Scope Grease similar viscometer applicable standards: sh/t0048 Grease similar viscosity meter with automatic capillary viscosity meter samples of similar viscosity, mainly suitable for grease. The viscosity of the grease at a certain temperature as the shear rate and becomes variable, called a similar viscosity. The sample was subjected to pressure is designed and made as per a spring acting on the ram within the sample tube, while the outflow from the capillary, the relaxation of the spring, a pressure within the tube is gradually decreased, it can be obtained under similar viscosity values in the series of average shear rate. Features 1. Capillary viscometer, the structure is reasonable and compact, with three variable speed; 2. The magnetic transfer medium circulation pump, no noise; 3. Stainless steel medium bath body; 4. Microcomputer temperature controller, digital display, accuracy of ± 0.5 ° c; 5. Hermetic compressor refrigeration, to ensure the supply of cold; 6. Split structure, convenient to move. Technical parameters 1. Control the temperature: room temperature to -35 ° c ± 0.5 ° c (other temperature optional); 2. Modes of operation: compressor refrigeration cycle, digital temperature control; 3. Temperature control mode: pid temperature control; 4. Power supply:ac220v± 10%, 50hz.
Scope Applicable standards: astm d1831, sh/t0122. Provides an indication of shear stability of lubricating greases by testing the change in worked penetrations after two hours in the roll stability tester. The instrument used in determination of grease consistency changes in the roller testing machine after work, with mechanical shear stability judgment of grease. Features 1. Idler retaining ring control drum work properly; 2. The bottom is equipped with a drive motor, so that speed is maintained at 155 ~ 180r/min; 3. Microcomputer temperature controller, digital display, accuracy ± 5 °c pt100 sensors; 4. Digital timer, record work time with the wind sounded the alarm. Technical parameters 1. Applicable standards: astm d1831 sh/t0122; 2. Heating method: electric coil heating machine power 1000w; 3. Working power: ac220v/50hz, temperature control range of 21 ~ 38°c; 4. Motor speed: 155 ~ 180r/min; 5. The unit of work: unit 2.
Scope Applied standards: gb/t269-91?iso2137-85?astmd217-82?ip50-79 Application range: it’s applied to the viscosity of lubricating grease and malthenes (vaseline) also used to test the materials like solids, particle and powder colloid and froze materials as well as the food raw materials like cream, carbohydrate gum, butter and barmy cream, etc. Features 1. It can allow the test in a different direction, and can even be used in a constant temperature water bath; 2. With digital display depth measuring mechanism, easy to use, good repeatability and high accuracy; 3. Bracket move fast and fretting two kinds of speed, ease of test operation of the tip of the needle at the surface of the sample; 4. It has a table level adjusting mechanism, and easy to adjust; 5. With manual release pin into pieces of bodies, to ensure that in the not automatically controlled release, still normal operation. Technical parameters 1. Time controller Control range: 0-9 minutes and 59 seconds; Control time accuracy: ± 0.1 seconds; 2. Maximum measurable penetration: 620; 3. Standard cone: 102.5g (with gb / t requirements); 4. Standard ram: 47.5g (with gb / t requirements).
Scope This product is to simulate the atmosphere composed of tiny droplets of salt spray dispersion environmental equipment, are widely used in electronics, electrical and automotive, aerospace, mobile communications, motorcycles, plastics, machinery parts, electronic components, metal surface of the material, in whole or protective layer salt spray corrosion test. Features 1. Its key components imported components, low failure rate, good stability; 2. It innovative use of water detection technology, eliminating the inconvenience of artificial water; 3. It using pid temperature control technology, precise temperature control; 4. It with glass viewing window, good visibility.
Scope The applicable standard: sh/t0325, astm d942 The applicable range: using oxygen bomb method to determine the oxidation stability of grease. Features 1. Integrated design, easy operation and maintenance; 2. Pid temperature control temperature control system, high precision and stable; 3. Automatic timing, alarm system; 4. The results of the double bomb, to facilitate the operation of parallel experiments. Technical parameters 1. The applicable standard: sh/t0325, astm d942; 2. Input voltage: ac220v ± 10%, 50hz; 3. Measuring range: room temperature -200°c; 4. Heating power: 1.8kw; 5. Temperature control accuracy: ± 0.5 °c, 113 ± 3°c; 6. Dimensions: 540 × 380 × 490mm.
