Video/radio signal surge protective device is designed according to the IEC standard and national standard. It can be used for single BNC terminal, 16 BNC terminals, F terminal and N terminal lightning protection. This product is suitable for the monitoring system BNC terminal, matrix BNC terminal, optical transceiver BNC terminal, video camera BNC terminal as lightning surge protection. This product is produced according to the discharging, clamping, filtering principles, that realized high efficient discharging lightning currents and resistance of EMP shock which caused by lightning currents. It has advantages of multi classesâ?? protection, extremely low residual voltage, perfect transmission performance, quick respond, large discharging capacity, simple installation and connection, easy maintenance. DK Company can produce this product with different classes working voltage and various number of terminals according to the customer requirement. The 8/20us maximum discharging currents (Imax) can reach 10kA.
Video signal arrestor Applications: Designed for monitor device not to be spoiled by lightning over-voltage, induced over-voltage and static discharge. Video camera E1, pdh, sdh, spdh Digital hard disk video cassette recorder Industrial control Features: Multi. Protection circuits, gas-tube+ tvs technology Dual protection in common module and different module Tvs array technology, low capacitance Multi-strike capability Specifications: Type d12bf d12bf-4d12bf-16 Electrical specifications Impedance75++ Max operating voltage12v Nominal discharge current (8/20++s)3ka Max. Discharge current (8/20++s)5ka Protection level (3ka 8/20++s) Line to line40v Line to pe160v Adapt transmission rate100mbps Insertion lossf 0.5db Response time f 5ns Mechanical specifications Connectorbnc female to malebnc female to female Number of protection ports1416 Diamension (mm)82.7*25*25130*73*25 481*84*47 Working environments Operating temperature minimum-40 Operating temperature maximum85 Operating humidity95%
DK-40 power supply series modular surge protective device(SPD) is designed according to IEC61643 standard. It is accordance with the criterion of Low-voltage Surge Protective Devices-Part 1: Surge Protective Devices Performance Requirements and Test Method of Low-voltage Power Distribution System. With good sealing, it is designed as module and 35mm din-rail mounting. With working indication window, temperature control circuit breaker and built-in over-current protective� circuit, this SPD can release automatically to avoid fire danger when it breaks down. With remote alarm connector, it is convenient for remote monitoring. The main module and the base are replaceable. The lightning protection modes is L-PE, N-PE (2P/4P) or L-N-PE (1+1P) / (3+1P).
2p 20kA single phase surge protector This surge protective device( hereinafter referred to as SPD) are suitable for AC 50/60Hz, rated voltage up to 380v IT,TT,TN-C, TN-S,TN-C-S and other power supply system, it protect to indirect and direct lightning effect or other transient over voltage SPD design according with GB18802.1/IEC61643-1 standard. Specification details: Model PQ3-20 Poles 2P Max. continious working voltage(Uc) 420V AC(can customized) Nominal discharge current(In) 10kA Max.discharge current(In) 20kA Voltage protection level(Up) 1.5kV Matched circuit breaker/Fuse 32A Response time
4p 20kA three phase surge protector This surge protective device( hereinafter referred to as SPD) are suitable for AC 50/60Hz, rated voltage up to 380v IT,TT,TN-C, TN-S,TN-C-S and other power supply system, it protect to indirect and direct lightning effect or other transient over voltage SPD design according with GB18802.1/IEC61643-1 standard. Specification details: Model PQ3-20 Poles 4P Max. continious working voltage(Uc) 420V AC(can customized) Nominal discharge current(In) 10kA Max.discharge current(In) 20kA Voltage protection level(Up) 1.5kV Matched circuit breaker/Fuse 32A Response time
If the surge arrestor is out of service, it causes short circuit in the system. When surge arrestor separator is not used, this short circuit cause the activation of the circuit breaker and blackout of the energy of the system. Surge Arrestor separator prevents energy blackout by cutting grounding connection of the surge arrestor that is out of service. Activation of the surge arrestor separator, in other words cutting the grounding connection means that the Surge Arrestor has lost its function and must be replaced. Structure and Mode of Operation; When the surge arrestor loses its function, separator responds quickly to the current flow on it. Voltage decreases on the resistances of the separator and the capsule explodes by means of the arc occurring in the small opening inside of it and separates grounding connection of the surge arrestor.
* 1P, 2P, 3P, 4P optional * Uc: 420V * In: 10KA * Imax: 20KA * Customized available
DK-nDCt/RJ45 series network signal surge protective device(SPD) is designed according to IEC61312 standard. It is suitable for lightning protection of computer, switch and other network equipment. With features of integration metal structural design, high discharge capacity and fast response, it can ensure the equipment to work properly.
