Product Details:
Brand : Boditech Med Incorporated
Size : 25 T
Samples: human whole blood/serum/ plasma
Specimen volume : 50 microliter
stored at 4 - 30 C
Cat No : CFPC-91
Total IgE
Assessing to diagnose acute allergic diseases
This test assesses IgE in blood to support diagnosing of acute allergic diseases.
INTENDED USE :
ichroma Total IgE is a fluorescence immunoassay (FIA) for the quantitative determination of total IgE in human whole blood/serum/ plasma. It is useful as an aid in diagnosis and management of allergic disease.
For in vitro diagnostic use only.
PRINCIPLE :
The test uses a sandwich immunodetection method; the detector antibodies in buffer bind to antigens in the sample, forming antigen-antibody complexes, and migrates onto nitrocellulose matrix to be captured by the other immobilized-antibodies on test strip.
More antigens in the sample will form more antigen-antibody complexes which lead to stronger fluorescence signal by detector antibodies, which is processed by instrument for ichroma tests to show total IgE concentration in the sample.
MATERIALS SUPPLIED :
REF CFPC-91
Components of ichroma Total IgE
Cartridge Box:
- Cartridge 25
- ID Chip 1
- Instruction for Use 1
Detection Buffer Box
- Detection Buffer 25
Covid-19 Self Test Kit We are the authorized first vendor of ADTech! KFDA CE approved, FDA Pending Price : Negotiable Pre-Clinical Test Report Accuracy - In total samples 93.3% (14/15) - In positive samples 91.7% (11/12) 1. Pre-Clinical Test summary 1) Pre-clinical test is fulfilled by Domestic large clinical laboratory with ADTech COVID-19 IgM/IgG RAPID KIT 2) Tests are made by total 15 samples with 12 positive and 3 negative samples 3) Clinical Laboratory tested the sample with Immunofluorescence Analysis 2. Pre-clinical test result 1) Samples were tested by ADTech COVID-19 IgM/IgG RAPID KIT 2) Test result by ADTechs RAPID KIT - 4 negatives and 11 positives results in 15 samples 3) Comparison between Immunofluorescence analysis and ADTechs RAPID KIT - 14 test results are same(including negative and positive results) - 1 samples test result are different(Positive Negative by ADTech
As the world's largest condom maker, we also manufacture personal lubricants. We manufacture latex condoms that are made from premium quality natural rubber latex. Our condoms are designed with total reliability whereby each condom is electronically tested to provide maximum protection and safety. Every design is carefully engineered by our Research and Development team which comprises of industry experts and each variant is developed to create the ultimate pleasure and safety for consumers. All our lubricants are Class IIa medical devices which comply with the new EU MDR regulations in force since May 2021. Medical Device ingredients are pharmaceutical grade, whereas non-medical / cosmetic lubricants have no restrictions. All our lubricants are compatible with latex condoms and are all 100% paraben free. Our personal lubricants can be used up to 6 months after opening. Our personal lubricants also meet the stringent harmonized standards such as ASTM D7661, NF97-034 and the WHO guidelines. *MOQ Condoms from 3000 gross * MOQ Lubes from 10000 Tubes/bottles
Product Details: Brand : Boditech Med Incorporated Size : 25 T Samples : Human serum/plasma/ control Specimen volume : 75 Microliter stored at ; 4 - 30 DegreeC Cat No ; CFPC-44 T3 Assessing to diagnosis & to monitor thyroid diseases(T3) This test assesses the level of T3 in the blood to diagnose thyroid dysfunction, help to receive appropriate treatment, and help to confirm the treatment effect through periodic measurement. INTENDED USE : ichroma T3 is a fluorescence Immunoassay (FIA) for the quantitative determination of triiodothyronine (total T3) in human serum/plasma. It is useful as an aid in management and monitoring of determination of thyroid disorders. For in vitro diagnostic use only. PRINCIPLE : The test uses a competitive immunodetection method. In this method, the analyte in the sample binds to the fluorescence labeled (FL) detection antibody in detection buffer, to form the complex as sample mixture. This complex is loaded to migrate onto the nitrocellulose matrix, where the covalent couple of T3 and bovine serum albumin (BSA) is immobilized and interferes with the binding of analyte and fluorescence labeled (FL) antibody. If more analytes exist in the sample, less detection antibodies are accumulated, resulting in less fluorescence signal. MATERIALS SUPPLIED : REF CFPC-44 Components of ichroma T3 Cartridge Box: - Cartridge 25 - Detector tube 25 - Detector diluent 2 - ID chip 1 - Instruction for Use 1
