Brief Introduction: MR-JL269 gas detector for industrial use has a high performance and wide detecting range. It can be used to detect methane, natural gases, propane, LPG, Hydrogen and other combustible gases and find the gas leaking point easily. Features: - Calibration-free on gas sensor - Quick response to combustible gas leakage - Long and flexible gooseneck tube - Adjustable sensitivity - 30-level LED / tricolor show - Battery low voltage alert - Sensor fault self test Specifications Sensor type£ºSemi-conductor gas sensor Detecting gas£ºFlammable gases Gas sampling£ºNatural diffusion Response time£º¡Ü5S Sensitivity£ºBetter than 50ppm Working temperature.-10¡æ-55¡æ Working humidity£º¡Ü93£¥RH Storage temperature£º-30¡æ-60¡æ Storage humidity£º¡Ü93£¥RH Power supply£º3.6V Ni-MH 1600mAh rechargeable battery Charging time£º4 to 6 hours Continuous working time£ºNot less than 8 hours £¨normal working status£© Sensor life£º2 years Dimension and weight£º180mm¡Á72mm¡Á35.5mm about 300g carton box and gift box, according to requirement
Features: - Natural diffusion sampling method and high-sensitivity sensor, with high sensitivity and repeatability - 32-bit built-in MCU, high reliability and self-adaptation ability - Full functions, easy operation - CSTN colorful LCD, more intuitionistic, abundant and clear indication - Compact design, easy carrying - High strength engineering plastics and compound anti-slippery rubber; high strength, water-proof, dust-proof and explosion-proof Spcification: - Gas sampling method: Natural diffusion - Gas sensor type: Catalytic and electrochemical - Detecting gas: Combustible gas, H2S, CO, O2 - Accuracy:
Specifications: Sensor type: Catalytic sensor, fuel cell sensor, electrochemical sensor Gas sampling: Diffuse naturally Accuracy: < +/-3% F.S. Response time:
Supplier: Japanese quality switchgear components, breakers, magnetic contactors, switches, pilot lights, pushbuttons, panel instrumentations, power management meter, protection relays, transformers, inverters, ups.
Flat Cable M&P is able to support a full line of flat cable and flat ribbon cable for electronic applications. Providing both power and data transmissions, flat cables are mainly used for internal connections within the equipment. They are available in a wide range of configurations to accommodate different connection and data transmission requirements and the range of sizes of the equipment using the cables. Flat cables provide consistent performance due to their layout and the spacing between the cables and are lighter, thinner and more flexible than other cables. Features of Our Flat Cables & Wire * Flat, ribbon and twisted configurations, with different levels of flexibility. * Shielded or jacketed cable to reduce signal interference. * Range of pitches and pin configurations to accommodate the application requirements. * Easy to fasten with clamps, adhesive, and tape. We provide custom services, including marking, kitting and custom cable design to provide you with a custom solution for your cabling application. Contact us to find out more about Flat Cables and Wires.
- Material : Stainless Steel Core, Polyethylene Yarn, Span Yarn - Number of Stitiches : 10 Gauge - Length : 14 inch - Cut Level : 5 - Color : Gray, Black, White - Packing : 1pair/individual packing (1pack=5pair, 1box=200pair) - Origin : Made in South Korea - Purpose : Cut Resistant
Supplier: Industrial weighing scale, frls panel, plc hmi, Diesel Diesel Generator Set, Compression Force Transducer, Tension/Compression Force Transducer, Bending/Shear Beams, Load Pins
Product advantages: ï?¬All-in-one design, high integration and space saving installationï¼? ï?¬Using high-performance lithium iron phosphate cells, laser welding, good cell consistency, designed service life of more than 10 yearsï¼? ï?¬Master-slave mode, passive equalization, can manage the equalization resistance, can set the equalization start voltage difference, and monitor the equalization resistance temperature, more intelligent and safe, and reduce the impact of barrel effect on system energy storage BMS adopts NXP(USA) automotive-grade high-performance chips, with strong anti-interference, good reliability and wide temperature range CAN2.0 communication interface, has the advantages of strong real-time performance, long transmission distance, strong anti-electromagnetic interference ability System parameters can be set through the host computer, such as fan start/stop temperature, charger maximum current setting, charge and discharge current correction, SOC correction, with insulation leakage detection function to prevent oil leakage and short circuit of the cell Integrate Solar charge controller or AC charger optional, BMS communication control, more safe and reliable; Cell temperature management, can be automatically controlled with the air conditioner heater according to the cell condition to make the cell works at the most suitable temperature, and can be linked with the fire protection system as needed Performance characteristics Built-in BMS management system with comprehensive protection and monitoring control functions 5" LCD screen display, easy to operate, can check the temperature, voltage, working status, discharge current, dynamic and static SOC algorithm of a single cell, local display of alarm info, alarm level distinction, accurate positioning of abnormal cells Main control MCU can be centrally controlled and manage peripheral settings (AC charging module, inverter module, solar charging module) to adjust the charging current and voltage of peripheral devices according to the battery charging curve, making the system more reliable BMS battery management system, with SOC automatic calibration and high current passive balance function, combined with perfect operation control and management strategy, to achieve accurate and efficient management EMS energy management system, BMS with solar controller/AC charger, inverter centrally manages charge and discharge, effectively controls the charge and discharge current within the cell usage conditions, protects the cell and extend its service life
1 All-in-one design, high integration and space saving installation 2 Using high-performance lithium iron phosphate cells, laser welding, good cell consistency, designed service life of more than 10 years 3 Charging and discharging are controlled separately, which is convenient and reliable to control charging and discharging. The discharge port will not be disconnected when over-charging, and the charging port will not be disconnected when over-discharging, the system has good stability 4 Master-slave mode, passive equalization, can manage the equalization resistance, can set the equalization start voltage difference, and monitor the equalization resistance temperature, more intelligent and safe, and reduce the impact of barrel effect on system energy storage 5 BMS adopts NXP(USA) automotive-grade high-performance chips, with strong anti-interference, good reliability and wide temperature range 6 CAN2.0 communication interface, has the advantages of strong real-time performance, long transmission distance, strong anti-electromagnetic interference ability 7 System parameters can be set through the host computer, such as fan start/stop temperature, charger maximum current setting, charge and discharge current correction, SOC correction, with insulation leakage detection function to prevent oil leakage and short circuit of the cell 8 Integrate Solar charge controller or AC charger optional, BMS communication control, more safe and reliable; 9 Cell temperature management, can be automatically controlled with the air conditioner heater according to the cell condition to make the cell works at the most suitable temperature, and can be linked with the fire protection system as needed Performance characteristics 10 Accurately estimate the state of charge of the battery pack, that is, the remaining power of the battery, to ensure that the power of the battery pack is maintained within a reasonable range 11 Built-in BMS management system with comprehensive protection and monitoring control functions 12 5" LCD screen display, easy to operate, can check the temperature, voltage, working status, discharge current, dynamic and static SOC algorithm of a single cell, local display of alarm info, alarm level distinction, accurate positioning of abnormal cells 13 Main control MCU can be centrally controlled and manage peripheral settings (AC charger, inverter, solar charger) to adjust the charging current and voltage of peripheral devices according to the battery charging curve, making the system more reliable