Atmospheric events and on-off surges in the system cause formation of extreme voltages in electricity networks. ELOPAR surge ARRESTORS are designed to protect distribution transformers, engines, work machines and medium voltage cables against extreme voltages in the best way. Advantages of Elopar Polymer Surge Arrestors are; - Low Protection level - No danger of explosion - Long protection distance- High energy input capacity Resistant to aging - Stable characteristics - Polymer housing- Resistant to contamination - Safe assembly- Maintenance-free - High support resistance- Easy to use - Creeping distance is over 25 mm/kV- Light Structure and Mode of Operation; Metal oxide surge arrestors do not contain gaps but contain metal oxide blocks that are placed into a polymer body impermeably. These blocks carry variable resistance feature. In other words, they become conductive as the voltage rises. In case of temporary over voltage, current flows over surge arrestor so that such devices or cables are protected. These surge arrestors not only have a very good mechanical strength, but also have very good dielectrically smoothness in all surfaces. Furthermore, they have high resistance against contamination arising from atmospheric conditions under the heaviest operating conditions. ELOPAR Polymer Surge Arrestors are manufactured according to TS EN 60099-4 (IEC 60099-4) standard in order to perform this task in the best way. Type tests have been performed at ICMET CRAIOVA High Power Laboratory and it has passed from all tests successfully. - Surge arrestors must be as close as possible to the device to be protected. - Surge Arrestor grounding must be the same with the system grounding
Atmospheric events and on-off surges in the system cause formation of extreme voltages in electricity networks. ELOPAR surge arrestors are designed to protect distribution transformers, engines, work machines and medium voltage cables against extreme voltages in the best way. Elopar Metal Oxide Surge Arrestors; - have low protection level- High energy input capacity - High protection distance- Stable characteristics - are resistant to aging- Resistant to contamination - have porcelain body- Maintenance-free - safely installed- easy to use - Creeping distance is over 25 mm/kV- High support resistance Structure and Mode of Operation; Metal oxide surge arrestors do not contain gaps but contain metal oxide blocks that are placed one on another in a porcelain body. These blocks have variable resistance characteristics. In other words, they become conductive as the voltage rises. In case of temporary over voltage, current flows over surge arrestor so that such devices or cables are protected. These surge arrestors not only have a very good mechanical strength, but also have very good dielectrically smoothness in all surfaces. Furthermore, they have high resistance against contamination arising from atmospheric conditions under the heaviest operating conditions. ELOPAR Porcelain Body Surge Arrestors are manufactured according to TS EN 60099-4 (IEC 60099-4) standard in order to perform this task in the best way. Type tests have been performed at ICMET CRAIOVA High Power Laboratory and it has passed from all tests successfully. - Surge arrestors must be as close as possible to the device to be protected. - Surge Arrestor grounding must be the same with the system grounding.
Maximum continuous running voltage(uc) 70v Maximum discharge current (imax 8/20us) 20ka Limit voltage ¡ü200v Insertion loss ¡ü0.2db Contact type: n Working temperature&humidity: -40¡æ~85¡æ, ¡ü95% Install method: series connection Color : aluminium/silver Protection degree: ip20 Standard package
Ac power arrester surge protector Applications: C/d class surge protective device for ac power system. Sensitive electronic equipment Telecom centers Automatic control centers Intelligent mansions Industrial enterprises Medical institutes Features: Din rail mounting for easy installation Plug connectors for quick and easy connection or rewiring 40ka maximum surge current Thermal disconnect device Status indicators visually verify protection level Surge protection device with n-pe residual current spark gap as 3+1 circuit Specifications about m40b3+n Parameterm40dnpe50 Iec /vde level ii/c ii/c Nominal operating voltage 110/220v ac 500v(n-pe) Max. Continuous operating voltage 275v 61630;/250v Leakage current at 1ma
LZA-C Series.
Function of the surge protector This product is used for the control center, convenient for 1U standard Rack Mount. It is suitable in matrix and DVRs. Features 1. With integration and small volume, easy for wiring and installation; 2. Advanced surge protection; short response time, low residual voltage, and long service life. Technology Parameters Nominal Voltage 5V Insertion loss Less than 0.3dB Max. Continuous dc Voltage UC 8V Response time Less than 1ns Max. Through Flow Rate 5KA Impedance 75¦¸ Data Transmission Speed VS 10M Interface BNC Working Temperature Range: -25~+65 Celcius Degree Humidity Range: 5%~95% 20-5000 0.11kg 13*3*3(cm)
Upto 400kv As per customer requirement
SPD, surge protector, arrestor, antenna feeder SPD.
We could supply hollow insulator for Cable from 40.5KV to 420KV as per standard ANSI, IEC, BS, AS, DIN or according to the customer's requirement.
Glass insulator.
Cutout insulator(Brown colour), we could also supply insulator from 10KV to 38KV in grey blue and so on.
We could supply silicon insulators for fuse cutout from 10KV to 40.5KV.