Product Details: Brand : Boditech Med Incorporated Size : 25 T Specimen : Human serum/plasma/ control Specimen volume : 75 microliter stored at 4 - 30 DegreeC. Cat No : CFPC-26 T4 Assessing to diagnosis & to monitor thyroid diseases(T4) Thyroxine (T4) is a type of thyroid hormone. An abnormal amount of T4 may indicate thyroid disease. The T4 test measures total T4, including T4 bonded to protein and free T4. A T4 test will help determine what type of problem is affecting the thyroid. INTENDED USE : ichroma T4 is a fluorescence Immunoassay (FIA) for the quantitative determination of thyroxine (T4) in human serum/plasma. It is useful as an aid in management and monitoring of thyroid disorder. For in vitro diagnostic use only. PRINCIPLE : The test uses a competitive immunodetection method. In this method, the target material in the sample binds to the fluorescence (FL)-labeled detection antibody in detector, to form the complex as sample mixture. This complex is loaded to migrate onto the nitrocellulose matrix, where the covalent couple of T4 and bovine serum albumin (BSA) is immobilized on a test strip, and interferes with the binding of target material and FL-labeled antibody. If the more target material exists in blood, the less detection antibody is accumulated, resulting in the less fluorescence signal. MATERIALS SUPPLIED : REF CFPC-26 Components of ichroma T4 Cartridge Box: - Cartridges 25 - ID Chip 1 - Insert 1 - Detector tube (Granule) 25 - Detector diluent (5.5 mL) 1
Product Details: Brand ; Boditech Med Incorporated Size : 25 T Samples: human whole blood/serum /plasma Specimen volume human whole blood/serum/ plasma stored at 4-30 C Cat. No. : CFPC-66 Human Chorionic Gonadotropin (�²-hCG) Distinguish pregnancy and abnormal pregnancy The IhCG test can be used to confirm pregnancy, the age of the fetus, abnormal pregnancy (ectopic pregnancy), potential miscarriage, and down syndrome. INTENDED USE : ichroma -HCG Plus is a fluorescence Immunoassay (FIA) for the quantitative determination of -HCG in human whole blood/serum /plasma. It is useful as an aid in management and monitoring of beta human chorionic gonadotropin (hCG) level in human For in vitro diagnostic use only. PRINCIPLE : The test uses a sandwich immunodetection method; Dried antibodies in the detector tube, once diluted with the diluent, bind with antigens in the sample to form antigen-antibody complexes. These complexes then migrate through the nitrocellulose matrix and are captured by another sets of immobilized antibodies on the test line. The more antigens in the sample, the more antigen-antibody complexes, which leads to a stronger fluorescence signal. This signal then is interpreted by the reader to display the �²-HCG concentration in the sample. STORAGE AND STABILITY : The cartridge is stable for 20 months (while sealed in the original aluminum foil pouch) if stored at 4-30 C. The detector, diluent and sample diluent are stable for 20 months if stored at 2-8 C. After the cartridge pouch is opened, the test should be performed immediately. MATERIALS SUPPLIED : REF CFPC-66 Components of ichroma-HCG Plus Cartridge Box: - Cartridges 25 - ID Chip 1 - Instruction For Use 1 Buffer Box For ichorma II - Detectors (Capped with plastic lid) 25 - Diluent 1 For AFIAS-50 - Detectors (Sealed with aluminum foil) 25 - Diluent 1 Sample Diluent Box: - Sample Diluent Tubes 25
