Features: 1. Pressure ranges: 0~10, ..., 0~3000 bar 2. Output signals: 4~20 ma, 0~5 v or 0~10 v 3. High precision: up to 0.05%fso (applicable for range >16barg) 4. Temperature coefficients of zero & span: 0.005%fso 5. Flush membrane available for pressure range > 16 barg 6. Integrated design for 100% pressure seal, no o-ring built in its body 7. Materials: 304 ss (housing); 17-4ph (wetted parts) Oem inner box and carton
Features: 1. Pressure ranges: 0~10, ..., 0~3000 bar 2. Output signals: 4~20 ma, 0~5 v or 0~10 v 3. High precision: up to 0.05%fso (applicable for range >16barg) 4. Temperature coefficients of zero & span: 0.005%fso 5. Flush membrane available for pressure range > 16 barg 6. Integrated design for 100% pressure seal, no o-ring built in its body 7. Materials: 304 ss (housing); 17-4ph (wetted parts) Oem inner box and carton
Product Range Design Code ASME Section VIII, Div I, PD 5500, AD Merkblatter, PED 97/23/EC, IS 2825 or any other international standard. Capacity Upto 500 M3 ( 5,00,000 Liters water volume) Diameter Upto 6 meters Shell & Dished End Thickness Upto 100 mm or more Weight Upto 250 tons Length Upto 60 meters, with suitable field joints. Material of Construction Carbon Steel, LTCS, NACE & HIC resistant Material, Low Alloy Steel for high temperature service (SA 387 Gr 11 and Gr 22), Cladded Steel (CS with SS, Cupronickel, Aluminum Nickel Bronze, Aluminum brass, Titanium, Inconel and many more), SS (300 & 400 series), Duplex & Super Duplex stainless steel, Cupronickel, Monel , Inconel, Nickel & Nickel Alloys, Hastelloy, Titanium, Aluminum & Aluminum alloys.
Gas heating cooking pot pan,oil/electrical heating central kitchen cooking pan pot machine . Gas/oil/Electric cooking pot pan Can heating by Electric, gas, oil heating function, different diameter, with cover, without cover Stainless steel ,automatic mixing/stiring ,Automatic dumping,save labor ,sanitary ,high efficient ! Welcome order ,good price good quality !
1. Current overload or line surge shutdown 2. High temperature compressor shutdown. 3. High pressure alarm shutdown. 4. Low pressure alarm shutdown. 5. Low oxygen cocentrator alarm. Oxygen concentrator: 0.5-5L/min Purity: 95%+_3% Working system Continuous Power Supply AC230V.50Hz/AC220V.60HZ AC120V.60Hz Power: 390VA Net Weight: 16kg( Gross weight: 18.5kgs) Warranty: Long-life compressor designed for 1000 hours of maintenance-free use. Size: 33*26*54cm
Cutter, syringe, strips, needles, thermometer, cannula, glucometer, harmonic focus shears, ace circulation, adhesive mini wrap, blades, blood collection tube, blood pressure monitor, nutella, onion, dried apricot, bioderma, sensibio.
Specifications: Latex free cuff with stethoscope free Adjustable zero position, Euro-type non-stop pin gauge, High Precision, Cuff size: 22-32 cm QUICK, ACCURATE AND EASY TO USE â?? Clinically Validated & most often used by health professionals, still the most reliable and accurate No batteries required Ultra soft washable cotton cover of safety Super Deluxe Aneriod Blood Pressure Apparatus is a compact and functional tool for practicing or employed medical professionals and individuals who need to keep track of their blood pressure on a regular basis The cuff and bellows are very easy to use and are made out of quality materials designed to last a very long time despite regular use. The cuff is designed to facilitate an easy grip, which ensures you donâ??t have to adjust with any discomfort. Blood Pressure is a measurement of the pressure of the blood flowing against the walls of the arteries. Arterial blood pressure is constantlychanging during the course of the cardicac cycle. The highest pressure in the cycle is called the systollic blood pressure.
Pressure Transmitter for Sandvik LH307/LH410
Notice 1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse. 2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface. 3. The wiring should be strictly in accordance with the instructions of our company. 4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument. 5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds. 6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct. 7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse. 8.The quality assurance period is 12 months. Intelligent Operation Method 1. LCD shows the output percentage or process pressure. Press the S key to select the display percentage or pressure.Press Z key to select pressure unit KPa or Mpa when displaying pressure. 2. Press S+Z key for 8 seconds, then release it at the same time, press Z key to set the zero value; Press the S key set the range. note: this function can only be triggered once an operation. 3. Adjustments to zeros or ranges may cause changes in the displayed options, i.e.The percentage being displayed becomes pressure or KPa becomes Mpa, etc. All these changes are shown only in the display, and have no effect on the internal parameters of the transmitter, pressure detection and current output. After adjusting the zero point and range, the S and Z keys can be used to select the desired percentage or pressure. 4. Zero-setting in field pressure-free state: 30 seconds after pressing S+Z key, the display shows zero time at the same time release the two keys, that is, zero. Simulated operation method 1.Zero-setting in pressure-free condition: The potentiometer with the word "zero" on the circuit board is adjusted to zero when it is displayed on the spot.(Note: Clockwise increase, counterclockwise decrease) 2.The potentiometer marked "range" on the circuit board can not be adjusted without standard pressure, so as to avoid the disorder of measurement range.
General Description The series of pressure transducers use imported high-quality pressure sensors and special integrated modules, through fine temperature, zero, full range, and non-linear compensation to achieve accurate measurement and transmission of pressure changes in liquid, gas, steam and other media. Technical Index Measuring medium: liquid, gas, steam Pressure range: -0.1MPA~0~60MPA Accuracy grade: ±0.2%FS, ±0.5%FS Stability: â?¤0.2%FS/year Temperature drift: â?¤0.02%FS/(range 0~70) Environment temperature: -20+85 Storage temperature: -20+85 Output signal: 4-20mA or 1-5VDC Supply voltage: 12-40VDC Allow overload: two times the quota voltage Explosiveproof grade: intrinsically safeia II C T6 flameproof dII C T6 Wetware material: 316 stainless steel and 1Gr18Ni9Ti Shell material: die casting alloy aluminum,surface epoxy spraying Pressure interface: M20X1.5 Weight: ordinary 0.75kg, with on-site instructions 1kg Structure Type x1 Connection x2x31 x4 The link mode and output signal of the compact tranmitter are as follows: Two-wire system: 1 Positive power supply 2 Negative power supply 3 Empty 4 Shell Three wire system: 1 positive power supply 2 Negative power supply (Negative sharing with signals) 3 Signal+ 4 Shell x5 The connection mode of aviation plug transmitter is as follows: Two-wire system(direct outlet type) 1 Red wire connection positive power supply 2 Black wire connection negative power supply Notice 1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse. 2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface. 3. The wiring should be strictly in accordance with the instructions of our company. 4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument. 5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds. 6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct. 7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse. 8.The quality assurance period is 12 months.