Scope Petroleum products vacuum distillation analyzer is based on national standards gb / t9168 "petroleum products - determination of distillation under reduced pressure" design, manufacture. For the determination of the maximum temperature of the liquid reaches 400 ?, can be partially or completely evaporated boiling range of petroleum products under reduced pressure. Features Equipment and inputs by the host refrigeration apparatus of two parts. Host by the bath, temperature control portion, glassware, balance tank, the pressure regulating system, solenoid valves, electric heaters and other components. Its main features are as follows; 1, the main instrument is compact, attractive appearance, easy to operate, bath and end table made of stainless steel, corrosion resistance. 2, bath temperature by a digital temperature controller temperature control, temperature control table can visualize circulating water temperature, and can accurately control the temperature. 3, by the vacuum pump, pressure regulating system pressure system, solenoid valves, balance tanks and other components, make the pressure constant within a predetermined range. 4, the flask was heated furnace using a parallel structure, uniform heating, electric can adjust up and down, and with a fan to cool it quickly. 5, into the cold trap by the refrigeration apparatus cooling, convenient and reliable. Technical parameters 1, power: ac220v ± 10% 50hz 2, input power: 1900w host instrument into refrigeration 300w 3, the water bath temperature range: room temperature ~ 99.9 ? 4, temperature control accuracy: ± 2 ? 5, adjusting the pressure range: ac10 ~ 220v 6, pressure adjustment range: 1mmhg ~ 4mmhg 7, the outer shape dimensions: 720x420x680mm
Scope This instrument conforms to sh / t0169 standard Features 1, imported brand compressor, unique metal cold bath, no alcohol and so do the media, cooling speed, good cooling effect. 2, using precision pid temperature control technology, high-precision temperature sensor, temperature control and accurate. 3, the use of integrated design, easy operation and maintenance. Technical parameters 1, temperature range: room temperature -40 ? ± 0.5 ? 2, power supply: ac220v ± 10% 50hz 3, the cooling bath: a container capable of accommodating a sufficient amount of the cooling medium, the freezing point of the solvent can be maintained below 5 ? constant temperature. 4, the outer tube: pyrex test tube, 60mm × 250mm, with a rubber inner tube sese live in the lower part there is a cork ring to the inner support tube 5, inner tubes: heat-resistant glass tube: 45mm × 240mm, with a thermometer and stirrer can put two holes rubber match. 6, stirrer: ring blender glass or other inert material, so that from the thermometer with a diameter of about test tube wall into equidistant, you can use mechanical agitation.
Scope The instrument adopts the viscosity method to measure the molecular of polymer, the instrument has the characteristics of high degree of automation, good repeatability of test results, the measurement method of polymer molecular weight, polymer viscosity method is one of the most commonly used method. Features 1, computer control, man-machine friendly operation interface, prompt input operation 2, the instrument of the experimental process is fully automated, automatic extraction, automatic detection, automatic cleaning, automatic drying, no manual participation 3, 2 independent cleaning control system, it can also be independent of the operation of the experiment 4, double tube detection, but also can be asynchronous detection 5, the software prompts the operation, the operation is convenient, the measurement and the data processing cycle is short, the experiment precision is good Technical parameters 1, the detection principle: determination of polymer viscosity method 2, the detection range: 103 to 107 3, the control mode: computer control 4. Detection: automatic detection 5. Installation: program-driven 6, power: ac220v ± 10v 50hz ± 5% 7. Overall size: 700 × 430 × 700mm
