- Design Pressure : 2.3MPa - Volume capacity : 11.5~18.5TON - Diameter : 1600~1750mm - Height : 1809~2076mm - Material : SLA360 - Standard/Certificate : ASME U¡±&¡±S¡±STAMP, KS Q ISO 9001:2009/ ISO 9001:2008
- Design Pressure : 0.6MPa - Volume capacity : 10~18 - Diameter : 1600~1750 - Height : 6730~9192 - Material : A240-304 - Standard/Certificate : ASME U¡±&¡±S¡±STAMP, KS Q ISO 9001:2009/ ISO 9001:2008.
Type 1 L-N2, L-O2, L-Ar - Design Pressure : 2.0MPa - Volume Capacity(Nm/hr) : 100~1000Nm/hr - Material : A6063S-T5 Type 2 L-CO2 - Design Pressure : 2.3MPa - Volume Capacity(kg/hr) : 100~1000kg/hr - Material : A6063S-T5
Surgical Gown LEVEL 2-LEVEL 4Blue AMMI Level 2-3 Gown Disposable Medical PP Non-woven Gown SURGICAL GOWNS � Surgical gowns are personal protective equipment used by many people in health care. Surgical gowns are used by surgeons and the surgical team for all types of procedures. Modern surgical gowns provide a breathable, protective barrier for the surgeons and all health care providers. � Surgical gowns provide a barrier protection to prevent blood strikethrough and fluid contamination. Most surgical gowns are sterile and come in a wide variety of sizes and versions. Surgical gowns can be purchased alone or within surgical packs. There are many surgical packs for frequently performed procedures. � Surgical gowns are produced non-reinforced or reinforced. Non-reinforced surgical gowns are less durable and designed for surgical procedures with low to moderate fluid contact. Reinforced surgical gowns have reinforced protection in specific critical areas for more invasive and intense surgical procedures. Surgical gowns cover and provide a barrier for important areas from the shoulders to the knees and wrists. Surgical gowns are usually made with Set-In sleeves or Raglan Sleeves. Surgical gowns come with and without a towel. Most surgical gowns are made from a fabric called SMS. SMS stands for Spunbond Meltblown Spunbond. SMS is a lightweight and comfortable non-woven fabric that provides a protective barrier. Surgical gowns are usually rated by their AAMI level. AAMI is the Association of the Advancement of Medical Instrumentation. AAMI was formed in 1967 and they are a primary source of many medical standards. AAMI has four protection levels for surgical gowns, surgical masks, and other protective medical equipment. Level 1: is used for Minimal Risk of exposure situations, such as providing basic care and cover gowns for visitors. Level 2: is used for Low Risk of exposure situations, such as during common blood drawing procedures and suturing. Level 3: is used for Moderate Risk of exposure situations, such as surgical procedures and inserting an Intravenous (IV) line. Level 4: is used for High Risk of exposure situations, such as during long, fluid intense surgical procedures.
Properties 1. Excellent transparency, outstanding resistance to aging. 2. It has good insulating properties and mechanical strength; to acid, alkali, salt has a strong resistance to corrosion; and because easy processing. Applications 1.Extruded sheets for signage, displays and building material 2.Motive parts such as tail lamps, meter covers and sun visors 3.General sundries such as tableware, kitchenware, giftware and bathroom accessories 4.Optical lenses such as sunglasses, reading glasses and camera lenses 5.Light guide panels for LCD displays 6.Other applications such as mobile phone display panels, clock covers, lighting covers/accessories, optical fibres, toys, etc.
Properties 1. Excellent transparency, outstanding resistance to aging. 2. It has good insulating properties and mechanical strength; to acid, alkali, salt has a strong resistance to corrosion; and because easy processing. Applications 1.Extruded sheets for signage, displays and building material 2.Motive parts such as tail lamps, meter covers and sun visors 3.General sundries such as tableware, kitchenware, giftware and bathroom accessories 4.Optical lenses such as sunglasses, reading glasses and camera lenses 5.Light guide panels for LCD displays 6.Other applications such as mobile phone display panels, clock covers, lighting covers/accessories, optical fibres, toys, etc.
Ultrasonic flow meter, digital fuel flow meter, oil flow meter, digital level transmitter.
The ball float liquid level controller output 4 ~ 20 ma stadard current signal and matching with the iii type electric instrument, which can realize the automatic detection , control and record for the liquid level. The liquid level transmitter is suitable for oil refining industry, chemical industry, paper making, food and pharmaceutical industries, and applicable for the medium liquid level measurement such as sewage and all kinds of exposure or pressure containers, for underground storage tanks and high-level water tank level measurement are ideal. Liquid level Working temperature:¡ª40~+60¡æ Load resistance:620¦¸ Voltage supply:24vdc Outlet joint: internal screw thread m20¡á1.5 Connecting flange:hg20592~20635£97 dn150 pn1.6¡¢2.5mpa, Other flange standards such as gb£¬hgj£¬ansi of the users indicate. Anti-explosion sign: flameproof type diibt4 Material of the float ball:0cr18ni9, ptfe Paper ctn.
