Application :- This is a premium product of electrical wires from \'JPCL\'. These cables are ideal for wiring in residential and commercial complexes, high-rise buildings, hotels, hospitals, schools, colleges, etc. (where the density of people is high). During a fire, these cables not only emit less smoke and toxic hydrochloric acid gas but also retard the spread of fire enabling those trapped inside to escape safely. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables have low conductor resistance resulting in power saving. These wires are insulated with a special grade PVC compound formulated and manufactured in-house only. The insulation is far superior in terms of critical oxygen and temperature index as well as in light transmission and acid gas generation. The skin coloration offers high insulation resistance and long life. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.75, 1.00, 1.50, 2.50, 4.00 and 6.00 Sq. mm Color Codes : Red, Yellow, Blue, Black and Green (For Earthing) Specification : IS:694 Packing : In 90 meter coils in attractive cartons
Temperature sensor deviates from simplistic ON/OFF thermostatic mechanisms which control a residential hot water heating operation to extremely delicate semiconductor types that can manage multiple means of administration stove factories.
Bonny light crude oil, blco, agricultural commodities, en590, jet fuel, jet a1, lco, jet a1, jp 54, en590 10ppm, 50ppm, 500ppm, gasoil d2, d6, lng, lpg, urea, petcoke, octane, automotive gas oil, ago & others.
Performance Sensitivity na/ppm at 2ppm co 420 to 650 Response time t90 (s) from zero to 10ppm co < 25 Zero current na in zero air at 20°c +30 to -130 Noise* ±2 standard deviations (ppb equivalent) 4 Range ppm limit of performance warranty 1000 Linearity ppb co error at full scale, linear at zero, 500ppm co 20 to 35 Overgas limit maximum ppm for stable response to gas pulse 2000 * tested with alphasense isb low noise circuit Environmental Sensitivity @ -20°c (% output @ -20°c/output @ 20°c) @ 5ppm co 40 to 70 Sensitivity @ 50°c (% output @ 50°c/output @ 20°c) @ 5ppm co 110 to 125 Zero @ -20°c na -30 to +30 Zero @ 50°c na -50 to -200 Cross sensitivity Filter capacity ppm·hrs h2s 250, 000 H2s sensitivity % measured gas @ 5ppm h2s < 1 No2 sensitivity % measured gas @ 5ppm no2 < 1 Cl2 sensitivity % measured gas @ 5ppm cl2 < 1 No sensitivity % measured gas @ 5ppm no < -3 So2 sensitivity % measured gas @ 5ppm so2 < 0.1 H2 sensitivity % measured gas @ 100ppm h2 at 20oc < 10 C2h4 sensitivity % measured gas @ 100ppm c2h4 < 1 Nh3 sensitivity % measured gas @ 20ppm nh3 < 0.1 Key temperature range °c -30 to 50 Specifications Pressure range kpa 80 to 120 Humidity range % rh continuous 15 to 90 Storage period months @ 3 to 20°c (stored in sealed pot) 6 Load resistor o (isb circuit is recommended) 33 to 100 Weight g < 13 Isweek provide smoke, gas, humidity&temperature, uv, fluid or other kinds of sensors More details welcome to inquiry: skype:isweek_laura
Gross Calorific Value (GCV) KWh/Nm3 11.131-12.647 LNG Density Kg/m3 430-478 Molecular Weight Kg/Kmol 16.52 - 18.88 Methane % mol 85.0 min 97.0 max LNG stands for Liquefied Natural Gas, which is natural gas that has been cooled to a very low temperature (-162°C or -260°F) and condensed into a liquid state. The process of liquefaction reduces the volume of natural gas by around 600 times, making it easier and more cost-effective to transport and store, particularly over long distances. LNG is odorless, colorless, and non-toxic. It is typically transported in specialized cryogenic tanker ships, and upon reaching its destination, it can be regasified back into its gaseous state for distribution through pipelines to consumers. LNG is used for a variety of purposes, including heating and electricity generation in residential, commercial, and industrial settings, as well as fuel for transportation, particularly in heavy-duty vehicles like trucks, ships, and buses.
