Bhd6 mini circuit breaker BH-D6 mini circuit breaker is mainly suitable for overload and short circuit protection. It can also be used for an unfrequently switchover of the circuit and illumination under normal conditions.
C45n mini circuit breaker
C45n series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short-circuit in the system. The product is novel in structure, light in weight, reliable and excellent in performance. Its frame and parts adopt plastics of high fire-resistant and shock- proof. The product, with long life, is mainly used in ac 50hz/60hz single-pole 240v or two, three, four- pole 415v circuit for overload and short-circuit prot- ection as well as for unfrequent on-and-off switching electric equipment and lighting circuit in normal case. The products comply with iec 898 & bs 3871.
Mini circuit breaker (1)inb2 (dz47) high-breaking mini circuit breaker The product is mainly used in ac 50/60hz. Voltage up to 400v circuit for overload and short-circuit protection as well as for unfrequent on-and off switching electric equipment and lighting circuit in normal case. The items comply with iec 60898&gb 10963. Rated voltage: 230v, 230/400, 400 v Pole number: 1, 2 ; 1, 2 ; 2, 3, 4 Rated current: 6, 10, 16, 20, 25, 32, 40, 50, 63 a (2)inb1-63 mini circuit breaker The items comply with iec 60898&gb 10963. It is mainly used for overload and short circuit protection in the circuit of ac 50/60hz, rated voltage of single pole up to 230v, two, three or four pole up to 400v. It can also be used for infrequent switch over of the circuit and illumination under normal conditions. (3)inb2-32 mini circuit breaker The items are used in ac 50hz or 60hz, 230v single phase dwelling house circuit for overload and short-circuit protection. The nature wire and live wire can be cut off synchronously to protect the life and avoid the fire. The items comply with iec60898&gb10963. Connection: rigid conductor 16mm2 Flexible conductor 10mm2 Rated voltage: 230v Pole number: 1p+n Rated current: 6, 10, 16, 20, 25, 32 a Breaking capacity: 4500a (4)bh(dz12-63) series mini circuit breaker The items are used in ac circuits 50hz forprotection of overload, short circuit and for circuit change-over in lighting system. Pole number: 1p 2p 3p Rated current: 6, 10, 16, 20, 32, 40, 50, 63 a Rated voltage: ac 120/230, 230/400 v Zhejiang inte industrial electric co., ltd. Was founded in 1984 and is iso 9001: 2000 certified. We mainly manufacture circuit breaker, thermal protector, thermostat and counter etc. Electrical and electronic equipments. Some of our products have got ccc, ul, vde, ce, saso approval. Leave factory packing
Ccb531n circuit breaker Vde approval circuit breaker Manufactured according to iec/en60898, gb10693. Pole:1p-n Rated voltage:230v~ Rated current:6, 10, 16, 20, 25, 32a Tripping characteristic: "b" "c" Breaking capacity: 6ka/ class3 12pcs/box. 120pcs/carton.
Pole number: 1,2,3P Rated voltage: 120/240V Rated current: 10,15,20,25,30,40,50,60A Interrupting Capability: 10KA Standard: US standard
Earth leakage circuit breaker The elcb is micro controller based with shock guard which continuously displays all the parameters and with inbuilt seven segment display and indicates the reason for tripping. Dimensions 17.5x13.5x8 cm Weight 1.5kg approx
Vacuum circuit breaker Our products are inexpensive and have super quality. All products have passed the iso9001 international quality certification, some model passed europe certificate for e-mark.. We can provide all sorts of products with advantage in technology, quality and cost.
