Transformer Grade-h insulation amorphous alloy transformer 10kv-35kv 30kva-2500kva This product is another novelty developed by employing proven techniques from both both united state and china on the basis of our company's successful production of model sg10 grade-h insulation unrestricted venting dry-type transformer. It lowers the no-load loss and open-circuit loss intensively, and is of superior performance, thus it is currently the state-of-the-art dry-type transformer in the world. This product is safe, reliable, environment friendly and energy saving, and can go deep into the load center and is applicable to modern city's high-density and heavy-load developmental needs. High temperature resistant liquid-immersed transformer 10kv 30kva-3150kva 35kv 50kva-31500kva
Have four number 33 kva used transformer to sell in working condition. Crompton Greaves, India, 1995 model.
Trutech Products owns the vast industry experience and well-aware of the need of todays society. We are engaged in designing and manufacturing a wide range of transformers including Control, Step-down, Three-phase, Isolation, Special Purpose, Auto Transformer, etc. Our models are distinguished from one another in size, shape and volt rating to work on different applications and industries. Backed by a talented and experienced team of engineers, we have always delivered up-to-the mark solution to our clients that fit into their budget and deliver them guaranteed results. Being the most progressive Transformer Manufacturers in India, we make sure to perform all the quality tests before performing all the safety and standard test before sending it for the shipment. Our transformers are highly demanded in commercial as well as industrial sectors. If you want the same or look for some more details, be in touch with our customer executives that answer all your queries and guide you the right solution that matches your requirements.
Distribution Transformers, Power Transformers, Furnace Transformers, Rectifier Transformer
ALL KIND OF TRANFORMERS
Electrical laminated wood is mainly used for transformers; it is also the insulation material and support material of mutual inductor. Besides, it can be used to make winding clamping plate, iron core plate, trapezoidal plate and clamping device. And it has many advantages, such as proper specific weight, high mechanical strength, good compatibility with transformer oil and easy machining. In addition, its dielectric constant is close to that of transformer oil and the insulation coordination between them is proper. It can be used in transformer oil under 105â?? for a long time. Electrical laminated wood sheet is widely used in manufacturing some devices for oil-filled transformer, such as upper and lower pressure plate, lead bracket and iron yoke cushion block. And it is used to make clamping device in mutual inductor. It can replace steel plate, insulation paper board, epoxy paper board and epoxy fiberglass board, which can lower the weight of the transformer and the cost of materials. It has been recognized to GB/T20634 or IEC61061.
TRANSFORMER
TRANSFORMER
We supply all the types of Transformers per the desired applications and also maintain the international quality standards
Gun Metal Gate Valve (Transformer Oil) Pressure Rating : PN-10 Material : Gun Metal, Bronze Description : Screwed in bonnet, inside Screw, Non-rising Stem Ends : Flanged, Mixed End Operator : Hand wheel Item Code : GM000186 Size : 15mm Notes : Available Valve Size PN-10 15mm to 250mm PN-16 15mm to 250mm
Overview In the process of semi finished and finished production of power transformers, before the newly installed transformers are put into operation and according to the state Grid's preventive test rules, it is required to test the transformer's turn ratio or voltage ratio regularly.The traditional variable ratio bridge operation is tedious, the reading is not intuitive, and the necessary conversion, the test result is only one phase change ratio value.The transformer transformer ratio tester overcomes the shortcomings of the traditional transformer ratio bridge test, the screen uses a large screen high resolution LCD screen, convenient to use in the field, with Chinese menu prompt function, simple and intuitive operation, a complete three phase change ratio test, test speed, high accuracy. Technical parameter range 0.910000 The accuracy of reading 0.1 2 words or equal to 500 reading 0.2 2 words 500 3000 Reading 0.3 2 words 3000 The resolution of the 0.9 9.9999 0.0001 100 999.99 0.01 10000 and above 1 10 99.999 0.001 1000 9999.9 0.1 Working power supply AC220V 10 50Hz Instrument weight 3.5kg The use of temperature 10 50 Overall dimensions 260mm l 200mm W 160mmH Relative humidity 90 no dew Feature Full three phase sinusoidal inverter output, the output voltage is automatically adjusted, with soft start, soft stop function, so the test speed is fast, high precision Three-phase transformer, single-phase transformer, PT, Z type transformer ratio, group, polarity test function Blind test function, that is, variable ratio and group test when high and low pressure connection mode is not known; CT variable ratio polarity test function Angle difference test function for single-phase test Tap position can be tested up to 197
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter 1. Temperature: 2. Relative humidity 3. Rated Primary Current:5-5000A 5A,1A 4.Rated secondary current:5 1A 5 Accuracy Class 0.05S 6. Allow long-term work under the rated current; More than120A across the core. Precautions: 1. The current of standard CT and tested CT must be the same in CT calibration. 2. Follow the given wiring diagram strictly. 3. Test whether the load box is accurate or not before calibrating the transformer. 4. Forbid secondary winding opening during the calibration. 5. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. 6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Transformer up to 33 kv & 10 mva ratings Depending on customers requirement
Input;110-220v Ei19-ei133
110ACV to 12ACV 220-250ACV TO 12ACV US/EUR/AUS three standard products MOQ:100 EA Package: carton
EQUINAS TFO 60u High Quality Un-Inhibited Transformer Oil EQUINAS TFO 60u is a high-quality un-inhibited insulating oil with very good dielectric properties and oxidation stability intended for transformers, switchgears, and other electrical equipment. Transformer Oil is a series of products blended using highly refined mineral oil and a selected antioxidant. It is designed for insulating and cooling transformers, oil-immersed switchgear and other electrical insulating applications. Does not contain harmful polychlorinated biphenyls (PCBs). Applications: Used as an insulating oil in transformers, switchgear, inductors, condensers, transducers, and similar equipment, also at low temperature in outdoor use It insulates current-carrying parts from each other and from ground, carries away heat, prevents glow discharges, extinguishes electric arcs in switchgear, and impregnates insulating materials Features and Benefits: Excellent insulating properties High dielectric strength (1) Low power factor Resists oxidation and deposit formation Excellent low-temperature properties Compatible with materials used in transformers Does not contain any PCBs Meets or exceeds the IEC 60296 Packages size: Available in drums and flexibags Health and Safety: Based on available information, this product is not expected to produce adverse effects on health when used for applications referred to above and the recommendations provided in the Safety Data Sheet (SDS) are followed. The SDS is available upon request through our sales contact office. This product should not be used for purpose other than the applications referred to above. If disposing of used product, take care to protect the environment, follow the local rules and regulations of your local Authority.