Product Details: Brand: Boditech Med Incorporated Size : 25 T Samples : human serum/plasma Specimen volume : 150 Microliter stored at 4 - 30 DegreeC. Cat. No : CFPC-22 Thyroid Stimulating Hormone (TSH) Diagnosing thyroid dysfunction One needs an adequate level of thyroid hormone. The excessive or insufficient level would cause various abnormalities in human physiology. The TSH test can deliver the required answer about the hormone level in 12 minutes with fingertip blood (US FDA 510k; AFIAS TSH). INTENDED USE : ichroma NT-proBNP is a fluorescence Immunoassay (FIA) for the quantitative determination of NT-proBNP in human whole blood/serum/plasma. It is useful as an aid in the diagnosis of persons suspected of having congestive heart failure. For in vitro diagnostic use only. PRINCIPLE : The test uses a sandwich immunodetection method; the detector antibodies in buffer bind to antigens in the sample, forming antigen-antibody complexes, and migrate onto the nitrocellulose matrix to be captured by the other immobilized-antibodies on test strip. More antigens in the sample will form more antigen-antibody complexes which lead to stronger fluorescence signal by detector antibodies, which is processed by instrument for ichromaâ?¢ tests to show NT-proBNP concentration in the sample. MATERIALS SUPPLIED : REF CFPC-77 Components of ichroma NT-proBNP Cartridge Box: - Cartridge 25 - ID Chip 1 - Instruction for Use 1 Buffer Box For ichroma II - Detector tube 25 - Detector diluent 1 For ichroma-50 - Detector tube 25 - Detector diluent 1
Product Details: Brand : Boditech Med Incorporated Size : 25 Test Samples : Whole blood Sample volume : 75 Microliter Cat No : CFPC-38 Storage Temperature ; 4 - 30 DegreeC HbA1c Assessing the level of glycated hemoglobin in the blood This test is certified by NGSP (National Glycohemoglobin Standardization Program). It helps diabetic diagnosis, treatment, and prognosis by measuring the glycated hemoglobin concentration (%) in a small amount of blood over the past 3 months. INTENDED USE ichroma HbA1c is a fluorescence Immunoassay (FIA) for the quantitative determination of HbA1c(Hemoglobin A1c) in human whole blood. It is useful as an aid in management and monitoring of the longterm glycemic status in patients with diabetes mellitus. For in vitro diagnostic use only. PRINCIPLE: The test uses a sandwich immunodetection method; the detector antibody in buffer binds to antigen in sample, forming antigen-antibody complexes, and migrates onto nitrocellulose matrix to be captured by the other immobilized-antibody on test strip. The more antigen in sample forms the more antigen-antibody complex and leads to stronger intensity of fluorescence signal on detector antibody. Instrument for ichromaâ?¢ tests displays the content of glycated hemoglobin in terms of percent of the total hemoglobin in blood.
Product Details: Brand : Boditech Med Incorporated Size : 25 T Samples : whole blood/serum/plasma Sample volume : 75 Microliter stored at 4 - 30 DegreeC Cat No i CHROMA PSA-25 Prostate Specific Antigen (PSA) Screening for the prostate cancer & monitoring the effects of the treatment This test helps in the early detection of prostate diseases such as enlarged prostate and prostatitis and prostate cancer by quantifying PSA in male blood, as well as observation of treatment effects and monitoring of recurrence.
Product Details: Brand ; Boditech Med Incorporated Size : 25 Test Samples : Serum/Plasma Recommended anticoagulant K2 EDTA, K3 EDTA, sodium heparin Storage Temperature : 4 - 30 DegreeC Cat No : CFPC-21 Progesterone Monitoring ovulation abnormalities and predicting miscarriage & ectopic pregnancy The progesterone test kit measures the level of progesterone in the blood. The progesterone test alone is not enough to diagnose a particular problem. But the result may help provide answers to causes of infertility, risk of miscarriage, ovulation, and ectopic pregnancy. PRINCIPLE : The test uses a competitive immunodetection method. In this method, the analyte in the sample binds to the fluorescence labeled (FL) detection antibody in detection buffer, to form the complex as sample mixture. This complex is loaded to migrate onto the nitrocellulose matrix, where the covalent couple of progesterone and bovine serum albumin (BSA) is immobilized, and interferes with the binding of analyte and fluorescence labeled (FL) antibody. If more analytes exist in the sample, less detection antibodies are accumulated, resulting in less fluorescence signal.