Product Description Extreme Knob Kit, fits all Accurate Boss, Extreme and ATD reels. Includes knob in either silver or blue, pin and screws. Click option button if this is going to be installed on a SR spinning reel. A different screw is provided to mount to handle arm. Use this option for Boss arms that are flat where the pin mounts (no keyway).
We are a technology enterprise specializing in the production of various Craftwork badges, integrating design, production, research and development, and sales. The company has advanced technical equipment and a professional team, and its products have received unanimous praise from a large number of users. The minimum order quantity is 50 pieces, payment method is TT, and shipping terms are FOB.We can also customize according to your needs.
We are a technology enterprise specializing in the production of various Craftwork badges, integrating design, production, research and development, and sales. The company has advanced technical equipment and a professional team, and its products have received unanimous praise from a large number of users. The minimum order quantity is 50 pieces, payment method is TT, and shipping terms are FOB.We can also customize according to your needs.
We are a technology enterprise specializing in the production of various Craftwork badges, integrating design, production, research and development, and sales. The company has advanced technical equipment and a professional team, and its products have received unanimous praise from a large number of users. The minimum order quantity is 50 pieces, payment method is TT, and shipping terms are FOB.We can also customize according to your needs.
Model Number CW5001200US Connection Plug In Product Name AC Adapter Input voltage 100-240VAC 50/60Hz Output 5VDC 1.2A / 6W (3-24V, 0.01-1.20A) Plug US (UK EU AU KC PSE...available) Color Black/White Certificate CB CE GS UL ETL FCC C-tick SAA KC PSE ROHS Protection Short Circuit / Overload / Overvoltage Efficiency VI Warranty: 2 Year
Measurement: Luminous Intensity Data, Photometric Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency, Luminance Distribution(Option), Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela Diagrams, Efficient Luminescence Angle, EEI, UGR, etc. Features: he near field detector moves together with the big mirror in a line. The big mirror and the far field detector move synchronously.The burning position of the lumainares will be kept without moving at all, and the detector will always sense the light directly from the luminares. The rotary motor is from Japan MITSUBISHI MOTORS and the angle decode system is from Germany. They help the goniophotometer rotating smoothly with high accuracy. It is very stable when start and stop. The working principles are according to IESNA and CIE. The LSG-6000 completely meet the LM-80, LM-79, LM-75, GB, EN and CIE121-1996 standards. Special collimation device with cross laser line help you installing the position of the luminaires under test conveniently and accurately. Specifications: The mirror and detector rotates around the luminaire under test with an angle of () vertical axis ±180 (or 0-360) and the luminaire rotates around itself with an angle of (C) horizontal axis ±180 (or 0-360 ). The accuracy of angle: 0.05, Resolution of angle: 0.001 Accuracy of Goniophotometry detector: Constant temperature photo detector DIN5032-6/CIE pub1. No. 69 Class L LISUN goniophotometer software can export CIE, IES, LDT and other format files. These kinds of format files can be used via other illumination and luminaire design software such as DiaLux. Connect the goniophotometer to PC via USB cable. English version software can run on Win7, Win8 or Win10, Win11 LSG-6000 can be used together with a CCD Spectroradiometer to test spatial CCT Distribution and other Spectral color parameters. We call this system Goniospectroradiometer (LSG-6000CCD)â??. LSG-6000CCD Goniospectroradiometer = LSG-6000 Goniophotometer System + LPCE-2 Integrating sphere Spectroradiometer System. Please click to download the LSG-6000CCD Brochure The LSG-6000CCD software and hardware support the plant lighting PAR, PPF and PPFD spatial distribution test , and it can export IES/LDT files
Safety Inflation Hose Systems Color-coded Safety Inflation Hose Systems, composed of 15 feet of 1/4 or 3/8 air line, pressure regulator, liquid filled pressure gauge, ball valve and appropriate safety valve (25 or 45 P.S.I.). Length of hoses may vary upon customer request.
