1. For internal wiring of tv, radio, receivers, vtr, tape recorders and other electronic equipment. 2. Homes are now part office and part theatre, delivering internet access and digital tv with equal ease while monitoring themselves for comfort, energy consumption and security.
Foil & braid type
26 awg diameter-0.58 Material-hd-pe Over all diameter-7.00 4 pair Material-stranded tinned copper 305 m box
*this article is used in cable industry *with higher swelling speed and higher swelling height. *swelling speed>10/min;swelling height>15/min; *fast absorption 800kg/bag/pallet; 25kg/bag.
Cable unarmoured.
LMR cables.
DC cable with RCA connector dc plug for multimedia 1.RCA plug, gold plated 2.PVC plastic toslink cable 3.ROHS certificate. PVC plastic, optical fiber cable, toslink cable, DC cable with RCA connector dc plug for multimedia. 1000 or 2000 pieces per polybag
Metal RCA Plug to RCA Plug Cables with Gold Plating, audio and vedio cable digital coppper connector cable 5 pin RCA cable 5 pin RCA cables5 pin RCA cables Metal RCA Plug to RCA Plug Cables with Gold Plating, audio and vedio cable ,digital coppper connector cable Metal RCA Plug to RCA Plug Cables with Gold Plating, audio and vedio cable , digital coppper connector cable. PE bag and carton
Rubber flexible cable is used for household electrical appliances electrical tools and various mobile electrical equipments of ac rated voltage 450/750v or lower. The rubber flexible cable carries out the standard: Rated voltage 1kv ( um=1.2kv) Gb5023-1997 rubber flexible cable voltages up to and including 450/750v. Jb8735-1998 rubber flexible cable and flexible wire voltages up to and including 450/750v. The length of the cable in coil should be 100m, and that on drum should be more than 100m; the length of pieces of shorter (no shorter than 10m each) should be no more than 10% of the total length package; it depends on final both agreements with length error allowance no more than 0.5%.
1.Lenth:1.5m od:3.2 color:black 2.Raw material: 10*0.10ccs 3.Have rosh ul 3c standad 4.Use for sned audio video signal. Nature pack stand export carton.
Insulated power cable, plastic insulated power cable, aerial insulated cable, control cable, aluminum conductors steel- reinforced (ACSR), aluminum stranded conductors, polyvinyl chloride (PVC) insulated wires, various flame- retardant and fire-resistant wires and cables, special cable, etc. Weight/100m(kg).
(1).Application: ABC Cable Primarily used for 120 volt overhead service applications such as street lighting,outdoor lighting,and temporary service for construction.To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75oC for polyethylene insulated conductors or 90oC for crosslinked polyethylene(XLP)insulated conductors. (2).Construction: Code Word Phase conductor Bare Neutral Messenger Nominal Lay Length Weight Per 1000ft. (lbs.) Allowable Ampacities+ Size (AWG) Stranding Insul. Thick. (Mils) Size (AWG) Stranding Rated Strength (lbs.) inches XLP POLY XLP POLY AAC Neutral-messenger Pekingese 6 1 45 6 7 563 10.36 61 61 85 70 Collie 6 7 45 6 7 563 10.36 64 64 85 70 Dachshund 4 1 45 4 7 881 10.36 92 92 115 90 Spaniel 4 7 45 4 7 881 10.36 96 96 115 90 Doberman 2 7 45 2 7 1350 14.88 147 147 150 120 Malemute 1/0 9 60 1/0 7 1990 14.88 234 234 205 160 Wooden Drum.
CE cable :H07V-U/H07V-R/H07V-K Despription: Related temperature :70C Related voltage:300/300V Reference standard: DIN VDE 0281-3-2001 HD21.3S3:1995+A1:1999 Tinned or bare,stranded or solid copper conductor PVC/T11 insulation Application: For power supply and lighting. In rolls.
UL2464 Wire and Cable Applications: As measuring, monitoring and control cable, it is suitable for the places of machine tool manufacturing, complete equipment installation engineering, power station, refrigeratory equipment, OA equipment, data processing system and heating and air-condition system. Properties: Heat resistance, good insulation property, excellent chemical performance, extruding sheath Standards: UL 758 Structure: Conductor: fine strands of tinned copper wire, exellent corrosion resistance. Insulation: special PVC Colour: acc. to UL 758 Sheath: 80 heat-resistant flame-resistant PVC, pass VW-1 flame testing Colour: black (RAL9005) green (RAL6018) Orange(RAL2003) purple(RAL4001) Or refer to customers requirement. Technical data: Rated voltage: 300V Test voltage: 2000V Temperature range: Fixed installation: -40--+80 Flexing installation: -10--+80 The minimum bending radius: Fixed installation: 4×external diameter Flexing installation: 15×external diameter.
