8 channel 1080P Full HD HDD mobile DVR; H.264 high profile.Industrial good vibration absorber and heat-dissipated level design. Set all menu via WIFI with Ipad/Iphone/Android and PC. Mirror function set on the MDVR menu directly. Connect acceleration sensor, temperature sensor, oil/fuel sensor.Control panel, LED panel ,Counter camera, Oxygen sensor and other peripherals through RS232/RS485 interface. With aviation connector, stable and reliable; Special interface for HDD vehicle Mobile DVR, convenient for transportation and installation. Support speed, turn, brake, reversing, door opening and closing. Support 8-CH 1080P/720P/960H/D1/HD1/CIF; 4CH audio& video. Support G-sensor,Geo-fence,GPS, 3G/4G, WIFI(more fast and stable) for optional. Support Vehicle PTZ local and remote control, Support USB interface, support firebox as mirror backup. Support max 2.5 inch 2TB HDD/SSD and 1 SD card dual storage. DC8V~36V wide voltage supply,aluminum housing,low power consumption. Power off can work 8 seconds and 1~2 hour with UPS battery. G sensor dvr recorder Product size:199x76x190mm.
Input: AC/DC 20-100A; Output: DC 0-5V; Accuracy: 1.0%; Power supply: DC 12V, 15V, 24V.
Features P/N: SP9325A Philips-HP-Agilent adult clip SpO2 sensor Latex free 3m TPU cable One year warranty CE/ISO 13485 FSC FDA Packages: non-sterilization, individual package with instruction Compatibility Philips-HP-Agilent:MP20,MP30,MP40/50/60/70/90,VM4,VM6,VM8,M3046A Specifications Safety: IEC 60601-1-1 approved, conformity with MDD 93/42/EEC EN9919:2005 Patient sizes:Adult Ambient temperature: 0 to 40 (32 to 104) Relative humidity: 15% to 95% Measurement technology: Tri-wavelength LEDs & photo detector LED wavelength: 660nm/880nm/905nm SpO2 accuracy: ±3 (70-100%); Unspecified (0-69%) Pulse rate range: 20-250bpm Pulse rate accuracy: ±3 (20-250bpm)
5.8GHz C-band microwave, tri-level dimming function; Input voltage: 12/24V DC; Input current: â?¥25mA; 1~10V DC dimming output signal; Super compact, flexible to be integrated into any suitable fixtures; Dual-processor technology, real daylight minitoring function for built-in application; 8 pin DIP switch setting, multiple options to meet different customer demands; Detection range up to 12m in diameter; Operation temperature: -20~+70 degree; RoHS compliant The price is to be negotiated
Usage: Pressure Sensor, Direct spo2 sensor connected to the monitor, no need for extension cable. Compatible Mode: AS/3, CS/3, CH/S, CH/2S, CH-RS, CG/2S, Cardicap I, Cardicap II, Cardicap 5, Capnomac Ultima, Light Monitor: M-Estpr, Oscar II, OSP-200, Satlite Trans, SatliteTrans Plus, System 5ULTS00, ULTSIO, ULTSVI, ULTSVO
Usage: Pressure Sensor, Direct spo2 sensor connected to the monitor, no need for extension cable. Compatible Mode: Nellcor N100, N180, N200, N-20, NPB-50, NPB-75, NPB-290, NPB-295, N-390, N-395, N-3000, N-6000
Main FeaturesAC/DC Current Sensor Model No.: MEWOI-DRK1D Name: MEWOI-DRK1D-50-500A AC/DC Ï?20mm Open-loop Hall current Sensor Jaw Size21mm Rated input Current IPN50 100 200 300 400 500 A Primary Current Measure range(IP)0~±100 0~±200 0~±400 0~±600 0~±800 0~±800 A Rated output voltage of secondary side2.5±1.25 ±1% V Power Supply Voltage VCCDC +5V ±5% V Current consumptionVCC=+5V 10 mA Galvanic isolation (Vd) 2.5KV /50Hz/1min
LOX-02-S LuminOx Sealed Optical Oxygen Sensor General Description The LuminOx Sealed Optical Oxygen Sensor Range Offers Users With Application Requirements To Only Measure Sample Gas At The Front Face Of The Sensor. The LuminOx Sealed Optical Oxygen Sensor is developed and manufactured by SST, it is part of the LuminOx family, which is a range of factory calibrated oxygen sensors which measure ambient oxygen levels using the principle of luminescence quenching. The LuminOx Sealed Optical Oxygen Sensor (LOX-02-S) is an extension to the standard range of LuminOx oxygen sensors. It is a similar diffusion type sensor like the original LOX-02 sensor. However, the LOX-02-S has a sealed base that is gas-tight, meaning only the face of the sensor with the protective membrane needs to be in the sample gas environment, externally leaving easy access to the pins of the sensor. LOX-02-S LuminOx Sealed Optical Oxygen Sensor