Product Details: Model Name/Number : FS-114 Brand : Wondfo Temperature Control : Provide better reaction condition Convenient : easy to carry Portable : Small in size 7800mAh built-in battery Finecare FIA Meter Plus SEThe analyzer is intended for use by healthcare professionals to improve the way to diagnosing and monitoring various conditions, including COVID-19, diabetes, renal injury, cardiovascular disease, pregnancy, inflammation, tumor, etc
Product Details: Number of Reactions(Preps)/Kit : 25 Brand : CTK BioTech Result Time (Rapid Kits) ; 15 min Sample Type : Blood Test Type Rapid Test CAT No : R0162C Detects the specific antigens from either S. typhi or S. paratyphi Earlier detection results in faster treatment for disease eradication Works with a variety of specimen types including: fecal, blood culture Simple procedure minimizes operator error due to sample preparation Test result within 15 minutes allows medical professionals to take immediate action High level of reproducibility Test kits can be used and stored at room temperature Individually sealed foil pouches containing: One cassette device One desiccant Stool collection devices, each containing 1 mL Fecal Sample Extraction Buffer (REF SB-R0162) Sample diluent (REF SB-R0162-2, 5 mL/bottle) Plastic droppers Patient ID stickers One package insert (instruction for use).
Product Details: Brand : Boditech Med Incorporated Size : 25 T Samples : Human serum/plasma/control Specimen volume : 50 Microliter stored at 4 - 30 DegreeC Cat No : CFPC-89 INTENDED USE : ichroma AMH is a fluorescence Immunoassay (FIA) for the quantitative determination of AMH (Anti-m�¼llerian hormone) in human serum/plasma. It is useful as an aid in management and monitoring of premature ovarian insufficiency, menopause and ovarian reserve.For in vitro diagnostic use only. COMPONENTS : ichroma AMH consists of cartridges, detectors and diluent The cartridge contains the membrane called a test strip which has streptavidin at the test line and chicken IgY at the control line. All cartridges are individually sealed in an aluminum foil pouch containing a desiccant in a box The detector has 2 granules containing anti human AMH-fluorescence conjugate, anti-chicken IgY-fluorescence conjugate, anti-human AMH-biotin conjugate, bovine serum albumin (BSA) and sucrose as a stabilizer, MAB33 as a blocker in Tris-HCl buffer. All detectors are packed in a box The diluent contains bovine serum albumin and NaCl as a stabilizer, tween 20 and CA-630 as a surfactant and sodium azide as a preservative in phosphate buffered saline (PBS), and it is pre-dispensed in a vial. The diluent is packed in a box. PRINCIPLE : The test uses a sandwich immunodetection method; the detector antibodies in buffer bind to antigens in the sample, forming antigen-antibody complexes, and migrate onto nitrocellulose matrix to be captured by the other immobilized-antibody on test strip.More antigens in sample will form more antigen-antibody complexes which lead to stronger fluorescence signal by detector antibodies, which is processed by instrument for ichroma tests to show human AMH concentration in the sample. INTERPRETATION OF TEST RESULT : The instrument for ichroma tests calculates the test result automatically and displays AMH concentration of the test sample in terms of ng/mL The working range: 0.02- 15 ng/mL
Product Details: Number of Reactions(Preps)/Kit : 25 T Brand : Boditech Med Incorporated Sample Volume : 30 Microliter Sample : human serum / plasma / control Reaction Time ; 10 mins Cat No : CFPC-32 Ferritin Monitoring deficiency/excess of iron & inflammation Ferritin is a universal intracellular protein that stores iron and releases it in a controlled fashion. Too little ferritin can lead to anemia, while too much to liver disease, rheumatoid arthritis, other inflammatory conditions, or hyperthyroidism. The ferritin test measures the level of ferritin in the blood. INTENDED USE : ichromaâ?¢ Ferritin is a fluorescence Immunoassay (FIA) for the quantitative determination of Ferritin in human serum/plasma. It is useful as an aid for quantifying human ferritin. For in vitro diagnostic use only. PRINCIPLE : The test uses a sandwich immunodetection method; the detector antibodies in buffer bind to antigen in the sample, forming antigen-antibody complexes, and migrates onto nitrocellulose matrix to be captured by the other immobilized-antibodies on test strip. More antigens in the sample will form more antigen-antibody complexes which lead to stronger fluorescence signal by detector antibodies, which is processed by Instrument for ichrom tests to show ferritin concentration in sample. MATERIALS SUPPLIED : REF CFPC-32 Components of ichroma Ferritin Cartridge Box: - Cartridge 25 - Detector 25 - Detector Diluent 1 - ID Chip 1 - Instruction for Use 1