3.5mm ST plug to 3.5mm ST jack RCA female to 2RCA male 3.5mm ST jack to 2RCA male.
Supports Measuring Values, Output Tests, and Adaptations on control modules using the new UDS/ODX/ASAM protocol. Adds new UDS addresses and updated ODX data for 2010 models. Includes support for TP1.6 protocol which is required for the 6J Ibiza and speeds up access on many modules in other models. The Select Control Module screen now shows "Installed Modules" rather than "Common Modules" if the car being worked on is new enough to have a proper CAN Gateway. Modified SRI Screen to show more info and force user to select a job before proceeding. Adds drop-box function selection in Basic Settings and Adaptation. Reads Mileage stored in many EDC16 ECUs. New CODES file, now with over 13, 000 fault code and measuring value texts. New USB drivers for enhanced PC compatibility and stability. New firmware for HEX interfaces required for compatibility with 6J Ibiza Updated Label files; better documentation for new and existing models. Compared with the 812, the 908 has its biggest advantage. It lies in that the 908 can match Airbags under the protocol of UDS while the 812 can only read code, erase code and do coding, and it cannot match airbags. Pls check the comparence in the following pictures. The icons of 908 are activated while the ones of 812 are not. The new models that the VW launches now or in the future, such as New Bora and Lavida, will all use UDS protocol. Besides, the VAS5054 in the market nearly doesn't support UDS protocol.
ABC Cable 1) Standard: IEC60502/BS 2627 2) Voltage: 0.6/1kV 3) Certificate: ISO, CCC 4) MOQ: 3KM ABC Cable Aerial bundled cable Standard and application scope: This product is produced in accordance with the standard of IEC60502/BS 2627. The products,Cu core or Al core XLPE or HDPE aerial insulated electric power cable,may be used for the fields where the A.C.rated voltage U(Um) is 0.6/1kV. Using feature: 1) The max. long-term operating temperature of cable conductor(cable having supporting structure): a) XLPE insulation :90¡ãC b) HDPE insulated 75¡ãC 2) When short circuit (the Max. lasting time is not over 5 seconds), the Max.temperature of the cabl: a)XLPE insulated: 250¡ãC b)HDPE insulated 150¡ãC 3) When laying, the temperature should not be lower than -20oC; 4) The permitted bend radius should not be less than the diameter of cylinder that had been used for the bend testing. 5) Cables installed in air; 6) Ambient temperature:40oC 7) Intensity of solar radiation:1000w/m2.
H07RN-F Rubber Insulated & Jacketed Voltage:450/750V Standard:HD22.1/HD22.4 Size:1x1.5-630,2x1.5-95,3x1.5-300,4x1.5-300sqmm Application: The products are used for household electrical appliance, electrical tools and various mobile, electrical equipments of A.C rated voltage 450/750V or lower. Si-rubber is used as connection of appliance in moto, metallurgy, eletrical power, oil-fields, chemistry industrial, also in the process of heating for stimulating the liquid. It have weather-proof character and certain grease-proof character and are suitable for outdoor usage and the occassio with greasy dirt. Also can be used for various mobile electrical devices, bearing strong mechanical force. Standard: It is manufactuerd according to HD22.1 & HD22.4. Size: 1. Single Core: 1.5 to 630sqmm 2. Two Cores: 1.0 to 25sqmm 3. Three Cores: 1.5 to 300sqmm 4. Four Cores: 1.5 to 300sqmm 5. Five Cores: 1.5 o 25sqmm.
PVC Insulated & Sheathed Cable Cu(or Al)/PVC/PVC Standard:IEC 60502-1/BS6346 Voltage:0.6/1kV Certificate:TUV SUD PSB, CCC Standard : It is manufacture under IEC 60502-1/BS6346, also can be made to order. Application: It is used to transmit and distribute power on the power line of A.C. rated voltage 0.6/1kV. Using features: 1. Rated voltage: Uo/U: 0.6/1kV 2. No. of core: Ranging from single core to 5 cores, inlcuding earth core. 3. The highest allowed operating temperature of conductor for long-term working is 70oC. In short-circuit (Max. long-term is no more than 5 seconds), the highest temperature for conductor is no more than 160oC. 4. D.C. resistance of the conductor complies with the stipulations of IEC 60502-1/BS6346. 5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated. 7. Working Frequency Voltage Test: 2.5Uo+2kV/5min without puncture.
Structure: Solid bare copper conductor, pe insulation, center cross skeleton, aluminum foil screen, pvc/pe /lsoh sheathed. Standard: Europe celenec en 50173/50167 Usa eia/tia568b International iso/iec 11801/61156 China yd/t 1019-2001. According to client request.