Descriptions: SDS616 sulfur analyzer is used to determine the total sulfur content in coal, coke, petroleum and other combustible materials. Conformance with standards: GB Specifications: Test range: 0.01%~35% Sample weight: 50mg Analysis time: 3~6min Furnace temperature: 1150 celsius degree Oxygen purity: 99.5% Max power: 3kw Dimensions: 860*530*380mm (sds616 only) Net weight: 80kg Features: Autoloader -- up to 12 samples can be loaded at a time. Ultra-low drift -- only start-up calibration is needed per single workday Fast speed -- 110 seconds per sample Sample introducing rod -- self-protective with long service time Gas supply is based on the position of the sample rod User-friendly windows-based software Options: Computer kit Printer kit. Dimension: 860*530*380mm Weight: 80kg.
Descriptions: SDS212 infrared sulfur analyzer is used to determine the total sulfur content in coal, coke, petroleum and other combustible materials. Conformance with standards: ASTM ISO GB Features: Autoloader -- up to 12 samples can be loaded at a time. Ultra-low drift -- only start-up calibration is needed per single workday Fast speed -- 110 seconds per sample Sample introducing rod -- self-protective with long service time Gas supply is based on the position of the sample rod User-friendly windows-based software Options: Computer kit Printer kit. Dimension:822*604*636mm Weight: 108kg.
FDR-3301 UV fluorescence sulfur analyzer Scope This instrument is a new generation of precision instruments developed in combination with the principle of UV fluorescence measurement and computer technology. It is the most advanced total sulfur analyzer in China. It conforms to ASTM D5453, SH / T 0689 and other standards. The instrument complies with national refined oil Arbitration standard for determination of total sulfur content. It widely used in the determination of crude oil, hydrocarbons and engine fuel, LPG, plastics, petrochemical products, food and so on. The instrument uses the principle of ultraviolet fluorescence measurement, when the sample is introduced into the pyrolysis furnace, the sample undergoes the cracking oxidation reaction, in which the sulfide is quantitatively converted into sulfur dioxide, carried by the carrier gas, the moisture is removed by the membrane dryer, (SO2 *), when the SO2 * return to the steady state of sulfur dioxide emission fluorescence, the release of energy received by the photomultiplier tube, and then amplified by the micro-current amplifier, and then to the SO2 * The amount of sulfur dioxide is proportional to the total sulfur content in the sample, so the total sulfur content in the sample can be determined by measuring the luminous intensity of the sample. Features 1, computer control, it can achieve man-machine dialogue, data and peak shape can be automatically stored and printed. 2, the operating software and LIMIS system can be connected to achieve automatic data transmission. 3, the instrument uses a new quartz cracking tube, which can increase the injection volume, reduce measurement error, improve the sensitivity of the instrument, higher repeatability. 4, cooling fan can automatically turn on and off, so you can save the trouble of waiting for shutdown, saving time and effort. 5, the darkroom system uses the latest technology, the key components of imported detection components to improve the instrument's detection accuracy and sensitivity. 6, the instrument uses imported film dryer to absorb water, eliminating the need to replace the frequent trouble of magnesium perchlorate, while reducing the leakage problem. 7, the instrument uses computer-controlled temperature, improve the accuracy of the instrument temperature control, and difficult to over-temperature. 8, the instrument uses air-cooled instead of water-cooled, saving water resources. 9, the user can retrieve the existing calibration curve, after use the standard sample to calibration it, you can analysis sample. Technical Parameters 1, standards: ASTM D5453, SH/T 0689 and other standards 2, measuring range: 0.2mg / L ~ 10000mg / L ~ percentage 3. Air source: Argon: 99.999%, Oxygen: 99.999% 4, sample status: solid, liquid, gas (with corresponding injector) 5, temperature range: room temperature ~ 1100 ± 3 6, repeatability error: 0.2mg / L X
Features 1, the instrument adopts the automatic tube furnace test method, program control tube furnace heating and moving 2, the instrument adopts the super thermal insulation material, is the tube furnace can work under high temperature 3, the instrument adopts the intelligent control system, with temperature setting, time setting and alarm function detection 4, the instrument uses a timing device, the alarm prompt
