Turbine Flow Meters which have advantages of simple structure, light weight, high accuracy and easy installation, measure liquid which has no impurities and no chemical corrosive reaction with stainless steel . The measurable liquids include water , diesel and methanol, etc. FINE-FLOW FLOW METERS BY H&L FROM KOREA FEATURES Wide range of liquid measurement High accuracy and excellent repeatability Easy installation and energy saving Easy to read LCD Back light. Specific Gravity Correction 0.01 2.00 Display Accumulated amount reset, accumulated flow display, instantaneous flow rate display, gallon or liter unit change, automatic integration Lamp indication Flow display Battery life 4 5 years Auto on and off
An ultrasonic flow meter is a type of flow meter that measures the velocity of a fluid with ultrasound to calculate volume flow. Using ultrasonic transducers, the flow meter can measure the average velocity along the path of an emitted beam of ultrasound, by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direction of the flow or by measuring the frequency shift from the Doppler effect. Ultrasonic flow meters are affected by the acoustic pr
Size:DN6 Flow range:0.1-0.6m3/h Without display, 2 wire Output:4-20mA Connection:screw Body material:SS304 Power supply:24V Accuracy1% Temperature:-20-+120C carton case/wooden case/plywood case
Meter diameter (mm): And the connection mode 25,40,50,65,80,100,125,150,200,250,300 use flange connection Precision grade ±1.5%R,±1.0%R,±0.75%R(special) Quantity range: 1:10;1:20;1:30 Instrument material: 304 stainless steel;Impeller: anticorrosive ABS or high quality aluminum alloy;Monitor: cast aluminum Measured medium temperature (?) : -30?~+80? Environmental conditions of temperature :-20?~+60? , relative humidity 5%~90% , atmospheric pressure 86 ~ 106 kpa The output signal Sensors pulse frequency signal, the low level 0.8 V or less, high level 8 V or higher two wire system 4 ~ 20 madc current signal Power supply VOLTAGE + 12 VDC and + 24 VDC (optional) + 24 VDC Display type instrument comes with 3 v lithium battery Signal transmission line STVPV3 x 0.3 (three-wire system), 2 x 0.3 (two wire) transmission distance =1000m Protection IP65 Explosion-proof grade basic ExdIIBT6
Introduction CJW01 Turbine Flow Meter is a new generation of turbine flow meter, which absorbs the advanced technology of flow meters at home and at abroad, and has the characteristics of simple structure, light weight, high accuracy, good reproducibility, sensitive response, easy installation and maintenance. It is matched with the display instrument with special functions.It can also carry out quantitative control, excessive alarm and so on. It is an ideal instrument for flow measurement and energy saving. Features Simple Structure Light weight High accuracy Good reproducibility Sensitive response Easy installation and maintenance Technical Parameter Standard turbine flowmeter (JB/T9246-1999) Instrument caliber& connection methods: 4, 6, 10, 15, 20, 25, 32, 40 with threaded connections; 15, 20, 25, 32, 40) 50, 65, 80, 100, 125, 150, 200, flanged connections Precision grade: + 1%R, + 0.5%R, + 0.2%R (customize) Meassure Range: 1:10, 1:15, The instrument body material: 304 stainless steel or aluminum Impeller: anticorrosion ABS or high quality aluminum alloy Converter: cast aluminum Usage Condition: medium temperature: -20 C ~ +80 C environment temperature: -30 C ~ +60 C Relative humidity: 5% ~ 90% Atmospheric Pressure: 86KPa ~ 106Kpa Working Power Supply: A: power supply: +24VDC + 15%, rippleâ?¤5%, suitable for 4 ~ 20mA, pulse output, RS485 etc. B: 1 group 3.0V010AH lithium battery, the battery voltage can work normally from 2 to 3.0V Overall power consumption A: external power: < 1W B: Internal power supply: average power consumptionâ?¤1W, more than three years of continuous use Analog output: pulse signal, 4 ~ 20mA current signal, control signal Communication output: RS485 Real time record, Start and stop record, diary, fixed time interval record Internal thread: M20*1.5 of or user self determination Explosion-proof grade: ExdIIBT6 or ExiaIICT4 Protection grade: IP65 Product Application Widely used for measuring the closed pipes and stainless steel 1Crl8Ni9Ti, 2Cr13 and AI203, corundum hard alloy do not corrode, and no fiber, particles and other impurities. When working temperature, kinematic viscosity should be less than 5 * 10-6m2/s liquid. When kinematic viscosity greater than 5 x 10-6m2/s liquid, can label flow meter actually before use
Sanitary tri-clamp turbine flow meter Installation Instruction Features Measurement is not affected by the variation of flow density, viscosity, temperature, pressure and conductivity. High accuracy measurement is guaranteed according to the linear measurement principle. No obstacle in the pipe, no pressure-loss and lower requirement for straight pipeline. DN 6 to DN2000 covers a wide range of pipe size. A variety of liners and electrodes are available to satisfy different flow characteristic. Programmable low frequency square wave field excitation, improving measurement stability and reducing power consumption. Implementing 16 bits MCU, providing high integration and accuracy; Full-digital processing, high noise resistance and reliable measurement; Flow measurement range up to 1500:1. High definition LCD display with backlight. RS485 or RS232 interface supports digital communication. Intelligent empty pipe detection and electrodes resistance measurement diagnosing empty pipe and electrodes contamination accurately. SMD component and surface mount technology (SMT) are implemented to improve the reliability.
