PE coil pipes and tubes for water and wire cable conduit PL231
The PE coil pipes and tubes can be used:
water pipe 4 â?? 6 â?? 1-inch black coil with pressure 1.6mpa, OD 20-75mm, WT 2.3-6.8mm
pe conduit cable embedded wire cable and optical cable, OD 20-200mm, WT 1.8-3.5mm
weak current protection tube and communication tube, OD 20-200mm, WT 1.8-3.5mm
We use new 100% pure raw PE material
WHY NEW MATERIAL HDPE PIPES?
1. Health performance
PE pipe processing without adding heavy metal salt stabilizer, no scaling layer, and no bacteria.
2. Corrosion resistance
It can resist various chemical media erosion, with no electrochemical corrosion.
3. Service life
Under rated temperature and pressure conditions, PE pipes can be used for more than 50 years.
4. Impact resistance
PE pipe toughness, high impact strength, heavy objects directly pressed through the pipeline will not break.
5. Connection performance
The strength of the hot melt or electric melt interface of the polyethylene HDPE pipe is higher than that of the pipe body, and the joint will not be broken due to soil movement or live load.
6. Construction performance
It has a lightweight pipe weight, a simple welding process, convenient construction, and a low overall project cost.
EVT threaded conduit body for rigid conduit or IMC allows access for general inspection, maintenance and wire pulling. Conduit body saves time and money by eliminating costly bending of large conduits in order to change the directions of conduit runs. Its powder-coated finish and neoprene gasket ensure a weatherproof installation.
EMT is short for Electrical Metallic Tubing. EMT tube, also commonly called thin-wall, is a steel raceway of circular cross section, which is unthreaded, and nominally 10² long. EVT EMT conduit is UL listed with UL file number E476073. EMT electrical is manufactured according to UL 797, CSA C22.2 NO.83.1 and ANSI C80.3, Electrical Metallic Tubing â?? Steel.
EMT Tubing is available in trade sizes 1/2 through 4. The steel conduit is galvanized both inside and outside for corrosion protection. EMT pipe is commonly installed by use of set-screw or compression type connectors and couplings.
Application:
Used with a locknut to terminate threaded rigid and imcconduit to a box or enclosure and to provide a smooth pulling surface. Thermoplastic liner prevents damage to wire insulation. Liner rated at 150c..
Features:
The plastic liner wont chip, crack, swell or shrink. It resists corrosion, chemicals, and temperature extremes.