A salt spray test chamber is used to test the anti-corrosion quality of all the materials surfaces of painting, coating, electroplating in the condition of salt spray environment. Basic salt spray test chambers meet ASTM, ISO, IEC, and other International Standards test methods, capacity available in 108L, 320L, 410L, 780L, 1000L, 1600L capacity.
2.Technical parameters: 1. Box size in the laboratory: DL-120LA W1200 * D1000 * H500 (mm), Approximate dimensions: 2300 * 1300 * 1400mm, 2 standard temperatures, Laboratory temperature: nss acss 35 ± 1 /pass 50 ± 1 Pressure bucket humidity: nss acss 47 ± 1 /pass 63 ± 1 , Salt water temperature: 35 ± 1 It can be heated without water, 3 volumes, Laboratory capacity: 800L Salt water tank capacity: 40L, 4 compressed air, Compressed air pressure: 1.00 ± 0.01kgf/c 5 spray volume: 1.0-2.0ml/80c /h, 6 spray mode: continuous spray, timed spray, programmable spray, intermittent spray, demisting in the box, 7. Power supply: AC220V 50Hz/20A, 8. Material: The entire PVC board is made, and the salt spray testing machine adopts advanced three-dimensional reinforcement technology internally, with a strong and solid structure that never deforms. 9. Water adding method: An automatic water adding system is adopted, which has the function of automatically replenishing the water level when the water level is insufficient, and the test is not interrupted. 10. Nozzle: Precision glass nozzle, salt spray testing machine used for 4000 hours to ensure no crystal blockage. 11. Protection system: Equipped with dual over temperature protection and insufficient water level warning to ensure safe use. 12. Temperature controller: digital display, PID control, high stability platinum temperature probe, error 0.3 13. Heating method: The laboratory adopts direct steam heating method, which increases the temperature quickly and shortens the standby time of the salt spray testing machine. 14. The spray tower is equipped with two conical dispersers, which have the functions of guiding fog, adjusting fog volume, and even fog falling. 15. The pressure bucket adopts Henry's law to heat and humidify, and provide the humidity required by the salt spray testing machine laboratory. 16. Opening method: Pneumatic automatic opening is adopted, The salt spray testing machine is one of the "three prevention" (humid heat, salt spray, mold) testing equipment for artificial climate environments. It is an important salt spray testing equipment for studying the adaptability and reliability of various environments in industries such as machinery, national defense, light industry, electronics, light industry electronics, and instruments. This salt spray testing machine can perform neutral salt spray tests in accordance with GB/T2423.17 "Basic Environmental Testing Regulations for Electronic and Electrical Products - Test Ka: Salt Spray Test Method", and can also perform acetate spray tests. This salt spray tester complies with CNS, ASTM, JIS and ISO standards. The salt spray test is to test the corrosion resistance of the products after coating, electroplating, Anodizing, anti-rust oil and other anti-corrosion treatments on the surfaces of various materials.
Precision salt spray corrosion test chamber Technical Specifications: Model AUT0-60 Auto-90 Auto-120 Inner Box Size W*D*H(mm) 600*450*400 900*600*500 1200*800*500 Outside Box Size W*D*H (mm) 1070*580*1030 1380*800*1150 1700*950*1210 Power 220V,1.5KW ,50HZ 220V,1.5KW ,50HZ 220V,3KW,50HZ Testing capacity 108L 270L 480L Brine Tank Volume 10L 15L 20L Reference standards CNS:3627,3385,4159,7669,8886; JIS:D0201,H8502, H8610,K5400,Z2371; ISO: 3768,3769,3770; ASTM: 8117,B268 Technical Features: Box material : Local temperature and humidity inside and outside the box are used for A-level gray high-corrosive PVC, for salt spray, copper acetate, and other test specifications Test. Saturation pressure barrel : It uses the A-level German imports of gray PVC material. Laboratory Racks: It uses sophisticated Class A gray PVC material designed "V" shape long, products tested by the 15 ¡ã -30 ¡ã angle be adjusted. Laboratory cover:It uses a 5mm thick transparent imported high toughness PVC board, bending method designed to cover 100 degree ridge-type transparent. With power failure memory function of time, so after the original call time to complete the remaining time of the experimental work, with a double over-temperature protection, water shortage warning, ensure safety. Technical basis:According to JIS, ASTM, CNS, GB standard parameter setting operation. Standard Laboratory Air pressure barrel Salt spray test NSS ,ACSS 35¡ãC¡¨¤1¡ãC 47¡ãC¡¨¤1¡ãC Corrosion test CASS 50¡ãC¡¨¤1¡ãC 63¡ãC¡¨¤1¡ãC Systems: •Heating system It uses steam heating, heating speed, reduce the standby time, when the temperature reached, the thermostat automatically switches the state, the temperature accuracy, less power consumption •Control system High-precision temperature controller, Japan OML timer to control the time, the overall temperature error of ¡¨¤ 1¡ãc. Packed with strong wooden case
Cyclic corrosion test chamber exposes sample to a series of different environments in repetitive cycles that incorporate temperature, humidity, salt spray, and dry. SC series corrosion chambers are upgrade to programmable controller and Ethernet access.