Product Details: Number of Reactions(Preps)/Kit : 10 Brand : CTK BioTech Result Time (Rapid Kits) : 20Min Sample Material ; Serum / Plasma / Whole Blood Cat. No : R0063c The OnSite Dengue Ag rapid Test CE is a lateral flow chromatographic immunoassay for the qualitative detection of dengue NS1 antigen (DEN1, 2, 3, 4) in human serum, plasma or whole blood. The test is designed to be used by professionals as a screening test and provides a preliminary test result to aid in the diagnosis of infection with dengue virus. Any use or interpretation of this preliminary test result must also rely on other clinical findings and the professional judgment of health care providers. Alternative test method(s) should be considered to confirm the test result obtained by this device. Recommended for use: Any person presenting with clinical signs or symptoms within 9 days consistent with acute dengue infection or dengue fever including: high fever, severe headaches, severe pain behind the eyes, severe joint and muscle pain, fatigue, nausea, vomiting, and/or skin rash. Dengue NS1 antigen is detectable in human blood from the first day after the onset of fever up to 9 days, which allows early detection and prompt treatment of infection with dengue virus. As mild dengue fever symptoms can overlap with acute clinical manifestations of other arbovirus infections, such as Zika virus and chikungunya virus infections, correct diagnosis of dengue infection during early disease onset is critical for guiding clinical patient management. Product Specification: Individually sealed foil pouches containing: One cassette device One desiccant Plastic droppers Sample diluent (REF SB-R0063, 5 mL/bottle) One package insert (instruction for use)
Product Details: Number of Reactions(Preps)/Kit : 25 T Brand : Boditech Med Incorporated Sample : whole blood (AFIAS), plasma, serum Reaction Time : 15mins Detection Range : ichroma(TM) (1 - 100 mIU/ml) Cat No : CEPC-35 Follicle-stimulating Hormone (FSH) Diagnosis of early menopause & ovarian degeneration and infertility This test can help figure out the cause of infertility, problems with ovarian functions, menstrual abnormalities and congenital or acquired gonadotropin development disorder or infertility.
Product Details: Brand: Boditech Med Incorporated Size : 25 T Samples : human whole blood/serum/plasma Specimen volume ; 150 microliter stored at 4-30 DegreeC Cat No : CFPC-23-1 PCT Assessing initial risk of bacterial infection and fatal sepsis Diagnosis of sepsis is routinely performed in intensive care units (ICU) of all hospitals. Early detection of sepsis is very important in determining appropriate treatment as it is known to improve patient survival through a various therapeutic strategy for sepsis. The ichroma & AFIAS PCT test helps detect bacterial sepsis and assess the risk of developing septic shock. INTENDED USE : ichroma PCT is a fluorescence Immunoassay (FIA) for the quantitative determination of Procalcitonin (PCT) in human whole blood/serum/plasma. It is useful as an aid in management and monitoring of bacterial infection and sepsis. For in vitro diagnostic use only. PRINCIPLE : The test uses a sandwich immunodetection method; the detector antibody in buffer binds to antigen in sample, forming antigen-antibody complexes, and migrates onto nitrocellulose matrix to be captured by the other immobilized-antibody on test strip. The more antigen in sample forms the more antigen-antibody complex and leads to stronger intensity of fluorescence signal on detector antibody, which is processed by instrument for ichromaâ?¢ tests to show PCT concentration in sample. STORAGE AND STABILITY: The cartridge is stable for 20 months (while sealed in an aluminum foil pouch) if stored at 4-30 C. The detection buffer dispensed in a tube is stable for 20 months if stored at 2-8 C. After the cartridge pouch is opened, the test should be performed immediately. MATERIALS SUPPLIED : REF CFPC-23 Components of ichromaâ?¢ PCT Cartridge Box: - Cartridges 10 - ID Chip 1 - Instruction For Use 1 Box containing Detection Buffer tubes - Detection Buffer Tubes 10
Product Details: Number of Reactions(Preps)/Kit : 25 T Brand : Boditech Med Incorporated Sample Volume : 75 Microliter Sample : human serum/plasma Reaction Time : 15mins Cat No : 13010 Luteinizing Hormone (LH) Assessing and monitoring function of pituitary gland This test helps evaluate pituitary function by quantifying luteinizing hormone in the blood, to diagnose pituitary gland disease, and to determine congenitally or acquired gonadotropin dysfunction. INTENDED USE : ichroma LH is a fluorescence Immunoassay (FIA) for the quantitative determination of Luteinizing hormone (LH) in human serum/plasma. It is useful as an aid in management and monitoring of determination of evaluating fertility issues, function of reproductive organs (ovaries or testicles), or detection of the ovulation. For in vitro diagnostic use only. PRINCIPLE: The test uses a sandwich immunodetection method; the detector antibody in buffer binds to antigen in sample, forming antigen-antibody complexes, and migrates onto nitrocellulose matrix to be captured by the other immobilized-antibody on test strip. The more antigen in sample forms the more antigen-antibody complex and leads to stronger intensity of fluorescence signal on detector antibody, which is processed by instrument for ichromaâ?¢ tests to show LH concentration in sample. MATERIALS SUPPLIED: REF 13010 Components of ichroma LH Cartridge Box: - Cartridges 25 - ID Chip 1 - Instruction For Use 1 Box containing Detection Buffer Tubes - Detection Buffer Tubes 25.
