Model, sh-fs150 Applicable fibers, sm (itu-t g.652), mm (itu-t g.651), ds (itu-t g.653), nzds (itu-t g.655) Fiber cleaved length, 10 ~16mm (coating diameter
Sharingtek Sh-fs150 Optic Fiber Fusion Splicer Descriptions Digital Fusion Splicer With Automatic Focus Function 5.6 Inch Tft Color Lcd Monitor With Clear Digital Image Display Usb & Vga Interface Software Upgrade Via Usb Interface Specifications Model, Sh-fs150 Applicable Fibers, Sm (itu-t G.652), Mm (itu-t G.651), Ds (itu-t G.653), Nzds (itu-t G.655) Fiber Cleaved Length, 10 ~16mm (coating Diameter
Applicable fiber SM (ITU-T G.652), MM (ITU-T G.651), DS (ITU-T G.653), NZDS (ITU-T G.655), others(including G.657) Cladding diameter 80 -150m Coating diameter 160 900m Typical splice loss SM 0.02dB, MM 0.01dB, DS 0.04dB, NZDS 0.04dB Return loss
Applicable fiber SM (ITU-T G.652), MM (ITU-T G.651), DS (ITU-T G.653), NZDS (ITU-T G.655), others(including G.657) Cladding diameter 80 -150m Coating diameter 160 -900 Typical splice loss SM 0.02dB, MM 0.01dB, DS 0.04dB, NZDS 0.04dB Return loss
Small, light, long battery life 4 motors accurate core alignment 250 times magnification of fiber cores 7s fast splicing, 26s intelligent heating More than 4000 times electrodes discharging 4400mAh Li-battery, 220 cycles splicing and heating Inductive automatic heater, not heating without fibers 3 in 1 multi-function clamps, new waterproof structure Apply to bare fibers, drop cables and jumper wires splicing
Applicable fiber SM(G.652), MM(G.651), DS(G.653), NZDS(G.655), others(including G.657) Fiber count Single Applicable fiber dimensions Cladding diameter: 80 -150m, Coating diameter: 160 -900m Typical splice loss 0.02dB(SM), 0.01dB(MM), 0.04dB(DS), 0.04dB(NZDS) Return loss >60db Fiber cleaved length 10-16mm (coating diameter< 250m ), 16mm(coating diameter: 250-1000m ) Splicing program 40 groups Operate mode Manual, Automatic Auto-heating Available Typical splicing time 8 seconds Tube heating time 26 seconds for 60mm and 40mm shrinkable sleeves Fiber view magnification 250X(X or Y view), 125X(X and Y view) Viewing method and display 2 CMOS cameras, 4.3 inch color LCD monitor Storage of splice result 4000 results Loss evaluation Available Tension test 1.8-2.2N Interface GUI menu interface, easier operation Battery capacity 5800mAh, typical 180 cycles(splice and tube heat), pluggable inner Li-battery Power supply Adaptor, input: AC100-240V(50/60HZ) Electrode life More than 4000 ARC discharges, can be replaced conveniently Terminals USB 2.0 port, for uploading splice results and upgrading software Operating condition Altitude: 0-5000m, Humidity: 0-95%, Temperature: -10â??ï½?+50â??;Wind speed: max 15m/s Dimension 149mm(L)x120mm(W)x127mm(H) Weight 1.9kg including battery Applicable fiber SM (ITU-T G.652), MM (ITU-T G.651), DS (ITU-T G.653), NZDS (ITU-T G.655), others(including G.657) Cladding diameter 80 -150m Coating diameter 160 -900 Typical splice loss SM 0.02dB, MM 0.01dB, DS 0.04dB, NZDS 0.04dB Return loss
Technical Specifications1 Wavelength (nm) 1310/1550 Dynamic range (dB)2 38/36, 32/30 Pulse width (ns) 5,20,40,80,160,320,640,1280,2560,5120,10240,20480 Event blind zone (m)3 2m Attenuation blind zone (m)3 9m Linearity (dB/dB) ±0.05 dB/ dB Loss threshold (dB) 0.05 Loss resolution ratio (dB) 0.01 Sampling resolution ratio (m) 0.125 to 8 Sampling point 32K Distance uncertainty (m) ±(1 m + 510-5 distance + sampling interval) Distance scope (km) 0.3 to180 Typical real-time refreshing duration (s) 0.2 Memory capacity of trace SD Card (2G), > 10000 pieces Duration of measurement Defined by user; 5sec, 10sec, 15sec, 30sec, 1min, 2min, and 3min are selectable General specification Dimension (HWD) 15023566 Weight 1.5kg Temperature Running temperature -10 to 50 Memory temperature -40 to 70 Relative humidity 0% to 95% (non condensation) Power supply Lithium battery; continuing working duration ?¥ 8 hours Warranty period 12 months Remarks: 1. The technical specification describes the ensured performance of the instrument when using typical PC model connector to measure. Without considering the uncertainty caused by optical fiber refractivity.2. Dynamic range is the data measured under the condition of the maximum pulse width and 3 minutes of average time. Dynamic range is the data measured under the condition of 180km/20480ns/3min. 3. Measuring conditions of blind zone: reflection event is within 4Km, reflection strength < -35dB. Measured by the minimum pulse width.
Wavelength(nm) 800~1700nm Detector InGaAs Measurement? Range (dBm) -70~+3 -50~+26 Uncertainty ±5% Calibrated Wavelength(nm) 850,1300,1310,1490,1550,1625 Resolution(dB) 0.01 Optical Connector FC(interchangeable SC,ST) / as well as 2.5mm universal Power Supply Alkaline Battery(3 AA 1.5V batteries) Battery Operating Time 240 h with 1.5V Battery(3) Operating Temperature() -10 ~ +60 Storage Temperature() -25 ~ +70 Relative Humidity 0 to 95% (non-condensing) Dimension(mm) 200 X90 X50 Weight(g) 285
Operating wavelength(nm) 1310/1550 (others specify on requests, Max wavelength is 5 Applicable fiber SM ,MM Laser type FP-LD(others specify on requests) Maximum Output Power(dBm) -7(can be adjustable, others specify) Stability(dB, 15min, 20) ±0.1 Stability(dB, 30min, 20) ±0.05 Modulation(Hz) CW, 270, 1K, 2K Fiber Port FC/PC or FC,SC,ST interchangeable Alkaline Battery 3XAA, 1.5V Battery Operating time(h) 45 Operation Temperature() -10+60 Storage Temperature() -25+70 Outline sizemm 200 X90 X50 Weight(g) 285