Granular activated carbons are made from rigid raw materials, giving the necessary hardness to avoid excessive losses due to attrition and handling. They present large internal surface of pore structure, ensuring high adsorption power in specific purposes and uses. They are used in fixed or moving beds as columns where the liquid or gas passes through and gets purified. They can be used in liquid or gas phase continous adsorption process and offer unusual economy in cases where carbon regeneration is favorable. In liquid phase applications they remove colloids and organic substances that give undesirable odors, colors and taste to the products. They are efficiently used for water dechlorination in processes which require super chlorination as well as the removal of organic substances from the water. In vapor phase application they participate in the solvent recovery, adsorption of colors, purification of carbon di-oxide and catalyst support. They are also used to reduce the COD and BOD in effluent waste water. Granular activated carbon is produced from coconut shell charcoal by the process of steam activation. The coconut shell charcoal is fed into the rotary kiln and activated by steam at high temperatures resulting in the evaporation of impurities and opening up of pores on the surface. The resultant big particles are then crushed and sieved to get the desired particle size. Our main grades of granular activated carbon are given as under. We can customize the iodine value as well as the particle size according to your requirements
Granular activated carbons are made from rigid raw materials, giving the necessary hardness to avoid excessive losses due to attrition and handling. They present large internal surface of pore structure, ensuring high adsorption power in specific purposes and uses. They are used in fixed or moving beds as columns where the liquid or gas passes through and gets purified. They can be used in liquid or gas phase continous adsorption process and offer unusual economy in cases where carbon regeneration is favorable. In liquid phase applications they remove colloids and organic substances that give undesirable odors, colors and taste to the products. They are efficiently used for water dechlorination in processes which require super chlorination as well as the removal of organic substances from the water. In vapor phase application they participate in the solvent recovery, adsorption of colors, purification of carbon di-oxide and catalyst support. They are also used to reduce the COD and BOD in effluent waste water. Granular activated carbon is produced from coconut shell charcoal by the process of steam activation. The coconut shell charcoal is fed into the rotary kiln and activated by steam at high temperatures resulting in the evaporation of impurities and opening up of pores on the surface. The resultant big particles are then crushed and sieved to get the desired particle size. Our main grades of granular activated carbon are given as under. We can customize the iodine value as well as the particle size according to your requirements
Product name 10TP583T operating temperature - 20 c to + 100 cpackage / case to-18 brand semitec mounting style through hole detectivity d-star at 500 f 14.7e7 cm hz1/2 / welement size1.05 mm x 1.05 mm noise equivalent power - nep2.2 nw/hz 1/2 photo sensitivity15 v/w height 2.85 mm length5.6 mm operating temperature range- 20 c to + 100 c
Type:Temperature Sensor Car Make:MITSUBISHI OE NO.:MC850070;31390-00100 Place of Origin:Zhejiang, China (Mainland) Brand Name:ANT Model Number:CTS-041 Warranty:12 Months Sensor Type:Water Temperature Sensor 1OE NO.::MC850070 2OE NO.::31390-00100 Payment:Union.Paypal TT Shipping Term:DHL FEDEX EMS UPS Packing:Neutral Packing Quality:High-Quality Size:OEM Size
The coolant temperature sensor consists of a negative temperature coefficient thermistor that is very sensitive to temperature changes. When the engine coolant temperature gradually increased, Thermistor resistance will gradually decline, On the contrary increases, when the engine coolant temperature changes, the output voltage of the sensor also changes accordingly. Engine coolant temperature sensor elongated head contact with the cooling liquid, the temperature of the coolant is detected by the change of the resistance value, and this signal is sent to the ECU,Used to detect the engine coolant temperature. The ECU corrects the fuel injection time and the ignition time after receiving the temperature signal. The normal use of the coolant temperature sensor is -30 ° C to 120 ° C,The corresponding output voltage is 0.3V ~ 4.7V.When the ECU detects an output voltage signal beyond this range,You can determine the sensor circuit failure. Car intake air temperature sensor (IATS) Automotive coolant temperature sensor (CTS) automobile exhaust gas temperature sensor (Ex-haust Air Temperature Sensor, EATS) car was NTC thermistor / temperature sensor Car temperature sensor,Respectively, water temperature sensor,Exhaust | intake air temperature sensor,These types of sensors are thermistors with the same characteristics,The temperature coefficient is negative temperature coefficient.The water temperature sensor is mounted on the engine cooling water passage,Its role is to detect the engine cooling water temperature,The water temperature sensor housing is fully enclosed,Use the change of resistance value to detect water temperature.The signal temperature value generated by the water temperature sensor is input to the ECU,ECU according to the cooling water temperature ignition control,Correction fuel injection amount to real-time control of the engine,To ensure the normal operation of the engine under different conditions. Intake | outlet temperature sensors are installed,Within the housing of the air cleaner box or regulator,The air flow meter or an intake manifold,Used to detect the temperature of the engine inhaled air.As the intake air temperature changes will affect the air density,The hotline, hot film cooling strength and the degree of atomization of the mixture have an impact,Intake air temperature sensor,Provide a signal to correct this effect.