Product Details: Number of Reactions(Preps)/Kit 30 Brand : CTK BioTech Result Time (Rapid Kits) :20-25 Min Sample Material :Serum / Plasma / Whole Blood Cat. No : R0061c The OnSite Dengue IgG/IgM 3.0 Combo Rapid Test is a lateral flow immunoassay for the simultaneous detection and differentiation of IgG and IgM antiâ??dengue virus (DEN1, 2, 3 and 4) in human serum, plasma or whole blood. Product Features: Utilizes recombinant chimeric dengue virus licensed from the US CDC Detects all four dengue serotypes IgM detection indicates recent infection IgG detection indicates recent or previous infections Each kit contains: Individually sealed foil pouches containing: One cassette device One desiccant 5 AUL Capillary tubes Sample diluent (REF SB-R0061, 5 mL/bottle) One package insert (instruction for use)
Product Details: Brand : Boditech Med Incorporated Size : 25 T Specimen : human serum/plasma Specimen volume : 50 Microliter Cat. No. : CFPC-47 INTENDED USE : ichromaâ?¢ Vitamin D is a fluorescence Immunoassay (FIA) for the quantitative determination of total 25(OH)D2/D3 level in human serum/plasma. It is useful as an aid in management and monitoring of regulating the concentration of calcium and phosphate in the bloodstream and promoting the healthy growth and remodeling of bone.For in vitro diagnostic use only. PRINCIPLE : The test uses a competitive immunodetection method. In this method, the target material in the sample binds to the fluorescence (FL)-labeled detection antibody in detection buffer, to form the complex as sample mixture. This complex is loaded to migrate onto the nitrocellulose matrix, where the covalent couple of 25(OH)D3 and bovine serum albumin (BSA) is immobilized on a test strip, and interferes with the binding of target material and FL-labeled antibody. If the more target material exists in blood, the less detection antibody is accumulated, resulting in the less fluorescence signal. STORAGE AND STABILITY : The cartridge is stable for 20 months (while sealed in an aluminum foil pouch) if stored at 4-30 C. The detection buffer dispensed in a vial is stable for 20 months if stored at 2-8 C. The releasing buffer dispensed in a vial is stable for 20 months if stored at 2-8 C. Opened detection buffer and releasing buffer are stable for 12 months at 2-8 C if kept capped in original container and free from contaminations. After the cartridge pouch is opened, the test should be performed immediately. MATERIALS SUPPLIED : REF CFPC-47Components of ichroma Vitamin D Cartridge Box:- Cartridges 25- Sample Mixing Tubes 25- ID Chip 1- Instruction For Use 1 Detection Buffer Vial (3 mL) 1 Releasing Buffer Vial (2 mL) 1
Product Details: Brand : Boditech Med Incorporated Size : 25 T Samples : Human whole blood/serum/ plasma Sample volume : 50 Microliter stored at 4 - 30 DegreeC Cat No : CFPC-65 Troponin I (Tn-I) Plus Early diagnosis of myocardial infarction with high sensitivity Troponin I (Tn-I) Plus can diagnose myocardial infarction and myocardial necrosis at an early stage with high sensitivity by accessing Tn-I level in the blood, thus can help prevent progression to more severe cases. INTENDED USE: ichroma Tn-I Plus is a Fluorescence Immunoassay (FIA) for the quantitative determination of cardiac troponin-I (Tn-I) in human whole blood/serum/plasma. It is useful as an aid in management and monitoring of acute myocardial infarction (AMI). For in vitro diagnostic use only. PRINCIPLE : The test uses a sandwich immunodetection method; the detector antibodies in buffer bind to antigens in the sample, forming antigen-antibody complexes, and migrate onto nitrocellulose matrix to be captured by the other immobilized-antibodies on test strip. More antigens in the sample will form more antigen-antibody complexes which lead to stronger fluorescence signal by detector antibodies, which is processed by instrument for ichromaâ?¢ tests to show Tn-I concentration in the sample. MATERIALS SUPPLIED : REF CFPC-65 Components of ichroma Tn-I Plus Cartridge Box: - Cartridge 25 - 50L Capillary tube 25 - ID chip 1 - Instruction for Use 1 Buffer Box For ichorma II - Detector (Capped with plastic lid) 25 - Diluent 1 For ichroma 50 - Detector (Sealed with aluminum foil) 25 - Diluent 1