Description IC REG CTRLR DDR 2OUT 20WQFN Manufacturer Standard Lead Time 12 Weeks Detailed Description D-CAP Controller, DDR Voltage Regulator IC 2 Output 20-WQFN (3x3)
Description IC GATE AND 1CH 2-INP 5TSSOP Detailed Description AND Gate IC 1 Channel 5-TSSOP
TF Electronic Components Sell Integrated Circuits ICs, Diodes, Capacitors, Resistor, Transistor, Relays, Connectors, Semiconductors, and Other Components. AD8662ARZ M63015FP SA571DR2G ADAU7002ACBZ-R7 LM1972MX/NOPB DRV135UA/2K5 OPA2134PAG4 DRV134PA DRV134UA DRV135UA SRC4190IDBR SI8445BB-D-IS1R SI8244BB-D-IS1R CS4398K-CZZ CS8416K-CZZR SRC4392IPFBR MUSES72320V-TE2 PGA2310UA/1K NJM2761RB2-TE1 LM1971MX/NOPB DIX9211PTR DIT4096IPW ADAU7002ACBZ-RL DIR9001PWR NJU72343V-TE1
TF Electronic Components Sell Integrated Circuits ICs, Diodes, Capacitors, Resistor, Transistor, Relays, Connectors, Semiconductors, and Other Components. AD8662ARZ M63015FP SA571DR2G ADAU7002ACBZ-R7 LM1972MX/NOPB DRV135UA/2K5 OPA2134PAG4 DRV134PA DRV134UA DRV135UA SRC4190IDBR SI8445BB-D-IS1R SI8244BB-D-IS1R CS4398K-CZZ CS8416K-CZZR SRC4392IPFBR MUSES72320V-TE2 PGA2310UA/1K NJM2761RB2-TE1 LM1971MX/NOPB DIX9211PTR DIT4096IPW ADAU7002ACBZ-RL DIR9001PWR NJU72343V-TE1
Imported Circuit Breaker
original have in stock
For electrical maintenance and installation, it can take necessary power off, insulation protection measures to protect your safety.
Pcb/auto Parts/ Circuit Breaker
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the power system. Safe operation mechanical characteristic parameters are one of the important parameters to judge the performance of the circuit breaker. Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. Its main feature is that in addition to meeting the dynamic characteristics test of the general high-voltage switch on the market it also satisfies the test of Siemens graphite contact switch and can reliably test the dynamic resistance waveform of the three fractures of the graphite contact switch. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty. Product nicknameï¼?High-voltage switch mechanical characteristic tester switch mechanical characteristic tester high-voltage switch comprehensive tester circuit breaker dynamic characteristic tester circuit breaker mechanical characteristic tester circuit breaker comprehensive tester high-voltage switch time characteristic tester high-voltage switch characteristic test Instrument switch characteristic tester circuit breaker tester switch mechanical characteristic tester switch parameter tester Breaker Analyzer
With the development of society people have higher and higher requirements for the safety and reliability of power consumption. High-voltage circuit breakers have the dual tasks of control and protection in the power system. The performance of the power circuit is directly related to the safe operation of the power system. The mechanical characteristic parameter is one of the important parameters for judging the performance of the circuit breaker. The Breaker Analyzer is a special instrument developed by the company to meet the needs of various high-voltage switch operating characteristics tests. It can accurately measure low-oil multi-oil vacuum sulfur hexafluoride and other high-voltage circuit breakers of various voltage levels. Mechanical dynamic characteristics parameters. The instrument adopts large screen display Chinese characters prompt man-machine dialogue mode operation Chinese characters display results and printouts with intelligent multi-function accurate data strong anti-interference simple operation small size light weight and beautiful beauty.
This instrument is designed for testing DC circuit breakers at rated current of 1A-500A. 1. The instrument can be used separately or linked to PC. 2. 320*240 LCD screen thermal printer interactive keyboard operation and intelligent operation system. 3. Power electronics controlling technique has been adopted to output high current with high speed high precision and continuous adjustability. 4. Current range can be automatically switched by multiple high precision sensors.14 digit AD acquisition chip of high capacity. 5. Automatic data storage. Be capable of saving 200 testing results which will not lose in power failure. 6. Two options: ampere-second characteristic test or through current characteristic test. 7. When linking to PC it is available to do following operations such as controlling the instrument data importing data saving data report and data graph generation. 8. Protection functions for overheat over-current and over voltage. 9. Anti-interference capacity and good EMC(electromagnetic compatibility).
This instrument is designed for testing DC circuit breakers at rated current of 1A-500A. 1. The instrument can be used separately or linked to PC. 2. 320*240 LCD screen thermal printer interactive keyboard operation and intelligent operation system. 3. Power electronics controlling technique has been adopted to output high current with high speed high precision and continuous adjustability. 4. Current range can be automatically switched by multiple high precision sensors.14 digit AD acquisition chip of high capacity. 5. Automatic data storage. Be capable of saving 200 testing results which will not lose in power failure. 6. Two options: ampere-second characteristic test or through current characteristic test. 7. When linking to PC it is available to do following operations such as controlling the instrument data importing data saving data report and data graph generation. 8. Protection functions for overheat over-current and over voltage. 9. Anti-interference capacity and good EMC(electromagnetic compatibility).