Features * Luminescence-based optical technology, NOT electrochemical * Contains no hazardous materials; RoHS & REACH compliant * Connects directly to a microcontroller without any additional circuitry * Factory calibrated * High accuracy * Maintenance free LOX-02-S LuminOx Sealed Optical Oxygen Sensor Benefits * Compact, diffusion-type housing with sealed base * Low power, long life due to non-depleting sensing principle * Low cost LOX-02-S LuminOx Sealed Optical Oxygen Sensor Technical Specifications * Oxygen range: 0 - 25% O2 * Oxygen pressure range: 0 - 300mbar ppO2 * Response time: T90 < 30s (typical) * Supply voltage: 4.5 - 5.5V DC * Supply current:
5 PSI-D-4V-MIL Amplified Middle Pressure Sensor General Description The Amplified line of middle pressure sensors is based upon a proprietary package technology to reduce errors. This model provides a ratiometric 4-volt output with superior output characteristics. The sensor housing has been designed specifically to reduce package induced parasitic stress and strain. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pressure. These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. Each sensor is internally compensated using an ASIC compensation technique. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts. 5 PSI-D-4V-MIL Amplified Middle Pressure Sensor Features * ±5 psi Pressure Ranges * Ratiometric 4V Output * Temperature Compensated (-40 degree C to 125 degree C) * Calibrated Zero and Span 5 PSI-D-4V-MIL Amplified Middle Pressure Sensor Applications * Medical Instrumentation * Environmental Controls * HVAC
HG-B40A/HG-B40C Combi ASIC Ultrasonic Sensor & Module Features * Low-power, high-sensitivity module. * Choose from a wide variety of input/output Mode. * Auto sensitivity control function as a distance proportional to the distance error captain. * The same standards as existing foreign products and mutually replaceable. HG-B40A/HG-B40C Combi ASIC Ultrasonic Sensor & Module Specification * Receiver Output Signal: Analog: ±2 V max at 2.5 V Base Line Real Time Pulse: 4~5 V TTL, All the objects detected Distance Pulse: 4~5 V TTL Only the nearest Object * Choose from a wide variety of input/output Mode. * Detecting Range: 0~3 m (Conventional, HG-B40C) (at 5Vdc) 0~6 m (Conventional, HG-B40C) (12 Vdc) b0~3 m (Anistropic, HG-B40A) (12 Vdc)
DGS-CO 968-034 Digital CO Sensor Module DESCRIPTION Easily add Carbon Monoxide sensing to your IoT application with our digital CO sensor module that provides a calibrated and temperature compensated output. 0 to 1000 ppm Carbon Monoxide sensor with digital output DGS-CO 968-034 Digital CO Sensor Module BENEFITS * Low Power - 1 mW @ 1 minute sampling * Fast Response - 15 seconds typical * Calibrated & Temp. Compensated Output * Simple Digital UART Interface * Integrated T & RH Sensors * Robust 10-year Estimated Lifetime * ROHS Compliant * Small form Factor * UART to USB adapter provided * Lightweight (< 2 oz.) DGS-CO 968-034 Digital CO Sensor Module APPLICATIONS * Life Safety Levels * Air Quality Levels DGS-CO 968-034 Digital CO Sensor Module MEASUREMENT PERFORMANCE CHARACTERISTICS Based on Standard Conditions 25'C, 50% RH and 1 atm * Measurement Range: 0 to 1000 ppm * Resolution: 0.1 ppm * Zero Accuracy:± 1 ppm * Measurement Accuracy: 15% of reading * Measurement Repeatability:
VPA.8000.1013 Dew Point Sensor Product Description VPInstruments' dew point sensors are designed for ease of use, incorporating all the features needed to make installation and operation as simple as possible. The calibrated transmitters can be instantly incorporated into VPVision or they can be connected to your air or gas management and control system. Maintaining the dew point of your air or gas system will prolong the life of your equipment. Permanent monitoring enables you to detect and prevent problems in time. We offer various models which meet both moderate dry air (refrigerant dryer) and extreme dry air (dessicant dryer) applications. VPA.8000.1013 Dew Point Sensor Features and benefits For moderate dry air 3-wire loop powered connection Dew point or ppm moisture content IP66 (NEMA 4X) Excellent sensor protection Fast response time VPA.8000.1013 Dew Point Sensor Application Moderate dry air (refrigerant dryer) PA.8000.1013 Dew Point Sensor Specifications Dew point range: -40 ~ +60'C (-40 ~ 140'F) dew point Temperature: -30 ~ +70'C (-22 ~ 158°F) Humidity: 0 ~ 95% RH (non-condensing) Pressure: 20 barg maximum Output: 4 - 20 mA 3-wire Power supply: 8 - 30 VDC