Manhole Pulleys Manhole top roller: Made from steel and aluminium. 48 long, for a solid and steady hold on the sides of the manhole. Longer configurations available upon request. Manhole pulley - bottom section: All-steel build, held from the top of the manhole. Bottom manhole pulley: Robust model, all-steel build. Adjustable for installation in the opening of the pipe during use.
Logiscell+ activated oakum kit is composed of dry oakum soaked into a hydrophilic polymer solution to seal manholes and sewer lines. When wet and caulked in a joint or crack, the resin will foam to form a flexible and tight joint to stop groundwater infiltration. It reacts with water and becomes a watertight rubberlike non-toxic composite. The oakum cord gives strength and density to the composite and makes the application of the resin easier, especially when gushers are present. The kit includes a 1.7-liter bottle of Logiscell+ (hydrophilic resin) and one bag containing a �± 0.6 lbs of dry oakum. 18 liter pails also available. ACTIVATED OAKUM TECHNIQUE: 1) When mixed with water the resin forms a spongy foam which could absorb up to 12 times its volume of water. A non-controlled expansion could create a low-density foam, which is less watertight and resistant. If the oakum is well-inserted and uniform within the area, a good density and expansion is obtained to fill the void and stop leaks. 2) After approximately 40 seconds, the reinforced foam resin starts to react to form a rubbery gasket which becomes hard, watertight and adheres to the surface. Note: If there is a significant flow within the joint or crack, it is preferable to soak the oakum and let it partially react before the insertion in the crack or joint. By holding it tightly within the crack or joint, the resin will not be washed away by the gushing water. This technique can also be used for underwater applications. CAUTION: Prevent any contact with eyes and skin. Always wear PPE (gloves, goggles, disposable suit and mask or respirator depending on the environment). Certain people may be affected by the vapours during the reaction of the resin. To prevent irritation of throat or eyes always ventilate the working area. If it is impossible to ventilate use a mask with appropriate cartridge. Wash hands and face thoroughly after installation.
Deflection Gauges for Pipe Testing Logiball Deflection Gauges use a nine-arm design to make sure the pipe is accurately tested. Made entirely from steel, their lengths are at least the nominal diameter of the pipe. Stainless steel build also available. Available for 5% or 7.5% deflection for 6â?³ to 21â?³ pipe. Built for the standards required by the customer (BNQ, ASTM or other).
Hand Crank Winch Used to pull various pieces of equipment in the main line sewer, such as sleeve installers, carriers, lateral launcher, deflection gauges, kit of inflatable plugs for segmental testing, etc. Easy to move by flipping the winch on its wheel and using the legs as handles. Setup allows two different speeds. The winch is provided with 500 feet of 3/16" galvanized steel cable. Easily dismantled for convenient storage
Easy to use. One tablet for 227 liters of water (60 US gallons) Dissolves in 5-8 minutes Available in yellow/green, red or blue. These bright dye tablets are used to: Detect leaks in sewage systems Trace water and industrial effluents Trace cross connection systems Measure power plant discharge Detect toilet tank leaks Detect illegal sewer connections Monitor flow studies and mapping Analyse septic systems Features Available in fluorescent yellow/green, red or blue : Florescent yellow/green : Most popular color Greater apparent contrast in murky brown water May be used for visual, ultraviolet and fluorometric inspections Photo degradation takes plase in sunlight within 2-3 days Blue : Storm & sewer drain Offers excellent contrast in clay pipes when using color cameras May be used for visual inspections Generally blue may be more acceptable to public view Photo degradation starts to take place in 2 to 3 weeks Red : Offers greater contrast to heavy concentrations of green algae May be used for visual, ultraviolet* and fluorometric inspections Has a higher light fastness than FLT Yellow/Green, taking approximately 5-7 days to fade
Flexible Push-Type Test Rig for Segmental Pipe Testing Logiball Push-Type Test Rig is used for segmental air testing of lateral lines, from the cleanout or above ground access. The standard test chamber between the two inflatable bladders is 5 feet long. A 3/4 semi-rigid hose is used as a push rod and to inflate both bladders in one operation. Air for the test chamber is supplied thru a 1/2 semi-rigid hose to be used as a second push rod and lateral test line. Logiball Flexible Push-Type Test Rig can be used in lines 4 to 6 inch in diameter. For sealing defective laterals using chemical grout, use the Flexible Push/Pull Type Packers The control system for inflation & test is offered separately.
