel. 4. Power Supply Condition Editor Power requirements: AC380V ± 10% 50 ± 0.5Hz three-phase five wire system. Preinstalled power: total power +2.0KW Users are required to install air or power switches for the equipment at the installation site.
Tempered Glass Quality Testing Equipment Function: Determining the resistance of glazing material to impact by the penetration method. Principle: The specimen is supported vertically in a steel frame and an impact shot bag is released from a pre-determined height to strike the specimen at the centre. The height is progressively increased until fracture occurs. Related Standards: AS/NZS 2208 Safety glazing materials in buildings Appendix D: Impact Test GB 15763.3 Safety glazing materials in building Part 3: Laminated glass Appendix C: Test device for the impact performance of shot bag ANSI Z97.1 Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of Test - Clause 5.1: Impact Test Apparatus: 1) Impact testing frame: Frame Size: 1900mm*1500mm*3570mm Samples Size: 1930mm*864mm Lift: Electric Release: Auto Maximum impact height: 1200mm (customized) Rubber Pad Width: 15mm Rubber Pad Thickness: 3mm Rubber Pad Hardness: Shore A50 2) Impact shot bag: Weight: 45kg ±0.1kg 46kg ±0.1kg Height: 330mm ± 13mm Max diameter: 250mm Leather thickness: 1.5mm Lead sand size: 2.5mm Customized: 25kg /48kg
Frame Size: 1900mm*1500mm*3570mm Samples Size: 1930mm*864mm Lift: Electric Release: Auto Maximum impact height: 1200mm (customized) Rubber Pad Width: 15mm Rubber Pad Thickness: 3mm Rubber Pad Hardness: Shore A50 Impact Shot Bag: Reinforced leather bag filled with chiller lead shot
Frame Size: 1900mm*1500mm*3570mm Samples Size: 1930mm*864mm Lift: Electric Release: Auto Maximum impact height: 1200mm (customized) Rubber Pad Width: 15mm Rubber Pad Thickness: 3mm Rubber Pad Hardness: Shore A50 Impact Shot Bag: Reinforced leather bag filled with chiller lead shot
Tempered Glass Impact Strength Test Equipment Function: Determining the resistance of glazing material to impact by the penetration method. Principle: The specimen is supported vertically in a steel frame and an impact shot bag is released from a pre-determined height to strike the specimen at the centre. The height is progressively increased until fracture occurs. Related Standards: AS/NZS 2208 Safety glazing materials in buildings â?? Appendix D: Impact Test GB 15763.3 Safety glazing materials in building Part 3: Laminated glass â?? Appendix C: Test device for the impact performance of shot bag ANSI Z97.1 Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of Test - Clause 5.1: Impact Test Apparatus: 1) Impact testing frame: Frame Size: 1900mm*1500mm*3570mm Samples Size: 1930mm*864mm Lift: Electric Release: Auto Maximum impact height: 1200mm (customized) Rubber Pad Width: 15mm Rubber Pad Thickness: 3mm Rubber Pad Hardness: Shore A50 2) Impact shot bag: Weight: 45kg�±0.1kg 46kg�±0.1kg Height: 330mm �± 13mm Max diameter: 250mm Leather thickness: 1.5mm Lead sand size: 2.5mm Customized: 25kg /48kg
ZY6014A (Vertical-specimen) Flame Tester 1.Introduction: This apparatus is certificated by Guangzhou Hua Mei UL company ,it applies to research and manufacture for illumination, household, machine tool, motor, and such electric and electronic equipments and parts. It is also used to insulation materials, project plastics and other materials. 2. Standards: UL1581(section 1080.1£1080.14) , UL13. UL14 UL1655(VW-1 burning test). CSA (FT-1¡¢FT-2) 3. Main components: burning chamber ¡¢observation Windows¡¢ operation windows¡¢control system ¡¢gas control and so on . 4. Main parameters : 4.1 Burning chamber outside size: 2.4m(L)*1m(W)*2.5m(H) 4.2 Observation Windows: 3 observation Windows, made by reinforced glass, size: 730mm(H)*420mm(W) 4.3 Operation windows: 4 operation windows, interior diameter 150mm, outside diameter 220mm.sealed by 600mm long-arm leather glove. 4.4 Air inlet : 4 air inlets ,which diameter is 160mm, 4.5 Bottom anchor : bottom anchor size 2.4(L)*1m(W)*0.7m(H), 6 pulleys of which 4 are with lock. 4.6 Light equipment : 1 anti-fog,anti-smoke,ring lamp. 4.7 Control system: 1 sheet of burning instrument, 0 to 99.99s setting arbitrarily. 1 sheet of stop burning instrument, 0 to 99.99s setting arbitrarily . 0 to 999999 times setting arbitrarily. negotiable
ZY6056 Needle Flame Tester 1. Introduction : This device applies to electrical and electronic equipment and components ,also suitable for electrical insulating materials or other solid materials ,using simulation technology assess dangerous of catching fire or flame driven from internal equipment under fault condition. 2. Standards: IEC60695-2-2. GB/T5169.5-1997. 3. Main components: needle combustor, temperature measurement system , test chamber and so on. 4. Main parameters 4.1 Burner :inner diameter 0.5mm, length 35mm. 4.2 Flame standard : length more than 12mm. 4.3 Heat speed :100 - 700C costs 2.5S 4.4 Chamber capacity 0.5M 60cm(L) * 95cm(W) * 90cm(H) 4.5 Conductive copper ¥Õ4.0 * 6.0mm, 4.6 Outsize :61cm(D) * 120cm(W) * 105cm(H).
ZY6078 Vulcanization Tester 1. Introduction : This device applies to show vulcanization curve , so that a new hand can easily get the best reasonable ingredients and balanceable formula of scorching and vulcanization by computer and software . 2. Main components : 2.1 Machine parts: cabinet , upper and bottom mould cavity ,and so on. 2.2 Electrical control system 2.3 Printer 2.4 Pneumatic system.
ZY 6192 Halogen Release Measurement Device 1. Introduction: this device applies to measure halogen content PH conductivity when wires and cables are burning according to IEC60754. 2. Standards:GB/T17650.1-1998, GB/T17650.2-1998, IEC60754-1:1994, IEC60754-2:1991 . GB/T19666-2005, GA306.1-2007, GA306.2-2007, UL2556-2007. 3. Main components : quarts material tubular furnace combustion tube, air collection system, air supply system , PH meter , conductivity analyzer 4. Main parameters: 4.1 Tubular furnace chamber size : 42mm * 600mm, power input :220V/10kw. 4.2 Combustion tube 40mm, 4.3 PH meter : precision 0.02PH. 4.4 Conductivity : measurement scope :(0~1¡Á105)¦ÌS/ cm. 4.5 Air flex meter :20-200L adjustable.