Scope Petroleum products copper corrosion tester for gb / t5096, iso2160, astm d130, ip154 "petroleum products copper corrosion test method" determination of aviation gasoline, jet fuel, motor gasoline or has reye's vapor pressure of not more than 124kpa (900mmhg) other hydrocarbons, solvent oil, diesel oil, distillate fuel oil, lubricants and other petroleum extent of corrosion products on the copper. Features 1, the operating parameter set with the keyboard. 2, intelligent control system, touch the button to set, high brightness lcd dot matrix english display. 3, the test bath with accurate temperature control of the metal bath, completely avoid evaporation of water bath and oil bath arising inconvenience. 4, copper corrosion test time can be set and alarms. 5, measurement and control system has a self-diagnostic function. Technical parameters 1, the metal bath thermostatic control range: 40-200 ?, 2, temperature accuracy: ± 0.2 ? 3 heating power: 1200w 4, metal thermostatic bath can withstand the test pressure 0.7mpa. 5, automatic timing: 0-599min (keyboard settings, increment 1 min) 6, the test bath: to place the three trials and three test tubes elastomer simultaneously
Scope Petroleum products copper corrosion tester for gb / t5096, iso2160, astm d130, ip154 "petroleum products copper corrosion test method" determination of aviation gasoline, jet fuel, motor gasoline or has reye's vapor pressure of not more than 124kpa (900mmhg) other hydrocarbons, solvent oil, diesel oil, distillate fuel oil, lubricants and other petroleum extent of corrosion products on the copper. Features 1, with integrated design, easy operation and maintenance 2, the use of pid temperature control temperature control system, temperature control and high precision, stable 3, using a water bath or oil bath heating, heating speed, good stability 4, with a standard swatch us imported to meet the test requirements than 5, imported omron temperature control system, temperature of the system with expert school policies 6, using the experimental oxygen bomb storage box for easy storage and management of oxygen bomb Technical parameters 1, power supply voltage: 220v ± 10%, 50hz; 2, temperature range: room temperature ~ 100 ? arbitrarily set; temperature accuracy: ± 0.2 ?; 3. Temperature control mode: import omron smart thermostat system; 4. Timing: automatic chronograph, 1 minute to 24 hours in any setting; 5, the detection unit: 6; 6, oxygen bomb storage: configure a dedicated oxygen bomb storage warehouse, and instrument host integration design; 7, ambient temperature: room temperature ~ 35 ?; 8, relative humidity: =85%; 9. Total power consumption: less than 1800w
Scope Jet fuel silver sheet corrosion detector in accordance with national petrochemical industry standard sh / t0023 requirements "jet fuel silver sheet corrosion test method" under the design and manufacture for assessing corrosion tendency of jet fuel for aviation turbine engine fuel system components silver . Features 1, with integrated design, easy operation and maintenance 2, the use of pid temperature control temperature control system, temperature control and high precision, stable 3, using a water bath or oil bath heating, heating speed, good stability 4, imported omron temperature control system, temperature of the system with expert school policies Technical parameters 1 power supply: ac220v ± 10%; 50hz. 2, sheng-like holes: 4. 3, measuring the number of samples: 4. 4, temperature range: room temperature ~ 100 ?. 5, temperature accuracy: ± 1 ?. 6, the temperature display: digital display. 7, the temperature sensor: industrial platinum resistance, sub-degree no. Pt100. 8, timing and control the range of: 0.01 seconds to 99 hours. 9, the time display mode: digital display. 10, heating: electric heater. 11, heating power: two steps, temperature control heating power 600w; auxiliary heating power 1000w. 12, ambient temperature: -10 ? ~ + 35 ?. 13, relative humidity: =85%. 14 total power consumption: less than 1800w
Scope Copper, silver strip corrosion tester is designed and manufactured according to astm d130, iso 2160, ip 154, ip 227, sh / t0023, gb / t5096 standards. Features 1, with integrated design, easy operation and maintenance 2, the use of pid temperature control temperature control system, temperature control and high precision, stable 3, using a water bath or oil bath heating, heating speed, good stability 4, imported omron temperature control system, temperature of the system with expert school policies Technical parameters 1, the working mode: digital temperature control, four-unit; 2, temperature range: room temperature ~ 100 ± 0.5 ? 3, power supply: ac220v ± 10% 50hz