Scope UV fluorescence sulfur analyzer is based on UV fluorescence measurement principle and the development of computer technology combined with a new generation of precision instruments, is currently the most advanced of the total sulfur content tester, in line with ASTM D5453, SH / T 0689 and other standards, the instrument is National total sulfur content of refined oil arbitration standards. Now widely used in the determination of total sulfur content of crude oil, hydrocarbons and fuel, petroleum, plastics, petrochemicals, food and so on. Measurement principle instrument uses ultraviolet fluorescence method, when the sample is introduced into the pyrolysis furnace, cracking occurred sample oxidation of sulfide which quantitatively converted to sulfur dioxide, carried by a carrier gas, off which the water through a membrane dryer, into the reaction chamber, sulfur dioxide absorbing ultraviolet light energy into an excited state of sulfur dioxide (SO2 *), the fluorescence emission of sulfur dioxide when SO2 * to return to a stable state, the energy released by a photomultiplier tube to receive, and then the micro-current amplifier, computer data processing, the amount of reaction with sulfur dioxide emission intensity is proportional to the amount of sulfur dioxide and total sulfur content in the sample is proportional, so the content of the sample can be determined by measuring total sulfur emission intensity. Features 1, computer-controlled operation, enabling interactive, data, peak shape can be automatically stored print. 2, the operating software can be connected with LIMIS system, automatic data transmission. 3, the instrument uses the new quartz pyrolysis tube, the injection volume can be increased to reduce measurement errors, increase the sensitivity of the instrument, higher repeatability. 4, cooling fans, automatic switch, eliminating the need to wait for the shutdown to finish samples trouble, saving time and effort. 5, darkroom system uses the latest technology, the key components imported detecting element to improve the detection accuracy and sensitivity of the instrument. 6, equipment imported membrane dryer to absorb , eliminating the need to frequently replace magnesium perchlorate of trouble, while reducing the leakage problem. 7, using computer control of temperature, improve the instrument precision temperature control, and difficult to over-temperature. 8, using air instead of water cooling, saving water resources. 9, can be adjusted to take existing calibration curve calibrated using a standard sample after sample analysis. Technical Parameters 1, in line with standards: ASTM D5453, SH / T 0689 and other standards 2, measuring range: 0.2mg / L ~ 10000mg / L ~ percentage 3. Air source: Argon: 99.999% Oxygen: 99.999% 4, sample status: solid, liquid, gas (with corresponding injector) 5, temperature range: room temperature ~ 1100 ? ± 3 ? 6, repeatability error: 0.2mg / L=X
FDR-3301 UV fluorescence sulfur analyzer Scope UV fluorescence sulfur analyzer is based on UV fluorescence measurement principle and the development of computer technology combined with a new generation of precision instruments, is currently the most advanced of the total sulfur content tester, in line with ASTM D5453, SH / T 0689 and other standards, the instrument is National total sulfur content of refined oil arbitration standards. Now widely used in the determination of total sulfur content of crude oil, hydrocarbons and fuel, petroleum, plastics, petrochemicals, food and so on. Measurement principle instrument uses ultraviolet fluorescence method, when the sample is introduced into the pyrolysis furnace, cracking occurred sample oxidation of sulfide which quantitatively converted to sulfur dioxide, carried by a carrier gas, off which the water through a membrane dryer, into the reaction chamber, sulfur dioxide absorbing ultraviolet light energy into an excited state of sulfur dioxide (SO2 *), the fluorescence emission of sulfur dioxide when SO2 * to return to a stable state, the energy released by a photomultiplier tube to receive, and then the micro-current amplifier, computer data processing, the amount of reaction with sulfur dioxide emission intensity is proportional to the amount of sulfur dioxide and total sulfur content in the sample is proportional, so the content of the sample can be determined by measuring total sulfur emission intensity. Features 1, computer-controlled operation, enabling interactive, data, peak shape can be automatically stored print. 2, the operating software can be connected with LIMIS system, automatic data transmission. 3, the instrument uses the new quartz pyrolysis tube, the injection volume can be increased to reduce measurement errors, increase the sensitivity of the instrument, higher repeatability. 4, cooling fans, automatic switch, eliminating the need to wait for the shutdown to finish samples trouble, saving time and effort. 5, darkroom system uses the latest technology, the key components imported detecting element to improve the detection accuracy and sensitivity of the instrument. Technical Parameters 1, in line with standards: ASTM D5453, SH / T 0689 and other standards 2, measuring range: 0.2mg / L ~ 10000mg / L ~ percentage 3. Air source: Argon: 99.999% Oxygen: 99.999% 4, sample status: solid, liquid, gas (with corresponding injector) 5, temperature range: room temperature ~ 1100 ? ± 3 ? 6, repeatability error: 0.2mg / L=X