Measuring range 0.05~30m Measuring accuracy ±3mm Function:Single Measurement,Continuous Measurement, Area Measurement, Data storage , Bluetooth Power Supply:Lithium Battery LCD Display
Code 95109: Easier breathing and speech with maximum comfort Features 1. Designed to have more room for easier breathing by eliminating discomforts to the nose in exhaling. 2. Keep the face mask at a distance from the lips and mouth, providing more room for easier breathing. 1. Type: Diamond shape, 3-ply, non-sterile 2. Size: M, L 3. Color: Green, blue, pink, white 4. Outer Layer: Water-repellent non-woven 5. Middle Layer: High level static filtration non-woven 6. Inner Layer: Microfilter Thermal-bond non-woven 7. Nose band: PE iron wire
Code 93100: 3-ply, non-woven material 99% BFE at 3 micron Features: Suitable for OR, ER, patient care area, oral, dental procedure, clinics, isolation, IC practices, patients and other applications. 1. Type: Flat shape, 3-ply, non-sterile 2. Size: For adults 3. Color: Green, blue, pink, white 4. Outer Layer: Water-repellent non-woven 5. Middle Layer: High level static filtration non-woven 6. Inner Layer: Microfilter Thermal-bond non-woven 7. Nose band: PE iron wire
Xl5135v-1 ac220v power supply--measuring dc voltage--voltmeter Technical index: Digit display: 1999 Operating temperature:0~40 Relative humidity:20%~80% Power supply:ac220v Installation method:inlay Tapping size:76 x 39 (mm) Dimension: (w) 79mm x (h) 42.5mm x (d) 25.5mm Resolution: 10mv Input impedance: 100mª+ Max. Input voltage:ía10v Full range:ía199.9mv.
1.General PZ96 Series power analyzer specializes in measuring the data of all kinds of AC networks, such as the currents, the voltages, the powers, the energies etc... It may be used for local display, or it is connected with the control equipment in measuring and controlling system. They are a kind of programmable analyzer. With the 4 key on the front, we can set their parameters according to the network which we measure. They have many option functions. They can be equipped RS-485 communication with Modbus-RTU protocol; or they can output analog signal. With logic input or logic output, we can realize controlling other equipment remotely They are a kind of analyzer with excellent cost performance, since they regroup the functions of traditional electric transmitter and digital meters. Therefore they are widely being used in kinds of control system, SCADA system and power management system. 2.Technical feature - Input Network: Single-phase network; 3-phase balanced network, 3-phase unbalanced, 3 wires; 3-phase unbalanced, 4 wires Measurable: 26 parameters (3I, 6U, F, 4P, 4Q, 4cos, 4E) Frequency: 45í½65Hz Voltage: AC 100V, 400V (programmable); Overload: 480V (continuous), 800V/30s; Consumption: < 0.2VA Current: AC 1A, 5A (programmable); Overload: 6A (continuous), 50A/30s; Consumption: < 0.2VA Thermal drift: 100Mª+ - Environment Work T: -10Cí½+45C Storage T: -20Cí½+70C Relative humidity: 5%í½95% (no condensation) Altitude: í_2500m 3.Options - Display (L): LED or LCD display, the brightness can be set - Communication (/C): RS485 (Modbus-RTU); 1 start bit, 8 data bit, 1 stop bit, no parity, speed (1200/2400/4800/9600/19200) - Alarm output(/J): 1 passive relay (1A/30VDC, 1A/250VAC); alarms of over voltage, low voltage and over current; The hysteresis and the delay can be set - Analog output(/M): DC4~20mA, DC0~20mA( load < 600ª+), DC0~5V,DC1~5V( load > 1kª+); Number: /M, /M3 (1 or 3 analog outputs) - Logic options(/K) 4 logic inputs and 2 logic outputs Logic Input: dry contact Input, supplied inside, optoisolator Logic output: NO-NC contact; 1A/30VDC,5A/250VAC ( to control other equipments) - Accuracy: 0.2 Note: /M and /K can not be chosen simultanously. 4. Specification 96 * 96 mm PZ96-E3 3 Phase LED PZ96L-E3 3 Phase LCD 72 * 72 mm PZ72-E Single Phase LED PZ72L-E Single Phase LCD 80 * 80 mm PZ80-E Single Phase LED PZ80-E3 3 Phase LED PZ80L-E Single Phase LED PZ80L-E3 3 Phase LCD 120 * 120 mm PZ42-E3 3 Phase LED PZ42L-E3 3 Phase LCD 144 * 144 mm PZ144-E3 3 Phase LED
The product is used to measure the pH of given aqueous sample.The Range is from 0pH to 14pH.It is given with automatic temperature sensor.
Digital panel meter Digital panel meter which is various and artistic in appearance design is used for dual slope, high precise a/d changeover circuit and high light led cassette setting specification. It is very convenient for user to fix the equipment.
We offer many kinds of industrial measuring instruments and meters, you are welcome to link to: www.Windofwest.Diytrade.Com for more information. Cartons