3SP_NO2_5F C NO2 Sensor DESCRIPTION SPEC's printed sensors offer the performance of the best quality electrochemical sensors at a fraction of the price. SPEC's printed sensors are also ultra-thin, offering easy integration into wireless, portable, and networked solutions. These sensors are ideal for health, environmental, industrial and residential monitoring, because of their high performance, low cost and small size. 3SP_NO2_5F C NO2 Sensor BENEFITS * NEW Onboard Filter Removes Ozone!!! * NEW More Stable with T & RH!!! * Small Size with Low Profile (20x20x3 mm) * Long Life (10 years expected life) * Fast Response (< 15 seconds) * Low Power Consumption * ROHS Compliant 3SP_NO2_5F C NO2 Sensor APPLICATIONS * Air Quality Monitoring * Industrial Safety * Air Purification Control 3SP_NO2_5F C NO2 Sensor SPECIFICATIONS * Measurement Range: 0 to 5 ppm * Resolution: < 20 ppb (instrumentation dependent) * Repeatability: < +/- 3 % of reading * Response Time T90: < 300 ( 200 seconds typical) * Sensitivity -25 mV bias: -30 +/- 15 nA/ppm * Expected Operating Life: > 5 years (10 years 23+/-3'C; 40+/-10% RH) * Operating Temperature Range: -40 to 50'C (-20 to 40'C recommended) * Operating Humidity Range - non-condensing: 0 to >95% RH (15 to 95% continuous) * Power Consumption: 10 to 50 uW (circuit & ambient NO2 dependent)
Zirconia o2 sensors Probe series - long housing Features * zirconium dioxide (zro2) sensing elements * long life, non-depleting technology * integral heating element * high accuracy * requires an external interface board to operate Benefits * no reference gas required * no need for temperature stabilisation * two lengths available; 220mm and 400mm Technical specifications Heater voltage Operating: 4v dc ± 0.1v dc (1.7a) Standby: 1.65v dc (0.7a) Pump impedance at 700'c: < 6k Permissible gas temperature Standard temperature: -100'c to +250'c High temperature: -100'c to +400'c Gas flow rate: 0 - 10 m/s Repetitive permissible acceleration: 5g Incidental permissible acceleration: 30g Output values Oxygen pressure range: 2mbar - 3bar max Accuracy: 5 mbar max Internal operational temperature: 700'c Response time (10 - 90% step): < 15s Warm up time (prior to sensor operation): 100s Warm up time (from stand by): 20s Output stabilisation time: ~ 180s
Zirconia o2 sensors Flange mounted series The flange mount zirconium dioxide oxygen sensor is designed for easy sealing into a manifold or sampling chamber. Favoured by ssts aerospace customers and in applications that require high temperature and pressure operation. O2s-fr-t4-4p flange zirconia o2 sensors features Zirconium dioxide (zro2) sensing elements Long life, non-depleting technology Integral heating element High accuracy Requires an external interface board to operate O2s-fr-t4-4p flange zirconia o2 sensors benefits No reference gas required No need for temperature stabilisation Flange mounting O2s-fr-t4-4p flange zirconia o2 sensors technical specifications Heater voltage Operating: 4.35vdc ± 0.1vdc (1.85a) Standby: 2vdc (0.85a) Pump impedance at 700'c: < 6k Permissible gas temperature: -100'c to +400'c Gas flow rate: 0 - 10 m/s Repetitive permissible acceleration : 5g Incidental permissible acceleration: 30g O2s-fr-t4-4p flange zirconia o2 sensors output values Oxygen pressure range: 2mbar - 3bar max Accuracy: 5mbar max Internal operational temp: 700'c Response time (10 - 90% step): < 4s Warm up time (prior to sensor operation): 60s Warm up time (from standby): 20s Output stabilisation time: ~ 180s