Keep the flow under control when flushing fire hydrants. Avoid the washout of the surrounding soil. Increase rapidity and security when flushing hydrants. Keep traffic interruptions to a minimum. Easy to handle and carry. Comes standard with 5 feet of 2.5â?? discharge hose & 2.5â?? QST female adapter. Available with a longer hose & different adapter
Sewer Lateral Cleaning Launcher Logiball Sewer Lateral Cleaning Launcher is used to clean laterals from the mainline sewer without the need of a cleanout. It can effectively clean laterals (removing roots, grease and other buildups) as far as 50 feet from the connection. Logiball Lateral Launcher guides your 1/2â?? or 3/8â?³ hose and nozzle into the lateral connection from the mainline sewer. Winched in tandem with the CCTV camera, the 0-90 VDC motor is used to rotate the guiding arm and nozzle into the lateral connection. Typical multiconductor cable required. With the pump turned on, the back jets propel your nozzle and hose into the lateral for cleaning. ALSO AVAILABLE: Lateral Launcher for 6" / 150mm mainline with 0-24 vdc motor Features Stainless steel and aluminium construction Industry standard 4 pin male connector (multiconductor camera cable) 0-90 VDC motor Use tractor controls with multiconductor cable for CW/CCW rotation Replaceable guiding arm Optional control panel for motor rotation of lateral launcher 8 to 18 main assembly For sewer lateral cleaning launchers from 6 mainline contact our sales department
PR11 TEA, a Triethanolamine (TEA) Activator, is a catalyst to be used with PR10 ACLM acrylamide products as an activator for reaction. TDS SDS PR11 TEA Canadian French SDS PR11 TEA Canadian English SDS PR11 TEA US English SDS PR12 APSF is a catalyst to be used with PR10 ACLM acrylamide. It is a white crystalline solid and used as a polymerization initiator. Ammonium persulfate is a powder that is a required grout component. PR12 APSF decomposes over time as it is a strong oxidizing material TDS SDS PR12 APSF Canadian French SDS PR12 APSF Canadian English SDS PR12 APSF US English SDS PR13 SPSF (Sodium Persulfate) is a catalyst to be used with PR10 ACLM acrylamide. It is a white crystalline solid and used as a polymerization initiator. Sodium persulfate is a powder that is a required grout component and can be increased from 5 lbs. (1% by total mix weight of 500 lbs., 60 oz. by volume to a maximum of 15 lbs. (3% by total mix weight of 500 lbs., 180 oz. by volume). PR13 SPSF decomposes over time as it is a strong oxidizing material. TDS SDS PR13 SPSF Canadian French SDS PR13 SPSF Canadian English SDS PR13 SPSF US English SDS PR17 LYTX is a water-based additive to strengthen gel and reduce shrinkage. With acrylamide, replace up to 2 gallons mix water with PR17 LYTX in each tank. Seals leaks in sanitary and storm water mainlines, pipe penetrations, laterals, lift stations and manholes. TDS SDS PR17 LYTX Canadian French SDS PR17 LYTX Canadian English SDS PR17 LYTX US English SDS
Design allows to seal laterals connected to manholes. Injections have been done up to 30 feet. Logiball Man Entry Pipe Lateral Grouter is an inflatable bladder with threaded adapter used to install our standard lateral grouting plugs to seal laterals from a man entry pipe or a manhole. It includes one inflation port for the lateral bladder, one inflation port for the 4-6 bladder, two ports for the chemical grout and one void liquid filled pressure sensor line.