Salt corrosion spray test chamber Configured for your specific tests Alternate Salt Corrosion Spray Test Chamber Grande makes rain and spray testing easier by offering a standard chamber capable of published and OEM proprietary test methods. The standardized design can be configured for the rain/spray tests you need, eliminating the guesswork in buying a chamber. The system is based on the specification requirements, and can also accomplish individual automakers tests, as well as electrical-enclosure tests. Our Design Grande's modular design allows you to add on additional features, depending on the number and type of tests required. One possible choice is to integrate the spray system with a regular temperature and humidity chamber to save money and floor space, while also creating an opportunity to simulate actual operating conditions your product may experience. Our system uses multiple control solenoids to vary the water's spray volume/pressure. A holding tank prepares the water to the desired temperature, if required. A pump ensures the water is delivered in the proper pressure range. The water is fed to a motorized manifold that rotates the spray arms. Each spray arm has an adjustable valve to allow finer control of the spray. Testing capabilities The specification is modeled after and doesnt differ greatly. Details about the nozzle types and the rotating nature of the spray arms and product table are also included in the requirements. Additionally, drip and car wash tests are also specified. Heavy splash/shower S1 Spray room temperature water with 40 nozzles at 14.2 psi (1 kgf/cm2) for 30 minutes. The flow rate of the water shall be 6.5 gallons/min. (24.5 L/m). S2 Spray room temperature water with 40 nozzles at 42.7 psi (3 kgf/cm2) for 60 minutes. The flow rate of the water shall be 10.3 gallons/min. (39.2 L/m). Light spray/rain R1 Spray room temperature water with two nozzles at 4.3 psi (0.3 kgf/cm2) for 10 minutes. The flow rate of the water shall be 0.8 gallons/min. (3.2 L/m). R2 Spray room temperature water with two nozzles at 1.4 psi (0.1 kgf/cm2) for 10 minutes. The flow rate of the water shall be 0.5 gallons/min. (1.9 L/m). Examples of OEM automotive manufacturers' requirements Heat the sample to a temperature above boiling, then spray with cold water for about two minutes. Repeat cycle. Heat the sample to boiling temperature, then spray with room temperature water for about fifteen minutes. Repeat cycle. Simulate a car wash by using high pressure spray. Features Rotating rain and spray nozzles designed to JIS specifications Speed control for the rotating spray nozzles Stationary product shelf - A rotating shelf is optional: see options Water pressure regulators, gauges and flow meters Special high-volume floor drain system to rapidly drain water out of the chamber Interior chamber size is the smallest possible area using the JIS specified nozzles Applicable Test Methods
Alternate salt corrosion spray test chamber Salt Corrosion Spray Test Chamber Salt Spray Test Chamber Configured for your specific tests Alternate salt corrosion spray test chamber adds below functions from traditional salt corrosion spray test chamber:Programmable controllers,accelerated test for copper and acid test.,etc.It complies with Standard of ASTMDIN IEC GJB. Grande makes rain and spray testing easier by offering a standard chamber capable of published and OEM proprietary test methods. The standardized design can be configured for the rain/spray tests you need, eliminating the guesswork in buying a chamber. The system is based on the specification requirements, and can also accomplish individual automakers tests, as well as electrical-enclosure tests. Our Design Grande's modular design allows you to add