Scope Crude oil and fuel oil precipitate tester for pressing gb / t6531-86 to determine the content of crude oil and fuel oil precipitate "crude and fuel oils precipitate assay (extraction method)" is used for extraction with toluene. This standard is equivalent to international standards iso3735-1975 "crude and fuel oils precipitate assay (extraction method)", crude and fuel oils precipitate analyzer can be programmed to control its heating power. Features 1, the instrument uses dual electric stove, can work independently; 2, the instrument uses 8-bit microcontroller control; 3. The instrument uses three semi-liquid crystal display; 4, the instrument has mains compensation; 5, the instrument automatically controlled heating power; Technical parameters 1, the heating temperature range: room temperature ~ 400 ?; te00000000000mperature accuracy: ± 0.5 ?. 2, the equivalent output voltage adjustable value: 0 ~ 220v 3, electric heater power: 1000 w * 2 4, power: ac 220 v ± 10v, 50 hz ± 1hz
Scope Total precipitate residual fuel oil tester, according to sh / t0701 and sh / t0702 "residual fuel oil precipitate total assay (aging, hot filtration)" standard design and manufacturing. This method is applicable to the determination of 100 ? viscosity of less than 55mm2 / s of residual fuel oil and residue containing components reconciling get distillate fuel oil in total deposits. Features 1, the petrochemical sh / t0701 and sh / t0702 two instruments integrated into one instrument, aging and hot filtration, using a single instrument completed. 2, the instrument uses imported glass fiber filter, filter weighing accuracy is poor. 3, can simultaneously detect two samples, but also do parallel test, easy to operate. 4, the use of digital temperature controller, temperature control accuracy up to ± 0.5 ?, the temperature display and intuitive, accurate readings. 5, time use digital timer, time up 99h99m99s. 6, vacuum up 40kpa ± 2 kpa, vacuum degree of precision by the gauge display, precision vacuum pressure regulating valve 7, aging bath molding metal bath, safety, environmental protection, do sample unit to operate two holes. 8, the instrument uses metal bath replacement steam generators, the operation more secure, convenient and environmentally friendly. Technical parameters 1, the applicable standards: sh / t0701 2, the working environment: relative temperature: 0 ~ 45 ? 3, humidity: =80% 4, temperature: digital pid temperature controller 5. Timing: digital timer 6, temperature range: room temperature ~ 100 ? 7, temperature control accuracy: ± 0.5 ? 8, vacuum pressure: precision gauge shows 9, the working mode: two units 10, total power: 2000w 11, working power; ac220v ± 10% 50hz
Scope Distillate fuel oil oxidation stability tester side given instrument (accelerated method) according to sh / t0175-94, astmd2274 and other standards to determine the initial boiling point of not lower than 175 ?, 90% point distillation temperature no higher than 370 ? of middle distillate fuels inherent stability and performance of the oil. I.E., in the case of an active metal surface and the water or dirt and other environmental factors do not exist, the sample is exposed to the atmosphere in the ability of anti-change. Features 1, the fixed value regulator valve to provide a constant flow of oxygen test. 2, thermostatic bath, large capacity, good insulation properties, and can make six samples tested. 3, oxidation tube with radial clamping, easy operation and reliable. 4, the camera obscura after the oxidation test tube directly into which were cooled at room temperature 5, sample oxidation time automatic control, when the alarm system. 6, the instrument uses metal bath, heating speed, good stability, environmental protection Technical parameters 1, oxidation flowmeter: six oxidation test flow meter can be adjusted individually, the test flow rate: 50 ± 5ml / min. 2, constant temperature bath: the use of fld metal bath. 3, the thermometer: in line with gb / t514-83 standard, wlh-33c, 50-100 ?, 0.5 ? indexing rod 4. Temperature control mode: automatic heating, automatic temperature control 5, temperature accuracy: 95 ± 0.2 ? 6, oxidation tube: borosilicate glass, in line with sh / t0175-94 standard 7, electric heaters: when the main heater 220v 2500w, auxiliary heating 800w. 8, the regulator valve oxidation: oxidation is the oxidation stability, in front of the flow meter with regulator valve