Air flow 1 sensor (nc) rma-af1-sen overview Air flow 1 sensor (nc) provides real-time recognition of air flow stoppage. This air movement sensor is normally closed and includes a mounting clip and clamp. Typical use is for measuring air flow in an hvac duct, under a raised floor, or near a fan on a rack cabinet or important server. This is an instant 'plug & play' sensor via one of the switch sensor channels on the back of any compatible room alert id box. Cable distance can be extended from the standard 25' to approximately 900' by using standard speaker wire, twisted pair or any reliable low voltage 2-wire cable. This sensor is equivalent to the discontinued stego air flow sensor #01300.0. Air flow 1 sensor (nc) rma-af1-sen features & specification Environment condition monitored: air flow Real-time recognition: air flow stop/start (normally closed) Power supply: monitoring unit Sensor cable type: 2 wire sensor cable Sensor cable length: 25' Maximum sensor: cable length approximately 900' Compatible products: room alert 32w, 32e, 26w, 26wo, 24e, 12e, 11e, 7e, 4e, 3e & 3 wi-fi
Low power carbon dioxide sensor nrid co2 gas sensor cozir-a description Cozir is an ultra low power (3.5mw), high performance co2 sensor, ideally suited for battery operation and portable instruments. Based on patented ir led and detector technology and innovative optical designs, cozir is the lowest power ndir sensor available. Optional temperature and humidity sensing are available. Cozir is a third generation product from gas sensing solutions ltd ? leaders in ir led co2 sensing. With measurement ranges of 0-2000ppm, 0-5000ppm and 0-1% the cozir ambient sensor is suitable for applications such as building control and horticulture. * ultra-low power 3.5mw * measurement ranges from 0 to 1% * low noise measurement
SO-E2-960 Limiting Current Type Sensor Oxygen Sensors When voltage is applied to a zirconia electrolyte cell, oxygen is pumped through the zirconia disc from the cathode side to the anode side because the carriers of the current flowing through the zirconia electrolyte are oxygen ions. By attaching a cap with a pinhole on the cathode side of the cell and by increasing the voltage over the cell the current shows saturation due to the rate limiting step in the transfer of oxygen to the cathode. This saturation current is called limiting current and is nearly proportional to the ambient oxygen concentration. Below the advantages of the oxygen sensor: measuring range 1.00 to 96.0 vol.% oxygen High accuracy For many types a more or less linear characteristic Small temperature dependence of the sensor signal Low interference with other gases Long service life In many cases "Single point calibration" necessary only once Applications: Medical Laboratory Food industry Household/Gastronomy Measuring technique Security technology/Monitoring (Electrical-) industry Characteristic Data: Measuring gas: Oxygen concentration Measuring medium: Gaseous atmosphere Measuring principle: Limiting current type sensor Measuring ranges: 1.00 - 96.0 vol.% O2 Response time (t90): 2 to 25 sec. (Depends on: sensor type, gas flow, measuring chamber) Sensor voltage / heating voltage / power consumption / heater cold resistance Sensor voltage: 0.7 to 1.6 Volt Heating voltage: 3.6 - 4.4 Volts Power consumption: 1.3 to 1.8 Watts (depends on application and packaging) Cold resistance: R( 25'C ) = 3.25 ohm ± 0.20 ohm Warm up time: Min. 30 s
1. Ftatures - Chip size: 0.4mm, SMD 3528 PKG - Aluminium Gallium Nitride Based Material - Schottky-type Photodiode - Photovoltaic Mode Operation - Good Visible Blindness - High Responsivity and Low Dark Current 2. Application UV Index Monitoring 3. Absolute Maximum Ratings Storage Temperature: -40~90'C Operating Temperature: -30~85'C Reverse Voltage: 3V Forward Current: 1mA Optical Source Power Range: 0.1u~100m W/cm2 Soldering Temperature: 260'C 5. Characteristics (at 25'C) Dark Current: 1nA Temperature Coefficient: 0.1%/'C Responsivity: 0.11A/W Spectral Detection Range: 240~320nm Active area: 0.076mm2 -
1. Features Aluminium Gallium Nitride Based Material Schottky-type Photodiode Photovoltaic Mode Operation Good Visible Blindness High Responsivity & Low Dark Current 2. Applications UV Index Monitoring 3. Absolute Maximum Ratings Storage Temperature: -40~90'C Operating Temperature: -30~85'C Reverse Voltage: 3V Forward Current: 1mA Optical Source Power Range: 0.1µ~100m W/cm2 Soldering Temperature: 260'C 4. Characteristics (at 25'C) Dark Current: 1nA Temperature Coefficient: 0.1%/'C Responsivity: 0.11A/W Spectral Detection Range: 240~320nm Active area: 0.076mm2