on additional features, depending on the number and type of tests required. One possible choice is to integrate the spray system with a regular temperature and humidity chamber to save money and floor space, while also creating an opportunity to simulate actual operating conditions your product may experience. Our system uses multiple control solenoids to vary the water's spray volume/pressure. A holding tank prepares the water to the desired temperature, if required. A pump ensures the water is delivered in the proper pressure range. The water is fed to a motorized manifold that rotates the spray arms. Each spray arm has an adjustable valve to allow finer control of the spray. Testing capabilities The specification is modeled after and doesn�??t differ greatly. Details about the nozzle types and the rotating nature of the spray arms and product table are also included in the requirements. Additionally, drip and car wash tests are also specified. Heavy splash/shower S1 Spray room temperature water with 40 nozzles at 14.2 psi (1 kgf/cm2) for 30 minutes. The flow rate of the water shall be 6.5 gallons/min. (24.5 L/m). S2 Spray room temperature water with 40 nozzles at 42.7 psi (3 kgf/cm2) for 60 minutes. The flow rate of the water shall be 10.3 gallons/min. (39.2 L/m). Light spray/rain R1 Spray room temperature water with two nozzles at 4.3 psi (0.3 kgf/cm2) for 10 minutes. The flow rate of the water shall be 0.8 gallons/min. (3.2 L/m). R2 Spray room temperature water with two nozzles at 1.4 psi (0.1 kgf/cm2) for 10 minutes. The flow rate of the water shall be 0.5 gallons/min. (1.9 L/m). Examples of OEM automotive manufacturers' requirements Heat the sample to a temperature above boiling, then spray with cold water for about two minutes. Repeat cycle. Heat the sample to boiling temperature, then spray with room temperature water for about fifteen minutes. Repeat cycle. Simulate a car wash by using high pressure spray.
Envisys manufacture and supply standard range of salt spray corrosion test chambers. We provide cyclic corrosion chamber in different versions, mini, mid-range, & walk-in range salt spray chamber for simulating salt mist (fog) conditions to check corrosion resistance testing of materials & surface coatings
Salt spray test chamber is applicable for the salt spray corrosive test for the protected layer of components, parts, electronic and electrical parts and metal materials and industrial products. Salt spray test chamber can be supplied in two versions the basic salt spray chamber and the cyclic corrosion test chamber cct as applicable for the customers testing and will meet all of the most stringent test requirements.
SALT SPRAY CORROSION TEST CHAMBERS AVAILABLE IN VARIOUS SIZES 10 CU.FT, 21 CU FT, 32 CU.FT, 53 CU.FT ETC MEETING THE CORROSION TEST REQUIREMENT AS PER INTERNATIONAL STANDARDS VIZ., ASTM, JIS, DIN, JSS ETC.,
YWX/Q-010 Standard Salt Spray Corrosion Test Chamber is According to IEC 60068-2-11 Introduction: YWX/Q-010 Salt Spray Test Equipment is applicable to the salt spray corrosive test for the protection layer of components, parts, electronic and electrical parts and metal materials and industrial products. Model Work Room Size (mm) Exterior Size (mm) Voltage Power (KW) YWX/Q-150 450X600X400 800x1070x1050 AC220 2.5 YWX/Q-250 600x900x500 870x1400x1150 AC220 3.5 YWX/Q-750 750x1100x500 1030x1680x1260 AC220 4.5 YWX/Q-010 850x1300x600 1160x2000x1390 AC380 6.5 YWX/Q-016 850x1600x600 1280x2320x1500 AC380 9.5 YWX/Q-020 900x2000x600 1220x2530x1410 AC380 11 wooden
Environmental test chambers, climatic chambers, salt spray chambers, corrosion test chambers, altitude chambers, dry heat chambers, ovens, rain test chambers, dust test chambers, deep freezers, stability chambers.