EQUINAS TFO 60i High Quality Inhibited Transformer Oil EQUINAS TFO 60i is a high-quality inhibited insulating oil with very good dielectric properties and oxidation stability intended for transformers, switchgears, and other electrical equipment. Transformer Oil is a series of products blended using highly refined mineral oil and a selected antioxidant. It is designed for insulating and cooling transformers, oil-immersed switchgear and other electrical insulating applications. Does not contain harmful polychlorinated biphenyls (PCBs). Applications: Used as an insulating oil in transformers, switchgear, inductors, condensers, transducers, and similar equipment, also at low temperature in outdoor use It insulates current-carrying parts from each other and from ground, carries away heat, prevents glow discharges, extinguishes electric arcs in switchgear, and impregnates insulating materials Features and Benefits: Excellent insulating properties High dielectric strength (1) Low power factor Resists oxidation and deposit formation Excellent low-temperature properties Compatible with materials used in transformers Does not contain any PCBs Meets or exceeds the IEC 60296 Packages size: Available in drums and flexibags Health and Safety: Based on available information, this product is not expected to produce adverse effects on health when used for applications referred to above and the recommendations provided in the Safety Data Sheet (SDS) are followed. The SDS is available upon request through our sales contact office. This product should not be used for purpose other than the applications referred to above. If disposing of used product, take care to protect the environment, follow the local rules and regulations of your local Authority.
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter Temperature -5 40 Relative humidity 80% Rated Primary Current 5-5000A 5A,1A Rated secondary current 5A 1A Accuracy Class 0.05S Allow long-term work under the rated current; More than120A across the core. Precautions The current of standard CT and tested CT must be the same in CT calibration. Follow the given wiring diagram strictly. Test whether the load box is accurate or not before calibrating the transformer. Forbid secondary winding opening during the calibration. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
We can supply solar transformers ideally suited for large MW scale solar PV plants. Bullet Points - . Inverter duty Solar transformers, suitable for solar load profile . Multi-winding (2 to 6 windings), oil-filled or dry type. . 2MVA to 12.5MVA, LV Side: 0.35kV to 0.69kV, HV Side 3.3kV to 33kV . Low-loss, with Aluminum or Copper winding. . Electrostatic shield between LV and MV Winding. For more details please contact us.
Control transformers are mostly used for industrial applications where electromagnetic devices are used such as solenoids, contactors and relays. Also control transformers can be utilized in industrial electrical applications for regulating voltages through electrical and electronic circuits. We make wide range of control transformers with E-I Lamination core and with various termination styles to suit for customer applications either single phase or Two phase or Three phase as per customer requirements . We provide termination with lead wires, terminal blocks, Din rails, solder points, screws, and terminal connectors. We can provide EI transformers up to 10kVA. We can provide with electrostatic shields, Thermal protector switches and circuit breakers. Features Insulation Class as per UL/IS (A,B,F,H) C and L clamps are provided according to specifications. High quality Terminal blocks are provided. High quality XLPE leads wires used. Low loss EI stampings used for high efficiency. High quality hardware used. Glass filled Nylon Bobbins used. Flame retardant insulation tapes used inside. High quality insulation used. Fiber glass sleeves used for external wires. Compact in space Cost effective Particularly well suited for resin cast Less in weight UL Approved Standards We follow IS11171. Compatible to IEC61558-1 We can provide UL 5085-1 and UL 5085-2 Applications Used in converters, inverters, instruments and power supplies. Used in many types of machines and accessories. Used in electronic sensing circuits. Used in voltage stabilizers. Used in power conditioning equipments. Used in Rectified Modules