Product Details: Brand : Boditech Med Incorporated Size : 25 T Samples : Human whole blood/ serum/ plasma/control Specimen volume : 10 Microliter stored at 4 - 30 DegreeC Cat No : CFPC-77 NT-proBNP Helping to diagnose heart diseases and evaluate the severity level BNP and NTproBNP are peptides that are continuously produced in the heart. When the muscles in the left ventricle over-stretch as in heart failure, the secretion of these peptides into blood increases. One may utilize the level of NTproBNP in blood to assess the cardiac event and its severity. Both of BNP and NTproBNP can be used to show different aspects of the heart failure. INTENDED USE: ichroma NT-proBNP is a fluorescence Immunoassay (FIA) for the quantitative determination of NT-proBNP in human whole blood/serum/plasma. It is useful as an aid in the diagnosis of persons suspected of having congestive heart failure. For in vitro diagnostic use only. PRINCIPLE : The test uses a sandwich immunodetection method; the detector antibodies in buffer bind to antigens in the sample, forming antigen-antibody complexes, and migrate onto the nitrocellulose matrix to be captured by the other immobilized-antibodies on test strip. More antigens in the sample will form more antigen-antibody complexes which lead to stronger fluorescence signal by detector antibodies, which is processed by instrument for ichromaâ?¢ tests to show NT-proBNP concentration in the sample. MATERIALS SUPPLIED : REF CFPC-77 Components of ichroma NT-proBNP Cartridge Box: - Cartridge 25 - ID Chip 1 - Instruction for Use 1 Buffer Box For ichroma - Detector tube 25 - Detector diluent 1 For ichromaâ?¢-50 - Detector tube 25 - Detector diluent 1
Product Details: Brand : Boditech Med Incorporated Size : 25 T Samples : human whole blood/serum/plasma Specimen volume : 5 Microliter stored at 4-30 C Cat No : CFPC-51 Anti-CCP Plus Supporting to distinguish and diagnose rheumatoid arthritis This test helps to diagnose and provide appropriate treatment for chronic systemic autoimmune diseases and rheumatism by quantifying Anti-CCP in the blood. INTENDED USE : ichroma Anti-CCP is a fluorescence Immunoassay (FIA) for the qualitative or semi-quantitative determination of human IgG autoantibodies to cyclic citrullinated peptides (CCP) in human whole blood/serum/plasma. It is useful as an aid in the diagnosis of rheumatoid arthritis (RA) in combination with other clinical and laboratory findings. For in vitro diagnostic use only. STORAGE AND STABILITY : The cartridge is stable for 20 months (while sealed in an aluminum foil pouch) if stored at 4-30 C. The detection buffer dispensed in a tube is stable for 20 months if stored at 2-8 C. After the cartridge pouch is opened, the test should be performed immediately. PRINCIPLE : A synthetic cyclic citrullinated peptide (CCP) is immobilized on a porous membrane. After a sample is added to the sample port, detection buffer, consisting of fluorescent conjugated polyclonal antibody to human IgG, is loaded to the buffer port. The more anti-CCP antibodies in sample forms the more the peptide antigen/anti-CCP antibodies complex and leads to stronger intensity of fluorescence signal on detector anti-human IgG, which is processed by instrument for ichroma tests to show anti-CCP level in sample. MATERIALS SUPPLIED : REF CFPC-51 Components of ichroma Anti-CCP Cartridge Box: - Cartridges 25 - Sample collectors 25 - ID Chip 1 - Instruction For Use 1 Box containing Detection Buffer Tubes - Detection Buffer Tubes 25
Product Details: Brand : Boditech Med Incorporated Size : 25 T Samples: human whole blood/serum/ plasma Specimen volume : 50 microliter stored at 4 - 30 C Cat No : CFPC-91 Total IgE Assessing to diagnose acute allergic diseases This test assesses IgE in blood to support diagnosing of acute allergic diseases. INTENDED USE : ichroma Total IgE is a fluorescence immunoassay (FIA) for the quantitative determination of total IgE in human whole blood/serum/ plasma. It is useful as an aid in diagnosis and management of allergic disease. For in vitro diagnostic use only. PRINCIPLE : The test uses a sandwich immunodetection method; the detector antibodies in buffer bind to antigens in the sample, forming antigen-antibody complexes, and migrates onto nitrocellulose matrix to be captured by the other immobilized-antibodies on test strip. More antigens in the sample will form more antigen-antibody complexes which lead to stronger fluorescence signal by detector antibodies, which is processed by instrument for ichroma tests to show total IgE concentration in the sample. MATERIALS SUPPLIED : REF CFPC-91 Components of ichroma Total IgE Cartridge Box: - Cartridge 25 - ID Chip 1 - Instruction for Use 1 Detection Buffer Box - Detection Buffer 25