Focus-6200 products are kind of non-hardening and self-adhesive waterproof sealing butyl tapes. The materials are weathering resistance and fully accommodate to the surface that it attached to, with effective life up to 20 years. Main Specification (Customized size is acceptable.) 2mm thickness * 20mm width * 20mm roll length 2mm thickness * 30mm width *20mm roll length Main Color - black, grey, white Technical Data Product Series FOCUS-6200 Series Application Construction Industry Elongation - 500% Heat Resistance 90, no flowing within 2h Low Temperature Flexibility 40, no crack on surface within 24h Peel Strength 25N/cm Tensile Strength 250KPa Anti UV non-hardening and no cracks within in 2000h Corrosivity Non-corrosive to galvanizedsheet, aluminum sheet and coppersheet Advantages * Never hardening, maintain good waterproofing property with weathering resistance performance. * Excellent performance in waterproofing and sealing. * Good anti-aging performance effective life up to 20years. * Easy to apply. Applications * Provide waterproof and sealing protection forsteel structure construction. * Provide waterproof and sealing protection for door joints, window joints,roofs and air-ducts. Provide waterproof and sealing protection for sunshine rooms, light plate rooms and thermostatic chamber. * Provide repair function for leaks on surfaces of metal/plastic/glass/concrete.
Micro Silica Sand: Micro silica also known as fume, is an amorphous (non-crystalline) polymorph of silicon dioxide, silica. It is an ultrafine powder collected as a by-product of the silicon and ferrosilicon alloy production and consists of spherical particles with an average particle diameter of 150 mm. The main field of application is as pozzolanic for high performance concrete because of its extreme fineness and high silica. Applications : Silica is added to Portland cement concrete to improve its properties, in particular its compressive strength, bond strength, and abrasion resistance. These improvements stem from both the mechanical improvements resulting from addition of a very fine powder to the cement paste mix as well as from the pozzolanic reactions between the silica fume and free calcium hydroxide in the paste. Advantages : Addition of silica also reduces the permeability of concrete to chloride ions, which protects the reinforcing steel of concrete from corrosion, especially in chloride-rich environments such as coastal regions and those of humid continental roadways and runways (because of the use of deicing salts) and saltwater bridges.
Commodity : Potassium sorbate Molecular formula : C6H7KO2 Molecule Weight : 15022 HS code : 29161900 CAS : 24634615� Specifications appearance : White crystal granule Production Standard : FCCIV Content : 9801010 K2CO3 : 1 max Loss on drying : 1 max Chloride : 001 max Heavy metalsas : Pb 0001 max Packing in carton 25kgs net weight Quantity 14MT loaded into 1 x 20GP Excellent preservative properitesproperites Sorbic Acid Potassium Sorbate can restrain effectively the activity of mould yeast and aerophile bateria Restrain growth and reproduction of the pernicious micro organism as pseudomonas staphylococcus salmonella action to restrain growth is more powerful than killing Meanwhile it can not restrain useful microoranganim growth ad Anaerobicbearing barilli acidophil therefore to lengthen food store peroid and remain food original flavor The preservative efficiency of sorbic acid Potassium sorbate is 510 times sodium benzoate High safety Sorbic Acid Potassium Sorbate is one kind of nonsuturated fatty acid compounds It can be absorbed by human body rapidly then decomposed into CO2 and H2Omoreover no remaining in body ADI 025mgkg based on sorbic acid FAOWHO 1994 LD50 4920 mgkglarge mouse by mouth GRASFDA 1823640 1994 Its toxicity only 112 times table salts and 140 times sodium benzoate Good stability Sorbic Acid Potassium Sorbate is stable in sealed staus will not be decomposed until 270C It will be oxidized into colored ones and absorbing moisture in case exposed in air for a long time Wide application At the momentSorbic Acid Potassium Sorbate has been used extensively in food drinkvegetables in soy tabacco drugs cosmetics agricultural products forage and other domain Its applicaion should be wide and wide in the world As acidic preservative Sorbic Acid Potassium Sorbate is also used well in neutral foodph6065 The preservative efficiency of sodium benzoate will decrease clearly and have a bed taste while ph4 Applicaion flexibilitySorbic Acid Potassium Sorbate can be used by direct adding sprayingretting dry spraying using in packing material and other method
