With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non-magnetic metal substrate. Five types of probes (F400, F1, F10, N1, CN02) are available for different application. F10 probe measures up to 10mm. Two measuring modes: single or continuous, changeable. Two calibration methods can be applied to the gauge; And the system error of the probe can be corrected with the basic probe calibration method. Measured values and user information are shown on a large, easy-to-read LCD. A display back light ensures easy reading of screen data in poorly-lit conditions. Measuring status indicator showing the measuring status. n. Measuring Principles The gauge adopts two thickness-measuring methods: magnetic induction method and eddy current method. insulating coatings on all non-ferrous metals and on austenitic stainless steels, e.g. paint, anodizing coatings, ceramics, etc. applied on aluminum, copper, zinc die-casting, brass, etc. Working Conditions Working temperature£º -10¡æ¡«£«50¡æ; Storage temperature£º-30¡æ¡«£«60¡æ; Relative humidity: ¡Ü90£¥; The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust. Configuration No. Item Quantity Remarks Standard Config. 1 Main unit 1 2 Probe 1 F1 or N1 3 Calibration Foils 5 PCS 4 Zero plate 1 Iron or Aluminum 5 Instrument case 1 6 Manual 1 7 Alkaline Battery 2 PCS AA size 8 Optional Config. 9 Other type of probes 10 DataPro software 1 On CD 11 USB cable 1 bjxhhd-tech.com sinharef@126.com
With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non-magnetic metal substrate. Five types of probes (F400, F1, F10, N1, CN02) are available for different application. F10 probe measures up to 10mm. Two measuring modes: single or continuous, changeable. Two calibration methods can be applied to the gauge; And the system error of the probe can be corrected with the basic probe calibration method. Measured values and user information are shown on a large, easy-to-read LCD. A display back light ensures easy reading of screen data in poorly-lit conditions. Measuring status indicator showing the measuring status. The gauges¡¯ user-friendly measuring system permits automatic storage of up to 1000 readings in one memory matrix for later statistical evaluation. Measuring Principles The gauge adopts two thickness-measuring methods: magnetic induction method and eddy current method. insulating coatings on all non-ferrous metals and on austenitic stainless steels, e.g. paint, anodizing coatings, ceramics, etc. applied on aluminum, copper, zinc die-casting, brass, etc. Working Conditions Working temperature£º -10¡æ¡«£«50¡æ; Storage temperature£º-30¡æ¡«£«60¡æ; Relative humidity: ¡Ü90£¥; The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust. Configuration No. Item Quantity Remarks Standard Config. 1 Main unit 1 2 Probe 1 F1 or N1 3 Calibration Foils 5 PCS 4 Zero plate 1 Iron or Aluminum 5 Instrument case 1 6 Manual 1 7 Alkaline Battery 2 PCS AA size 8 Optional Config. 9 Other type of probes 10 DataPro software 1 On CD 11 USB cable 1
This Micro Vickers hardness tester is a precise testing system suitable for hardness analysis of metallic specimens in metallography laboratories or production environments. Model No. 900-391A Vickers Hardness Tester Includes Video cam, adapter and manual measurement softwar Model No. 900-391B Vickers Hardness Tester Includes Video cam, adapter and Auto-Measurement software Model No. 900-391C Vickers Hardness Tester Includes Video cam, adapter and Turret control w manual measurement software Model No. 900-391D Vickers Hardness Tester Includes Video cam, adapter and Turret control w Auto-Measurement software Model No. 900-391E Vickers Hardness Tester
State of the art, digital portable hardness tester is designed to test the hardness of large hard metal parts. Loaded with useful functions only found on high priced models the PHT-1800 portable hardness tester is clearly setting a new industry standard by being the most accurate, economically priced portable hardness tester on the market today. Fast test speeds coupled with memory and output, this unit is a hand down winner whether you are out in the field or in the QC shop. The PHT-1800 portable hardness tester can perform tests that easily convert to the most popular hardness scales, including Rockwell, Brinell, Vickers, Shore, etc.
The phase ii ultrasonic portable hardness testers are capable of measuring the surface hardness of a broad variety of metals on flat, round, thin or large surfaces. Unlike the standard dynamic hardness testers, these "state-of-the-art" portable hardness testers incorporate "ultrasonic uci" technology, which enables the hardness testing of very thin and small workpieces, which otherwise could not be tested accurately using a portable device. Non-destructive in it's function, these hardness testers allow for the testing of highly sensitive or finished parts that previously could not be tested in an operational setting. The non-destructive (ndt) feature of these hardness testers allow the operator to accurately test parts without causing physical or structural damage that would normally lead to disposal or refinish of operators part. That translates into less scrap parts/ lower mfg costs due to necessary inspections.
Hareness tester, rougness tester, ultrasonic thickness gauge.