Product Details: Brand : Boditech Med Incorporated Size ; : 25 T Samples : Human whole blood/plasma/control Specimen volume : 10 Microliter Storage : 4- 30 DegreeC Cat No : CFPC-25 D-Dimer Measuring D-dimer level in 12 mins The presence of D-dimer in blood indicates that thrombin has been formed and fibrin generated from fibrinogen in vivo as a result of activation of the coagulation system. This test measures the level in the blood to help assess the thrombotic state. INTENDED USE : ichroma D-Dimer is a fluorescence Immunoassay (FIA) for the quantitative determination of D-Dimer in human whole blood/plasma. It is useful as an aid in management and monitoring of post therapeutic evaluation of thromboembolic disease patients. For in vitro diagnostic use only. PRINCIPLE : The test uses a sandwich immunodetection method; the detector antibodies in buffer bind to antigens in the sample, forming antigen-antibody complexes, and migrate onto nitrocellulose matrix to be captured by the other immobilized-antibodies on test strip. More antigens in the sample will form more antigen-antibody complexes which lead to stronger fluorescence signal by detector antibodies, which is processed by instrument for ichromaâ?¢ tests to show D-Dimer concentration in the sample. MATERIALS SUPPLIED : REF CFPC-25 Components of ichroma D-Dimer Cartridge Box: - Cartridge 25 - ID chip 1 - Instruction for use 1 Box containing Detection Buffer tubes - Detection buffer 25
Product Details: Number of Reactions(Preps)/Kit : 25 T Brand : Boditech Med Incorporated Sample Volume : 75 Microliter Sample : serum/plasma/control Storage Temperature : 4-30 DegreeC. Cat No : CFPC-27 Prolactin (PRL) Assessing to diagnose hypothalamic impairments & pituitary disorders This test helps select and diagnose mammary gland development, infertility treatment and pituitary diseases by quantifying blood PRL. INTENDED USE : ichroma PRL is a fluorescence Immunoassay (FIA) for the quantitative determination of Prolactin (PRL) in human serum/plasma. It is useful as an aid in management and monitoring of hypothalamic-pituitary disorders. For in vitro diagnostic use only. PRINCIPLE: The test uses a sandwich immunodetection method; the detector antibody in buffer binds to antigen in sample, forming antigen-antibody complexes, and migrates onto nitrocellulose matrix to be captured by the other immobilized-antibody on test strip. The more antigen in sample forms the more antigenantibody complex and leads to stronger intensity of fluorescence signal on detector antibody, which is processed by instrument for ichromaâ?¢ tests to show PRL concentration in sample. MATERIALS SUPPLIEED : REF CFPC-27 Components of ichroma PRL Cartridge Box: - Cartridges 25 - ID Chip 1 - Instruction for Use 1 Detection Buffer Box: - Detection Buffer tubes 25
Product Details: Number of Reactions(Preps)/Kit : 25 T Brand : Boditech Med Incorporated Sample Volume : 10 Microliter Sample : Human whole blood/serum/ plasma/control Reaction Time : 3 mins Cat No : ichroma CRP-25 CRP Assessing to diagnose infection and inflammation This test can help with proper prescription and treatment by quickly and accurately measuring CRP with a finger-tip blood. INTENDED USE : ichroma CRP is a fluorescence Immunoassay (FIA) for the quantitative determination of CRP in human whole blood/serum/ plasma. It is useful as an aid in management and monitoring of autoimmune diseases and infectious processes, such as rheumatoid arthritis. For in vitro diagnostic use only. PRINCIPLE : The test uses a sandwich immunodetection method; the detector antibodies in buffer bind to antigens in the sample, forming antigen-antibody complexes, and migrate onto nitrocellulose matrix to be captured by the other immobilized-antibodies on test strip. More antigens in the sample will form more antigen-antibody complexes which lead to stronger fluorescence signal by detector antibodies, which is processed by instrument for ichromaâ?¢ tests to show CRP concentration in the sample. MATERIALS SUPPLIED : REF i-CHROMA CRP-25 Components of ichrom CRP Cartridge Box: - Cartridge 25 - ID Chip 1 - Instruction for Use 1 - Sample Collector 25 Box containing Detection Buffer - Detection buffer 25