Humidity sensor, as an important chemical sensor, which is widely used in fields of warehousing, industry production, and process control, environmental monitoring, home appliances and meteorology etc. inner: plastic foam outside: carton
1.Wide operating temperature range: -20 to +300íµ 2.Dielectric strength: 1, 500v ac for one second 3.Short thermal response time in water, high stability in moisture 4.Suitable for use in high-temperature and moisture environments 5.High accuracy, small dimensions, different tolerancr available , cost-effective 6.Ul approval , rohs compliant 7.Customized specifications are welcome 8.Climatic category:iec60068-1 9.Max power:at 25íµ=50mw 10.Resistance tolerance ú¦ía1%í½ía10% 11.Insulation resistance: í²100mª+ 12.Dissipation constant:min. 3mw/íµú¿still airú¬ 13.Thermal time constant : 30 seconds max (still air) 14.Moisture resistance:(40íµ 95% rh)1000 hours
1.Wide operating temperature range: -20 to +300íµ 2.Dielectric strength: 1, 500v ac for one second 3.Short thermal response time in water, high stability in moisture 4.Suitable for use in high-temperature and moisture environments 5.High accuracy, different tolerancr available , cost-effective 6.Ul approval , rohs compliant 7.Customized specifications are welcome 8.Climatic category:iec60068-1 9.Max power:at 25íµ=350mw 10.Resistance tolerance ú¦ía1%í½ía10% 11.Insulation resistance: í²100mª+ 12.Dissipation constant: min.3mw/íµú¿still airú¬ 13.Thermal time constant : 15 seconds max (still air) 14.Moisture resistance:(40íµ 95% rh)1000 hours
1.Wide operating temperature range: -20 to +125íµ 2.Dielectric strength: 1, 500v ac for one second 3.Suitable for use in low and high-temperature and moisture environments 4.High accuracy, different tolerancr available , cost-effective 5.Ul approval , rohs compliant 6.Customized specifications are welcome 7.Climatic category:iec60068-1 8.Max power:at 25íµ=60mw 9.Resistance tolerance ú¦ía1%í½ía10% 10.Insulation resistance: í²100mª+ 11.Dissipation constant:min. 3mw/íµú¿still airú¬ 12.Thermal time constant : 20 seconds max (still air) 13.Moisture resistance:(40íµ 95% rh)1000 hours
1.Wide operating temperature range: -20 to +150íµ 2.Dielectric strength: 1, 500v ac for one second 3.Short thermal response time in water, high stability in moisture 4.Suitable for use in low and high-temperature and moisture environments 5.High accuracy, different tolerancr available , cost-effective 6.Ul approval , rohs compliant 7.Customized specifications are welcome 8.Climatic category:iec60068-1 9.Resistance tolerance ú¦ía1%í½ía10% 10.Insulation resistance: í²100mª+ 11.Dissipation constant:min. 2mw/íµú¿in airú¬ 12.Thermal time constant : 3seconds max ( in water ) 13.Moisture resistance:(40íµ 95% rh)1000 hours.
1.Wide operating temperature range: -20 to +200íµ 2.Dielectric strength: 1, 500v ac for one second 3.Short thermal response time in water, high stability in moisture 4.Suitable for use in low and high-temperature and moisture environments 5.High accuracy, different tolerancr available , cost-effective 6.Ul approval , rohs compliant 7.Customized specifications are welcome 8.Climatic category:iec60068-1 9.Resistance tolerance ú¦ía1%í½ía10% 10.Insulation resistance: í²100mª+ 11.Dissipation constant:min. 2mw/íµú¿in airú¬ 12.Thermal time constant : 12seconds max ( in water ) 13.Moisture resistance:(40íµ 95% rh)1000 hours.
1.Wide operating temperature range: -20 to +105íµ 2.Dielectric strength: 1, 500v ac for one second 3.Short thermal response time in water, high stability in moisture 4.Suitable for use in low and high-temperature and moisture environments 5.High accuracy, different tolerancr available , cost-effective 6.Ul approval , rohs compliant 7.Customized specifications are welcome 8.Climatic category:iec60068-1 9.Resistance tolerance ú¦ía1%í½ía10% 10.Insulation resistance: í²100mª+ 11.Dissipation constant:min. 5mw/íµú¿in airú¬ 12.Thermal time constant :85seconds max ( in water ) 13.Moisture resistance:(40íµ 95% rh)1000 hours
Applications: H2,3,4 humidity and temperature transmitters are designed for environment monitoring and controlling in industrial, commercial and other buildings. These transmitters can be used for: Humidity and temperature monitoring of supply, exhaust and return air(H2, duct mount) Humidity and temperature monitering in critical environment such as outside air(H3, outside mount) Other applications of immersion humidity and temperature monitoring(H4, separate probe) Features: High performance digital sensors and circuits, ensure accurate measurement and temperature compensation Good long term stability and reliability 100% field changeable sensors, no re-calibration needed Fast response Multiple output signals selectable Industrial design, SS probe and sintered filter High protection rate to IP65 Specifications: Relative Humidity: Sensor: Capacitance polymer Range: 0~100%RH Output: 4~20mA /0~10VDC/RS485 Accuracy: 2%,3%RH(25ípC,20~80%RH) Hysteresis:
Model: ghpp6250 Package: sop14 Pressure range: 20kpa - 250kpa Pressure type: absolute pressure Applications: compressed natural gas pressure (cng) / engine control Remark: for more details, pls contact me(sennie) directly. Export cartons
Product list : 54 (jp54) . jet a1, diesel fuel en590 (ulsd 10 ppm) 50 ppm, d6 fuel oil. diesel gas d2 oil lng. lpg, light cycle oil (lco), gasoline 72,76,91,93,95 . pet coke, automotive gas oil (ago). tar oil mazut m100 . blend crude oil, condensate gas, hydrocarbon gas . urea 46% prilled & granular, bitumen grades: 40/50, 60/70 & 80/100 road bitumen, roofing bitumen, construction bitumen .bituminous emulsion, polymeric bituminous binder, bituminous binders according to pg.