20 years NDT experience,ISO, CE & RoHS certificated, this is how we keep superior quality and competitive offers for global valued customers Display Type:2.4'' color OLED, 320�240 pixels, contrast 10,000:1 Operating Principle:Pulse echo with dual elements transducers Measuring Range: 0.02'' to 20.00'' (depends on material, probe and surface condition) Measuring Resolution:selectable 0.001'', 0.01'' Units:Inch or Millimeter Rectify Mode:RF+, RF-, HALF+, HALF-, FULL Display Mode:Normal, Minimum/Maximum capture, DIFF/RR%, A-Scan, B-Scan V-Path Correction:Automatic Update Rate: 4Hz, 8Hz or 16Hz Material Velocity Range:0.0197 to 0.3939 in/μs Languages:Chinese, English, Japanese,French, German Alarm Settings:Minimum and Maximum alarms. Range of 0.010'' to 20.00''. Dynamic waveform color change on alarm Operating Time:Approximately 40 hours with two AA batteries Instrument Shut-off: ALWAYS ON or AUTO OFF after 5, 10, 20 minutes of inactivity Operating Temperature: 14°F to 122°F Application Software: UmView Software for transmission,storage,analysis and documents editing Size: 6'' x 3'' x 1.5''
Portalbe hardness tester, bench hardness tester, durometer, ultrasonic thickness gauges, coating thickness gauges, roughness gauges.
OUTER LAYER: Type: Spun-bonded Material: 100% polypropylene Thickness: 25 - 28 GSM Characteristics: Hydrophobic Colour: Blue Other colours on request and subject to MOQ requirements MIDDLE LAYER: Type: Spun-bonded Material: 100% Melt-Blown Thickness: 25 - 28 GSM Characteristics: Electrostatic & Hydrophobic Colour: White INNER LAYER: Type: Spun-bonded Material: 100% polypropylene Thickness: 25 - 28 GSM Characteristics: Hydrophobic / Hydrophilic Colour: White EARLOOP: Material: 70% Polyester & 30% polyurethane Diameter: 3 mm Length: 175-180 mm Welding: Ultrasonic NOSE BRIDGE: Type: Double Wire Material: Aluminum Width: 3 mm Coating: Plastic Length: 100 mm
Supported by an industrious team of professionals, we are engaged in manufacturing Vertical Autoclave. The Vertical Autoclave, are manufactured, as per the industrial norms. Known for the high performance, the Vertical Autoclave, provided by us, have great demand across the global market. We provide the Vertical Autoclave in varied technical specifications to meet the diverse needs of the industries. Features ,Vertical - Model ,Useful for sterilization ,Double walled in construction ,Inner made of thick gauges stainless steel with argon welding ,Outer made of thick gauge stainless steel with 3 Nos. metal casting legs ,Foot lifting facility for opening of lid ,Silicon Gasket to minimize the heat loss ,Stainless Steel made wing nuts for tightening of lid ,Selection of Regular, Semi - Automatic & Fully Automatic ,Solid State Digital Temperature Controller with timer
Product Name: Long Sleeve Knitted Sweater Pullover Sweater MOQ: 50 Packing: 1 PC/Opp Bag OEM: Custom Made Service Category: Sweater Feature: Breathable Gauge: 12 GG Material: Spandex / Cotton Technics: Computer Knitted Item Type: Shrug Clothing Length: Regular Pattern Type: NONE Sleeve Style: Regular Collar: O-Neck Thickness: Thin Sleeve Length(cm): Full Decoration: None Style: Casual, Pullover Keyword: women's long sweater Package: each piece in one pp bag Payment: Trade Assurance
Moisture 3.5%-4.5%, Thickness: 103-110 um Surface roughness ts ml/min: 75-175 Surface roughness bs ml/min: 100-200 Bending stiffness md:>110 mn Bending stiffness cd:>50 mn Opacity: 95 min Cie whiteness: 167 Cobb test: 27-33 g/m2 27-33 Suitable for: Stay flat after copying Leave no dust in the copy-machine Nice appearance-white and clean Nice touch-smooth and bulky No see through-print both sides Guaranteed for trouble-free operation. Capability: high speed copying100ppm, laser Capable: inkjet capable, fax capable. High performance for both sides printing/copying 500 sheets per ream 5 reams per box 1560 boxes per 20 ft container(with pallet) 1600 boxes per 20ft container( without pallet) 7800 reams total in one 20fcl( with pallet) 8000 reams total in one 20fcl( without pallet We can also pack based on the customer requirements
1. HMS 1 - ISRI code 200: heavy melting steel, Wrought iron and steel scrap of varying thickness. Individual pieces shall be cut as demanded by buyer but must be prepared in a manner to insure compact charging. 2. HMS 1 - ISRI code 201,202: heavy melting steel - wrought iron or steel scrap . 3. HMS 2 - ISRI code 203: heavy melting steel. Wrought iron or steel scrap, black and galvanized - include material not suitable as no.1 heavy melting steel. Prepared in a manner to ensure compact charging. HMS 2 - ISRI code 204: same as ISRI 203. 4. HMS 2 - ISRI code 205: same asISRI 204 but free of sheet iron or thin-gauged material. HMS 2 - ISRI code 206: same as ISRI 204. Packing shall be in 20 or 40 foot containers only.