Commodity: Potassium Amyl Xanthate Product Nature Chemical name: Potassium Amyl Xanthate (PAX) Equivalent to : Z-6, AERO 350 xanthate Molecular Formula: C5H11OCSSK Physical characteristics: Slight yellow or grey yellow free flowing Powder or pellet and soluble in water. It is a xanthate based on the C5 alkyl isoamyl alcohol in the potassium salt form Testing method: Lead acetate titration CAS Number: 2720-73-2 EINECS No.: 213-180-2 Use A Collector With High Collection And Normal Selectivity,widely Use In Floatation Of CU/PB/NE AND PYRITE, Especially For The Floatation Of The Gold In Gold And Copper Mine.it Could Make Good Result In Copper And Lead Oxidized Ore.ofeen Used In Rough Selecting And Scavenging. Specifications Chemical components Specification 1 Specification 2 Purity 85% Min 90% Min Moisture & volatiles 10% Max 4% Max Free alkali 0.5% Max 0.2% Max Packing and Storage 120KG IRON DRUM,134 DRUMS PER 20'FCL,16.08MT; (OR 110-180KG IRON DRUM) 850KG Wooden Box,20 Box Per 20'fcl,17mt; (or 500kg,800kg,850kg Wooden Box With Inner BAG) 25-50KG WOVEN BAG
Commodity: Sodium Hydrosulfite Other name: Synonyms: Sodium Hydrosulphite; Sodium Dithionite; Dithionous acid, Disodium salt; Sodium Sulfoxylate CAS No.: 7775-14-6 Molecular Weight: 174.10 Chemical Formula: Na2S2O4 Product Description Appearance: White, crystalline powder. Product Feature Odor: Slight irritative. Specific Gravity: Unavailable Solubility: Soluble in water. Density: 2.19 pH: 6-7 pH Test-Method: PH test paper. % Volatiles by volume @ 21C (70F): 0 Boiling Point: Not applicable. Melting Point: >300 C Decomposes. Vapor Pressure (mm Hg): No information found. Bulk Density: ~0.9 Evaporation Rate (BuAc=1): No information found. Application 1. Widely used in textile industry for vat dyeing, reduction cleaning, printing and stripping, textile textile bleaching . 2. bleaching paper pulps , especially mechanical pulps, its the most fittable bleaching agent in pulps. 3. bleaching kaolin clay, fur bleaching and reductive whitening, bleaching of bamboo products and straw products, 4. in mineral, the compound of thiourea and other sulphides. 5. as reducing agent in chemical industry. 6. Sodium hydrosulfite food additive grade is used in foodstuffs, as bleaching agent and preservative dried fruits, dried vegetable, vermicelli, glucose, sugar, rock sugar, caramel, candy, liquid glucose, bamboo shoots, mushrooms and canned mushrooms. Packaging 50kg/100kg net in iron drums with double PVC bags Product Specification/Models NDEX 90%, 88%, 85%. FOOD ADDITIVE Na2S2O4, 90%, 88%, 85%, Fe 20ppm ZincZnOther heavy metal calculated as Pb, 1ppm Water Insolubles05% Shelf Life(month)12
Product Nature Chemical name:Potassium Amyl Xanthate (PAX) Equivalent to : Z-6, AERO 350 xanthate Molecular Formula: C5H11OCSSK Physical characteristics: Slight yellow or grey yellow free flowing Powder or pellet and soluble in water. It is a xanthate based on the C5 alkyl isoamyl alcohol in the potassium salt form Testing method: Lead acetate titration CAS Number: 2720-73-2 EINECS No.: 213-180-2 Use A Collector With High Collection And Normal Selectivity,widely Use In Floatation Of Cu/pb/ne And Pyrite,especially For The Floatation Of The Gold In Gold And Copper Mine.It Could Make Good Result In Copper And Lead Oxidized Ore.Ofeen Used In Rough Selecting And Scavenging. Specifications Chemical components Specification 1 Specification 2 Purity 85% Min 90% Min Moisture & volatiles 10% Max 4% Max Free alkali 0.5% Max 0.2% Max Packing and Storage 120kg Iron Drum,134 Drums Per 20'fcl,16.08mt; (or 110-180kg Iron Drum) 850kg Wooden Box,20 Box Per 20'fcl,17mt; (or 500kg,800kg,850kg Wooden Box With Inner Bag) 25-50kg Woven Bag