Product Price: Rs 53,000 / Unit Product Details: Capacity(Litre per minute) 5 LPM Brand Philips Oxygen Concentration 93 +/- 3 % Sound Level 45 (typical) dB Weight (in kg) 14 kgs Dimension 58.4 cm H x 38.1 cm W x 24.1 cm D (23" H x 15" W x 9.5" D) Alarm Low Oxygen (82%) and Very Low Oxygen (70%) I Deal In New Only Input Voltage 120 +/- 10% VAC Input Frequency 60 Hz Until now, oxygen concentrators have been very similar - heavy, bulky, noisy, or requiring frequent maintenance. EverFlo from Respironics is a unique stationary concentrator that delivers what homecare providers want and patients deserve. Features: Lightweight for easy transport The EverFlo Oxygen concentrator weighs in at only 31 pounds, reducing shipping and storage costs and risk of injury. Compact design looks less like a medical machine EverFlo's ergonomic design takes up less space and doesn't draw as much attention. The Right Fit series focuses on patients' needs EverFlo is part of the Right Fit, a complete portfolio of oxygen products and programs inspired by patients and built for business. Low maintenance for reduced service costs No homecare provider filter change for two years. Patients do not ever have to change filters. Lower power consumption makes EverFlo patient-friendly The system uses less electricity and produces less heat. Humidifier Bottle Platform for extra flexibility The platform is designed to be compatible with all bottle styles and features an easy-to-use velcro closure. Recessed flow meter reduces accidental breakage Recessed flow meter reduces accidental breakage Oxygen purity indicator option for increased security EverFlo is available with or without oxygen purity indicator. This OPI (Oxygen Percentage Indicator) ultrasonically measures oxygen output as a purity indication.
Thermofisher Quantstudio 5 Real Time PCR System, 96 wells Product Details: Model Name/Number QuantStudio 5 Includes Desktop Brand Thermofisher Sample Capacity/Format 96 wells Volume Thermal Block Sample 0.2ml Block Format Non-Interchangeable Display Type Touch Screen Smaller foot print 27x50x40 cm CAT No : A28139 Features: Proven OptiFlex technology (6 decoupled channels/21 filter combinations with white LED) for trusted results User account management, locked workflow, and Pause features for greater control of experiment data Built-in software features to support compliance with 21 CFR Part 11 guidelines Secure cloud-based software provides increased accessibility and storage options Simplified instrument software with interactive touchscreen for greater ease of use The Applied Biosystems QuantStudio 5 Real-Time PCR System for Human Identification with tower computer is the latest addition to our human identification (HID) real-time PCR family of products. This instrument is designed for both new and experienced users who need a simple, reliable, and affordable real-time PCR system that doesnâ??t require compromise on performance or quality. When used with our latest advances in quantification chemistry and HID Real-Time PCR Analysis Software, this system offers a sensitive, robust solution for forensic DNA quantification. It also helps prepare laboratories for future quantification technologies. With maximum dye versatility, this HID solution offers accurate, trusted results in a small benchtop footprint
Product Details: Number of Reactions(Preps)/Kit 30T Brand CTK Biotech Result Time (Rapid Kits) 20mins Test Type Rapid Test CAT No : R0234C The OnSite Toxo IgG/IgM Combo Rapid Test is a lateral flow chromatographic immunoassay for the simultaneous detection and differentiation of IgG and IgM anti-Toxoplasma gondii (T. gondii) in human serum, plasma or whole blood.