Scope UV fluorescence sulfur analyzer is based on UV fluorescence measurement principle and the development of computer technology combined with a new generation of precision instruments, is currently the most advanced of the total sulfur content tester, in line with ASTM D5453, SH / T 0689 and other standards, the instrument is National total sulfur content of refined oil arbitration standards. Now widely used in the determination of total sulfur content of crude oil, hydrocarbons and fuel, petroleum, plastics, petrochemicals, food and so on. Measurement principle instrument uses ultraviolet fluorescence method, when the sample is introduced into the pyrolysis furnace, cracking occurred sample oxidation of sulfide which quantitatively converted to sulfur dioxide, carried by a carrier gas, off which the water through a membrane dryer, into the reaction chamber, sulfur dioxide absorbing ultraviolet light energy into an excited state of sulfur dioxide (SO2 *), the fluorescence emission of sulfur dioxide when SO2 * to return to a stable state, the energy released by a photomultiplier tube to receive, and then the micro-current amplifier, computer data processing, the amount of reaction with sulfur dioxide emission intensity is proportional to the amount of sulfur dioxide and total sulfur content in the sample is proportional, so the content of the sample can be determined by measuring total sulfur emission intensity. Features 1, computer-controlled operation, enabling interactive, data, peak shape can be automatically stored print. 2, the operating software can be connected with LIMIS system, automatic data transmission. 3, the instrument uses the new quartz pyrolysis tube, the injection volume can be increased to reduce measurement errors, increase the sensitivity of the instrument, higher repeatability. 4, cooling fans, automatic switch, eliminating the need to wait for the shutdown to finish samples trouble, saving time and effort. 5, darkroom system uses the latest technology, the key components imported detecting element to improve the detection accuracy and sensitivity of the instrument. 6, equipment imported membrane dryer to absorb , eliminating the need to frequently replace magnesium perchlorate of trouble, while reducing the leakage problem. 7, using computer control of temperature, improve the instrument precision temperature control, and difficult to over-temperature. 8, using air instead of water cooling, saving water resources. 9, can be adjusted to take existing calibration curve calibrated using a standard sample after sample analysis. Technical Parameters 1, in line with standards: ASTM D5453, SH / T 0689 and other standards 2, measuring range: 0.2mg / L ~ 10000mg / L ~ percentage 3. Air source: Argon: 99.999% Oxygen: 99.999% 4, sample status: solid, liquid, gas (with corresponding injector) 5, temperature range: room temperature ~ 1100 ? ± 3 ? 6, repeatability error: 0.2mg / L=X
Scope Standard: sh / t0123 Sample in 95 ° c, which leads to constant dry air, test 312h, by measuring changes in growth and sedimentation value of the sample value 100 ° c kinematic viscosity. Features 1, extreme pressure lubricant oxidation characteristics analyzer using intelligent temperature controller with a microprocessor, with self-tuning, self-diagnostic function, pid three parameters to adjust the temperature, auxiliary heating automatically turn off, thus high precision temperature control, performance stable and reliable. 2, extreme pressure lubricant oxidation characteristics analyzer with automatic timing device, without manual timing, when the alarm. 3, extreme pressure lubricant oxidation characteristics analyzer using precision flowmeter control systems, flow can be set with the user. 4, extreme pressure lubricant oxidation characteristics analyzer uses an integrated setting, operation and maintenance simple and convenient. Technical parameters 1, temperature range: room temperature ~ 150 ° c, temperature control accuracy: 0.1 °c. 2, temperature control mode: intelligent temperature control thermostat. 3, power supply: ac220v 50hz. 4, the heating method: oil bath. 5, the timing device: automatic timer. 6, the flow control: precision flowmeter.