1.Multi function rebar detector = rebar locator + rebar corrosion detector; an economical and convenient device; 2.This model features the worldâ??s first wireless onsite data transfer function for such a device and remote management is also available; 3.Data can be stored on a usb-thumb drive, great for field work; 4.This device can generate rebar distribution map and rebar corrosion potential contour graph; 5.Powerful professional analysis-process software allows for the automatic generation of test reports.
Canneed MBT-200 Hall Effect Thickness Gauge (Magnetic Bottle Thickness Gauge)¡± is a refined portable thickness gauge. It is used to measure the thickness of nonmagnetic material, such as plastic, glass, synthetics, aluminum and titanium, etc. The measurement accuracy is undistorted by the samples shapes. MBT-200 is based on the theory of Hall Effect. For test, place the steel ball on one side of the sample and the probe on the other side. The Hall Effect sensor on the probe measures the distance from the probe tip to the steel ball. The calculator will display the real thickness readings. Attributes: * Adopted non-destructive test method. With quick measurement for spot thickness on area where accurate measurement of corners, small radii, or complex shapes are required * Display the real time thickness readings and automatically capture the minimum thickness * A standard instrument in plastic packaging industry * Rapid measurement, up to 16 times per second * Accuracy: 1% * It stores 95,000 thickness readings as the internal data record. Technical Data: Steel Ball Dia. 1/16 (1.59mm) 1/8 (3.18mm) 3/16 (4.76mm) Thickness Range (Standard Probe) .0001-.0900 (.001-2.590mm) .0001-.0900 (.001-4.570mm) .0001-.0900 (.001-6.350mm) Calibration Graduation (Accuracy) 3%* 2%* 1%* The accuracy to be subject to the thickness range. Please refer to the manual for detailed specifications: Scanning Speed : up to 16 times (Optional) Minimum Mode : rapid search and minimum thickness display Resolution : 0.01 mm or 0.001 mm (0.001 or 0.0001 ) Display : LCD display, can display the real time reading, minimum reading, alarm status and data document information at the same time. Data Recorder : It stores, reviews, eliminates and transfers 95,000 thickness readings and documents in numeric identifying code. Data Output : RS-232 serial port On-site Report: : Minimum value, maximum value, SD Calibration : Two-point standard calibration, or multi-calibration up to 5 reference points Deviation Mode : Display the difference between the actual thickness and the pre-set reference thickness Alarm Mode : Programmable, vocal and indication-visible high and low alarm setting points Power : 100/120/220/240 VAC, 48-62 Hz Battery : Rechargeable Nickel-Cadmium battery. According to the working status of background light, it can last for 8-16 hours. Charging time is 2 hours. Metric/Imperial Unit : Inch or mm for option Language : English Working Temperature : 0 - +50¡æ Dimension : 9.375*5.45*1.5 (238*138*38mm) N.W. : 3.2 kg Standard Configuration: MBT-200 Hall Effect Thickness Gauge includes: * Standard probe * Probe stand * Probe cable * User manual * Nickel-made rechargeable battery * External power supply and charger * Steel ball and calibration set, including Steel ball (with diameters of 1/16 , 1/8 , 3/16 ) Calibration block: 0.010 /0.25 mm, 0.04 /1 mm, 0.160 /4 mm (If pre-test sample is over 0.160 /4 mm, accessories are optional by order.).
1.Better than 1% accuracy 2. 0.2% of repeatability 3. 4¡á16 english letters lcd display 4. Operate with clamp on transducers 5 rs 232 interface or 1-channel isolated oct output 6. Pipe diameters from 15mm to 6000mm 7. Ni-mh battery operation of over 12 h 8.90~230vac power supply 9. Internal data logger 10. Bilingual interface in chinese and englis. 1setone carton
Ultrasonic flow meter, ultrasonic level meter, level meter, ultrasonic level meter, coating thickness gauge, ultrasonic thickness gauge, hand held ultrasonic flow meter, electromagnetic flow meter, flowmeters.
1.Thickness measurement using both Magnetic Method and Eddy Current Method to measure the non-magnetic coating on a magnetic metal substrate, or non-conductive coating on non-magnetic metal substrate. 2.Single-point or two-point method could be used to correct probe system deviation, in order to ensure the accuracy of the device in the process of measuring. 3.Fast automatic identification of iron and non-iron substrate. 4.Power voltage indicator. 5.Speaker beep while operating. 6.Power-off automatically when idle; manually power-off available. 7.Negative display function to ensure the accuracy of zero point calibration. 8.Ultra-low power consumption, less than 10 μA in standby mode. z
Portable leeb hardness testers, ultrasonic thickness gauges, ultrasonic flaw detector, coating thickness gauges, ultrasonic flow meters, ndt equipment, testing instruments, ultrasonic probes/transducers.
Metal Sheet Specifications Overall Thickness: At least. Gauge Thickness: At least. No more than. ... Overall Width / OD: At least. Overall Length: At least. Tensile Strength (UTS, Break): At least. No more than. ... Yield Strength (YS): At least. No more than. ... Elongation: At least. No more than. ... Tensile Modulus (E): At least. No more than.