This is chemical setting Furan based chemical resistant mortar which is combination of Liquid and Powder, when mixed in proper proportion from workable mortar which after setting and curing give of liquid and give black highly cross linked composites. Furan When set and cured is resistant to highly corrosive acids, alkalis and to powerful organic solvents such as ketones, Aromatic and Chlorinated solvents. It has extreme resistant to Acidic & alkalis, Salts, Greases and Detergents. It resists to Organic & Inorganic acids at their boiling temperature. It is suitable against mild chlorine Gas (dry) phosphorous trichloride, pyridine at room temperature. Furan is especially useful where resistance to mixed media such as aqueous acids /alkalis and organic solvents is needed in chemical plant process and waste streams. Carbon filled Furan is used against corrosive effect of hydrofluoric acid & its salts. PREPARATION OF FURANE MORTAR : Mortar consist of Furan solution and Furan powder. The average mixing ratio necessary to obtain mortar with good working consistency is 1 part by weight Solution & 3 part by weight powder. The ratio will vary slightly depending on temperature and working conditions.Stir the liquid thoroughly before using. Place liquid in a suitable shallow mixing pan. Add powder by weight in the solution mix thoroughly and rapidly until all lumps are dispersed and the mortar is completely homogenous. Spread out the mortar in a thin layer, not more than ¾ thick, to dissipate the heat of reaction and lengthen the working life. Batch size can be varied depending upon the temperature and the speed with which the masons are working. Very large batches will become stiff quite rapidly. Make sure that all the Furan Motrar is used from the pan before another batch is mixed.When working at temperature above 40 C, very small batches not more than 2 Kgs, should be prepared. When working at temperature below 15C the liquid should be kept warm.
METHOD OF APPICATION: * Mastic compound application consist of two coats of. Primer ,Primer and followed by Mastic compound in recommended thickness, ranging from min. 12mm to 25mm in one or two layers to achieve desired thickness without any pin hole and crack. 1). Surface preparation and application of Primer: Refer application method of Primer. 2). After doing necessary surface preparation and application of primer coating, area to be installed with Mastic compound should be divided in to equal no. bays. To maintain even thickness required, place wooden or aluminum batten. Mastic compound is then broken in small pieces and put it in heating pan. While heating, keep material moving to avoid burning. It is heated until it comes in a uniform consistency and then applied on the surface and works it with wooden float, to achieve uniform thickness and smooth surface free from any pinholes. CHEMICAL RESISTANCE PROPERTIES: * Mastic compound has good resistance to weak, diluted acids, alkalis salts etc. It is not recommended to use against strong acids, oxidizing acid solvents, oil and fats STORAGE & PACKING: * Keep Mastic compound away from direct sunlight, heat solvents etc. Under this condition, its shelf life is unlimited. It is supplied in cake form and approx. wt. is 10 kgs. HEALTH & SAFETY: * Handle melted Mastic compound compound very carefully . Avoid contact with skin. It is advisable to wear protective wears at the time of use of Mastic compound and all other our products. This information, given in good faith, is based on results gained from experience and tests. However, all recommendations or suggestions are made without guarantee since the conditions of use are beyond our control.
High Quality Salt Manufacturers in Gandhidham Salt is consumed in various forms since ancient times whole over the world. Nilkanth exports is one of the leading Salt Manufacturers In Gandhidham for Edible grade salt. We manufacture and export Edible grades like Sea Salt/Raw Salt, Crystal Salt, Oversize Salt, Free Flow Iodised Salt, Double Refined Salt and Triple Refined Salt. Moreover, this Our Salt is thoroughly tested by our quality controllers on respective counts of taste, quality, purity, and packaging.