Scope Petroleum product sulfur content analyzer (x-ray spectroscopy) is in accordance with people's republic of china standard gb / t11140, gb / t17040, astm d4294 requirements specified in design and manufacture of this instrument for the determination of trace sulfur content of petroleum products. Because it uses physical analysis methods, with fast analysis without complicated sample pretreatment, high precision, human error is small, low labor intensity of operators, no pollution, it has been widely used and generally replace other measuring sulfur in the international arena the analytical method. Features 1, with full english operating system, the man-machine interface friendly exchanges. 2, short detection time, automatic test results within 30 seconds; automatic c / h ratio correction, for a variety of samples; 3, large-screen lcd, automatic print measurement data; 4, using the x-ray tube excitation, the instrument can be long-term use, without affecting the source attenuation; 5, the use of physical methods, the analysis does not touch, do not destroy the sample, no chemical reagents; 6, instrument with integrated design, easy maintenance; Technical parameters 1, the scope of analysis: s analysis range can be adjusted by the calibration curve of the selected method. 2, the scope of analysis width: s% max-s% min=9.999%; such as oil: s: 0.001 ~ 9.999%. 3, the inherent error, accuracy of analysis: such as oil: in line with the national standard gb / t 17040, at the same time meet the relevant requirements of american national standard astm d4294. 4, system analysis time: 1 to 999 seconds, the recommended value of 60 seconds. 5, detection limit: 10ppm 6, using the conditions: ambient temperature: 5 ~ + 40 ?, relative humidity: =85% (30 ?), power supply: 220v ± 20v, 50hz. 7, total power consumption:
FUJI developed the first infrared gas analyzer in Japan to use mass-flow sensors. Since then, we have supplied customers with various types of gas analyzers to support environmental preservation and control efforts. These efforts include measurements of atmospheric pollution and detection of low density of SOx and NOx, generated by incinerating facilities and boilers. FUJI's gas analyzers are widely used to monitor the atmosphere to help maintain a cleaner natural environment.
Scope UV fluorescence sulfur analyzer is based on UV fluorescence measurement principle and the development of computer technology combined with a new generation of precision instruments, is currently the most advanced of the total sulfur content tester, in line with ASTM D5453, SH / T 0689 and other standards, the instrument is National total sulfur content of refined oil arbitration standards. Now widely used in the determination of total sulfur content of crude oil, hydrocarbons and fuel, petroleum, plastics, petrochemicals, food and so on. Measurement principle instrument uses ultraviolet fluorescence method, when the sample is introduced into the pyrolysis furnace, cracking occurred sample oxidation of sulfide which quantitatively converted to sulfur dioxide, carried by a carrier gas, off which the water through a membrane dryer, into the reaction chamber, sulfur dioxide absorbing ultraviolet light energy into an excited state of sulfur dioxide (SO2 *), the fluorescence emission of sulfur dioxide when SO2 * to return to a stable state, the energy released by a photomultiplier tube to receive, and then the micro-current amplifier, computer data processing, the amount of reaction with sulfur dioxide emission intensity is proportional to the amount of sulfur dioxide and total sulfur content in the sample is proportional, so the content of the sample can be determined by measuring total sulfur emission intensity. Features 1, computer-controlled operation, enabling interactive, data, peak shape can be automatically stored print. 2, the operating software can be connected with LIMIS system, automatic data transmission. 3, the instrument uses the new quartz pyrolysis tube, the injection volume can be increased to reduce measurement errors, increase the sensitivity of the instrument, higher repeatability. 4, cooling fans, automatic switch, eliminating the need to wait for the shutdown to finish samples trouble, saving time and effort. 5, darkroom system uses the latest technology, the key components imported detecting element to improve the detection accuracy and sensitivity of the instrument. 6, equipment imported membrane dryer to absorb , eliminating the need to frequently replace magnesium perchlorate of trouble, while reducing the leakage problem. 7, using computer control of temperature, improve the instrument precision temperature control, and difficult to over-temperature. 8, using air instead of water cooling, saving water resources. 9, can be adjusted to take existing calibration curve calibrated using a standard sample after sample analysis. Technical Parameters 1, in line with standards: ASTM D5453, SH / T 0689 and other standards 2, measuring range: 0.2mg / L ~ 10000mg / L ~ percentage 3. Air source: Argon: 99.999% Oxygen: 99.999% 4, sample status: solid, liquid, gas (with corresponding injector) 5, temperature range: room temperature ~ 1100 ? ± 3 ? 6, repeatability error: 0.2mg / L=X