This manual will assist you in installing, using and maintaining your flow meter. It is your responsibility to make sure that all operators have access to adequate instructions about safe operating and maintenance procedure. Operating Principle: Liquid flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil. This signal is converted into engineering units (liters, cubic meters, gallons etc.) on the local display where is applicable. Optional accessory modules can be used to export the signal to other equipment. Upon receipt, examine your meter for visible damage. The turbine is a precision measuring instrument and should be handled carefully. Remove the protective plugs and caps for a thorough inspection. If any items are damaged or missing, contact us. Make sure the turbine flow model meets your specific needs. For your future reference, it might be useful to record this information on nameplate in the manual in case it becomes unreadable on the turbine. Refer to the nameplate for your customized products specification. . Cautions for Installation turbine type flow meter 4.1 Mounting Positions â?¢ Pipes must be fully filled with liquids. It is essential that pipes remain fully filled at all times, otherwise flow rate indications may be affected and measurement errors may be caused Avoid Air Bubbles. If air bubbles enter a measurement pipe, flow rate indications may be affected and measurement errors may be caused Avoid all pipe locations where the flow is pulsating, such as in the outlet side of piston or diaphragm pumps. Avoid locations near equipment producing electrical interference such as electric motors, transformers, variable frequency, etc.
The Electronic Digital Display Turbine Liquid Flowmeter is a precision instrument designed for the accurate measurement of liquid flow in various industrial applications. This device utilizes a high-performance turbine mechanism to measure the volumetric flow of liquids with high accuracy and repeatability. The built-in digital display provides real-time data on flow rate, total flow, and other relevant metrics, making it easy to monitor and control fluid systems. Applications: Water and wastewater management Oil and gas industries Chemical processing Food and beverage industries Irrigation systems Fuel monitoring in automotive and aviation sectors
This manual will assist you in installing, using and maintaining your flow meter. It is your responsibility to make sure that all operators have access to adequate instructions about safe operating and maintenance procedure. Operating Principle: Gas flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil. This signal is converted into engineering units (liters, cubic meters, gallons etc.) on the local display where is applicable. Optional accessory modules can be used to export the signal to other equipment. Upon receipt, examine your meter for visible damage. The turbine is a precision measuring instrument and should be handled carefully. Remove the protective plugs and caps for a thorough inspection. If any items are damaged or missing, contact Make sure the turbine flow model meets your specific needs. For your future reference, it might be useful to record this information on nameplate in the manual in case it becomes unreadable on the turbine. Refer to the nameplate for your customized products specification.
Turbine flow meter.
Turbine flow meter.
Turbine Flow Meter.