Carbon extraction from pulverized fuel ash / pulverized fuel ash sorting As there is carbon in fly ash, which is not only waste the energy, but also seriously affect the quality of fly ash. If the content of carbon in fly ash is more than 8 percent, it will affect the quality control of the cement or concrete, for the superior fly ash, the maximum content should be less than 4 percent. The carbon maximum in the fly ash is 8percent according to the gb standards in our country.This process refines the carbon from fly ash on the basis of thermoelectricity and electrical conductivity of the carbon by feeding, scattering, drying, vibrating, dust collecting, magnetic separation, electric separation and a series of processes. This electric separator has improved the internal structure and equipped with heating system on the basis of the advantages of other electric separator, to achieve better effect on fly ash separation.Carbon content of fly ash will be under 7 percent. The process achieve the automatic production, there is dust collecting equipment in every link to reduce the dust pollution.The technology is our company’s patent, patent number: 201110286037.1, 201110286091.6, 200920258609.3, 201110288262.9. Company commitment: the company has sales of pulverized arg, ash sorting has perfect after-sales service, one year warranty, life-long maintenance, thoroughly solve your trouble back at home, please rest assured purchase! Carbon extraction from pulverized fuel ash / pulverized fuel ash sorting
Scope Distillate fuel oil oxidation stability tester side given instrument (accelerated method) according to sh / t0175-94, astmd2274 and other standards to determine the initial boiling point of not lower than 175 ?, 90% point distillation temperature no higher than 370 ? of middle distillate fuels inherent stability and performance of the oil. I.E., in the case of an active metal surface and the water or dirt and other environmental factors do not exist, the sample is exposed to the atmosphere in the ability of anti-change. Features 1, the fixed value regulator valve to provide a constant flow of oxygen test. 2, thermostatic bath, large capacity, good insulation properties, and can make six samples tested. 3, oxidation tube with radial clamping, easy operation and reliable. 4, the camera obscura after the oxidation test tube directly into which were cooled at room temperature 5, sample oxidation time automatic control, when the alarm system. 6, the instrument uses metal bath, heating speed, good stability, environmental protection Technical parameters 1, oxidation flowmeter: six oxidation test flow meter can be adjusted individually, the test flow rate: 50 ± 5ml / min. 2, constant temperature bath: the use of fld metal bath. 3, the thermometer: in line with gb / t514-83 standard, wlh-33c, 50-100 ?, 0.5 ? indexing rod 4. Temperature control mode: automatic heating, automatic temperature control 5, temperature accuracy: 95 ± 0.2 ? 6, oxidation tube: borosilicate glass, in line with sh / t0175-94 standard 7, electric heaters: when the main heater 220v 2500w, auxiliary heating 800w. 8, the regulator valve oxidation: oxidation is the oxidation stability, in front of the flow meter with regulator valve
Scope Determination (drinks) volatile organic compounds, blood alcohol content detection, detection of indoor air pollutants (TVOC), flavor liquor composition analysis, transformer oil analysis, testing, high-purity gas analysis of residual solvents in pharmaceuticals, medical devices remaining in Determination of ethylene oxide. Chromatograph units are mainly used: liquor factory, other wineries, petrochemical, gas liquefaction plant, the coal industry, environmental testing, inspection station, Forensic Center, the public security system, food plants, quality inspection departments, water plants, pharmaceutical plants, detection of pesticide plants, gas plants, chemical plants, packaging plant, paint factory, honey factory, chemical engineering universities and other trace ingredients are required to use gas chromatography, liquid chromatography Features 1. Large-screen LCD English display. Easy to learn. 2. With self-diagnosis, over-temperature shutdown protection, file storage, recall, fifth-order temperature-programmed functions, with single-column automatic compensation function; to ensure the stability of the baseline temperature programmed analysis. 3. Instrument has dual packed column inlet capillary column three, three gas independent way. 4. With six independent temperature control area, after intelligent door systems, cooling is very fast; each of the gasification chamber, detector and amplifier are modular design, installation is very easy to replace. 5. Complete with a separate capillary analysis system, an independent capillary split sampler (includes a diaphragm cleaning, split and tail blowing conditioning). Optional capillary split / splitless injector. 6. Instrument equipped with a flame ionization detector, thermal conductivity detector, a flame photometric detector, electron capture detector, NPD five kinds of detectors, three detectors can be installed, the user can according to their own self-analysis requires optional , also increase the six-way injection valve, reformer devices; and to achieve detector series and parallel work. Technical Parameters Temperature Indicators 1. Temperature Area: column oven, injector, detector 2. Temperature range: room temperature on 5 ? ~ 450 ? (Increment 1 ?) 3. Temperature accuracy: better than ± 0.1 ? 4. Temperature program: Eight-order rate of 0.1 ? ~ 40 ? / min (increments of 0.1 ?)