Sulfur Pure sulfur powder or sulfur powder without any mixture. There are many uses for sulfur, including: 1. Skin diseases such as itching, allergies, acne, ringworm, ringworm, eczema, dandruff and other skin diseases caused by bacteria. 2. Beauty: usually used to mix whitening cream cosmetics & other facial & body treatments. 3. Fertilize the soil before planting seeds. 4. Relieve aches, pain and gout by soaking your feet in a mixture of sulfur dissolved in warm water. How to use : 1. Mix sulfur powder with water / lime juice / coconut oil in a 1:1 ratio 2. Stir until mixed evenly 3. Apply to problem areas of the skin / acne / tinea versicolor / itching and other skin diseases 4. Leave it for 15-20 minutes until the sulfur dries so that it works optimally 5. Rinse with water until clean Net: 33 Kg Physical: content 99.8% Meshes : 325 Note: The goods we sell are goods of the best quality grade, packaged with high micron plastic so as to maintain the purity of the goods and sealed so that the chemicals are not damaged and are kept safe from reaching your place.
Sulfur Granular Grade 99.95 & lump as per attached specification Request to send your enquiries for price. Payment terms TT 30:70
I can supply EN 590, in large quantities, low sulfur diesel oil. From 5,000 MT up to 200,000 MT. Interested Buyer may kindly send their LOI to me to enable me to move forward. The rate is $415 to $430 on CIF basis; any safe port in the world. Do contact me at the earliest.
I can supply EN 590, in large quantities, low sulfur diesel oil. From 5,000 MT up to 200,000 MT. Interested Buyer may kindly send their LOI to me to enable me to move forward. The rate is $415 to $430 on CIF basis; any safe port in the world. Do contact me at the earliest.
Pure sulfuric acid does not occur naturally due to its strong affinity to water vapor; it is hygroscopic and readily absorbs water vapor from the air. Concentrated sulfuric acid is highly corrosive towards other materials, from rocks to metals, since it is an oxidant with powerful dehydrating properties. Phosphorus pentoxide is a notable exception in that it is not dehydrated by sulfuric acid but, to the contrary, dehydrates sulfuric acid to sulfur trioxide. Upon addition of sulfuric acid to water, a considerable amount of heat is released; thus, the reverse procedure of adding water to the acid should not be performed since the heat released may boil the solution, spraying droplets of hot acid during the process. Upon contact with body tissue, sulfuric acid can cause severe acidic chemical burns and even secondary thermal burns due to dehydration. Dilute sulfuric acid is substantially less hazardous without the oxidative and dehydrating properties; however, it should still be handled with care for its acidity.
Hydrogen Purity Analyzer: Vasthi Portable Hydrogen Purity Gas Analyzers Model VHP- 200 is a light weight, easy to handle, battery-powered analyzer, used to verify measurements and for spot-checking when other methods provide questionable results.
Hydrogen Purity Analyzer: Vasthi Portable Hydrogen Purity Gas Analyzers Model VHP- 200 is a light weight, easy to handle, battery-powered analyzer, used to verify measurements and for spot-checking when other methods provide questionable results.
Vasthis handheld Flue gas analyzer,Model-VE5400 offers the efficiency of complete combustion optimisation all the way to comprehensive measurement and customer data management.Our Portable flue gas analyzers cover the entire measurement and documentation requirement in process and flue gas testing with instant reading. Vasthiâ??s VEA800 series is an ideal analyzer that measures 5 gases with 4 sensors. User friendly gases selection is implemented in this analyzer. This Portable Flue Gas Analyzer consists unique features.It has in-built crystal-clear touch display which enables user to view concentration values of flue gases and Bluetooth/Wi-Fi connectivity facilities.Using these facilities,Users can download the stored data as well as print it with any printer using Bluetooth / Wi-Fi User can compare daily data with charts & graphs to optimize and increase the combustion efficiency. Measuring Gases SO2,NO,CO2,NO2,Flue Gas Temperature & Temperature combustion air VASTHI will give the gases as per customer required..