Warranty:2 years Type:Flow Sensors, For Water Customized support:OEM, Customized logo, Customized packaging, Graphic customization Model Number:J-MAG Medium:Conductive Liquid Connection:Flange Accuracy:0.2%/ 0.5% Output:4-20mA /RS485/HART Application:Water Flowrate Measure Power Supply:DC24V, 220V Measurement Range:0-1000 (m3/h) Material and Color:Stainless Steel SUS304 Extrode:316L
Size DN3-DN3000 Electrode:SS316,HC,HB,Ti,Tan,Pt Liner Material: PTFE,PFA,FEP,NEOPRENE,HARD RUBBER Accurance: 0.5% of reading velue,0.3% and 0.2% optional Connection: Flange,Tri-clamp,Wafer,Union Introduction Electromagnetic flow meter is hallmarked by its high performance and reliability based on successful, field-proven technology. It is being widely used in industries such as petroleum, chemical engineering, iron and steel, food, electricpower, paper making, water treatment, petrochemical, medicine etc Features Medium temperature can be -20~200. Integrated vertification, diagnostic function and empty pipe detection. Measure forward and reverse direction flows. Built-in reference electrodes, no need to connect ground ring. Dual frequency excitation and stable zero point. Precision coil winding technology, makes magnetic field more uniform. High protection grade,IP65. No moving parts, no pressure loss. High accuracy: ±0.5% of reading,±0.3% and ±0.2% optional, velocity >0.3 m/s. Application Chemical Medicine Beverage Iron and steel Water supply Electricpower Water treatment
Open Channel Flow Meters
Are electromagnetic flowmeter, vortex flowmeter, turbine flow meter.Manufacturer
HVT-Halmi Venturi Flow Meters
Water Milk Analog Magnetic Flow Meter Price Electromagnetic Flowmeter Wastewater Flow Meter, Mechanical Smart Electromagnetic Flowmeter Quick Details: Place of Origin Henan, China (Mainland) Brand Name WEILI Model Number MGG Product Name MGG Medium Corrosive Accuracy 0.5% Power supply 220VAC/ 24VDC Output 4-20mA /RS485 Application Measuring Liquids Connection Thread Material Stainless Steel Type Integral Product Description: Magne W3000 PLUS Sanitary Centrifugal type Electromagnetic flowmeter adopting new sanitary centrifugal liner and technology ,which is in line with the food industry hygiene requirements , At the same time, its stainless steel shell connected with stainless steel clamp ,easy to remove and clean , so that the flowmeter can not easily be contaminated in using process and applied in food manufacture processing of Mineral water, soy sauce, jam, beer, fruit juice, rice, milk ,etc and Health and chemical industry . Nominal Bore DN10ï½?DN300mm Nominal Pressure 1.0ï½?4.0MPa Accuracy ±0.5%ï¼?±0.3% Flow range 0ï½?10m/s(Flow Velocity) Liner materia PFA Measuring Electrodes 316L Stainless steel , Harrington alloy B/C, Titanium , Tantalum Shell material Stainless steel Medium temperature Remote type-10 ~+160 ,Integral type -10 ï½? +80 Connection Mode ISO Standard Quick Connector Main Features: 1) It adopting new sanitary centrifugal liner,that prevent the residue of measured media accumulated in the measuring pipe . 2) It used Fast Connection program and makes the demolition of the electromagnetic flowmeter, maintenance and cleaning to be facilitated. 3)It uses 16 digit embedded Super-Micro power consumption Microprocessor ,meanwhile adopts special technical designing excitation system of sensor ,having the functions such as higher integration ,fast in operational speed ,best accuracy in calculation ,digital signal processing ,strong capability of interference immunity ,stable and reliable measurement. 4)The flowmeter is a two-way measurement system with three totalizers: positive total, reverse total and total difference; can display positive and negative flow, and has multiple outputs: current, pulse, digital communication, HART protocol.
Based on the measurement theory of flow meter, ZERO instrument developed a series of novel pressure influence target mode flow meters which utilize the modern sensor and computer technology. They have not only immovable characteristics such as of the Target Flow meter, Hole Board Flow meter and Turbine Flow meter, but also measure accuracy comparable to Cub age Flow meter. Since their characteristic of anti-interfere, anti-impurity, portability and reliability, they have been widely used in many fields of petroleum, chemical industry, energy, foodstuff, environment protection, water conservancy and so on. The flow meters are applicable to the following ranges:: Diameter ,152000mm or bigger. High and low temperature, -196+450. High pressure : 0 2) Characteristics Measurement flow of liquid, gas, steam, ropy mediums or ambulatory mediums in low, normal or high temperature condition. Total quantity measurement accuracy is not less than 0.2%. High sensitivity, able to measure very low velocity below 0.8m/s. No movable part, safe and reliable. Wide measure range, bigger than 1:30. Good repeatability, generally 0.108% , fast to measure. Small pressure loss, only about 1/2P of Standard Hole Board. Able to adopt hang weight method to test the flow meter. Measurement range can be changed by replacing target according to need. LCD display. 4-20mA, 0-10V, impulse, and RS485 outputs. Easy installation and maintain.
Ferent flow signal; 6. Inside have three counters, which can separately show positive cumulation, reverse cumulation and d-value Flow direction forward / reversed Electrodes material 316l / hastelloy c2, b4/tantalum/titanium/platinoiridita/others Liner material rubber /ptfe/pfa pfa ptfe Electrodes type standard Qty of electrodes 2 pairs ( one pair for measuring, one pair for grounding) 1 pair( for measuring) Measuring tube material 304 stainless steel Flange material carbon steel/304 stainless steel 304 stainless steel 304 stainless steel Installation type wafer/flange tri-clamp/screw flange/plug-in Protection level ip65/p68 ( remote version) Power 220vac ± 20% 60hz / 24 vdc Signal output 4~20ma Communication hart / modbus/ profibus Electrical connection 2* m20 * 1.5 Explosive-proof exdemib ii bt3~t6 Construction type compact / remote Operation environment environment temperature: -25 ° c~ + 60 ° c; relative humility: 5% ~90% Wooden box