Lateral Test and Seal Packers Logiball 2001L packers are used to test and seal off infiltration in sewer laterals, from the mainline, without any access to cleanouts. The lateral grouting plug is inverted and deployed into the lateral from the mainline packer assembly. The mainline sleeve then expands to create a minimal grout mixing chamber. The grout is pumped and migrates freely along the restricted expansion of the lateral plug and out through existing pipe defects into the surrounding bedding to seals defects, leaving only a thin layer of grout in the lateral. The packers are available with different void pressure monitoring systems; a conventional localized liquid filled sensor (S), recommended for acrylamide and acrylate grouts, an in-wall water chamber sensor (W), recommended for stickier grouts such as urethanes and polyurethanes, or both systems (S+W) for a more versatile use. The 2001L Lateral Packer comes standard with two grout ports and a third port dedicated for the test medium (air or water). 2001L Lateral packers work best with a five-hose system. Lateral Grouting Plugs can be interchanged in a matter of minutes to grout distances up to 30 feet if necessary. Lateral Grouting Plugs are available for 4, 5 or 6 diameter laterals. Flexible housing extensions are needed for lateral grouting plugs 24 or longer. ICGA promotes the proper use of chemical grouting as a safe, economical and effective means to reduce ground water infiltration into sewer collection systems. The 2001L model is available for 6â?³, 8â?³, 9â?³, 10â?³, 12â?³, 15â?³, 18â?³, 21â?³, 24â?³ and 30â?³ mainlines. For larger diameter contact our sales department. For larger diameters, see our Man Entry Lateral Packers for 36â??â?? & up or contact our sales department. Features * As measured on the rubber. Specifications subject to change without notice. Logiball Lateral Packer Approximate Void Volumes. View list of parts for the lateral packers 2001L. (pdf file) A Control Panel is available to operate the lateral packer from the truck.
Logiball Elliptical Mainline test and seal injection packers are custom-made for the exact pipe dimensions and the available access to the storm sewer lines. The two end rubber bladders are covered with a soft rubber sleeve that provides superior seating against rough surfaces. Our elliptical grout packers are equipped with a localized pressure sensor and two injection grouting ports protected by a large, non-clogging adjustable rubber check-valves. Contact us if you need a special configuration. Rentals available, contact our sales department for further information.
2001J Mainline Packers meet the highest standards for testing and sealing joints of mainline sewer pipes with acrylamide, acrylate or urethane gels. Logiball 2001J Mainline Packers meet the highest standards for testing and sealing joints of mainline sewer pipes with acrylamide, acrylate or urethane gels. A thick, reinforced SBR rubber sleeve is bonded to the stainless-steel core and a layer of softer rubber is applied over the seating portion to provide superior seating against rough surfaces. The smooth outer finish reduces the adherence of the grout on the packer. Logiball 2001J Mainline Packers come with two grout ports and a third port dedicated for the test medium (air or water). MAIN FEATURES: Void Pressure Monitoring Systems: Two different void pressure monitoring systems are available to accurately transmit the void test and grouting pressures to a gauge read by the camera or through a pressure transducer. The conventional localized sensor is recommended for acrylamide and acrylate grouts. The in-wall water chamber sensor is recommended for stickier grouts such as urethane gels and polyurethanes. The 2001J Packer can be ordered with both systems or one of the two as needed by customer. Dedicated Test Port: By using a dedicated hose from the truck to the packer for the test medium (air/water), â??Hâ?? blocks are eliminated and the mixing ratio of the two-part grout is kept constant (no flushing of the catalyst when testing). Features Three-Function Adjustable Rubber Check-Valve: They provide added safety against syphoning the tanks and unwanted backflow contamination into the hoses, and provide a good mixing of the two-part chemicals through the fan like stream of the opposed and adjacent ports. The Autotesting Concept: When inflating the 2001J packers, the ends first seal against the pipe wall, while its central portion progressively expands, trapping air and water, and compressing it into the mixing chamber. The pressure in the chamber is transmitted through the improved liquid filled sensor and/or the in-wall water chamber sensor to a gauge or transducer installed on the packer. The operator can tell if a joint is obviously good or not by simply inflating the packer over it. By avoiding time consuming conventional tests, productivity could be increased by as much as 30%. Logiball 2001J Packers approximate void volumes. ICGA promotes the proper use of chemical grouting as a safe, economical and effective mean to reduce ground water.